7
-
CAUTION: BEFORE ATTEMPTING TO REMOVE OR
REPAIR ANY PCB, UNPLUG THE POWER
CORD FROM THE A.C. SOURCE.
LOCATION OF PRINTED CIRCUIT
BOARDS
Note :
Take caution when removing flat cables to prevent any
contact problem.
Connect and disconnect the flat cables at right angles to
the connector and make sure that it is completely
secured.
After servicing the PCB, restore the flat cable and leads
to their former state.
PCB-JACK
PCB-OPE
PCB-SIGNAL
PCB-MAIN
HOW TO EXECUTE CIRCUIT BOARD SERVICE
Fig. 6
a
c
b
PCB - OPE
Fig. 7
1. PCB-OPE
1. Remove the Top Cover.
(Refer to Para. 1 of the DISASSEMBLY.)
2. Remove the Front Panel.
(Refer to Para. 2 of the DISASSEMBLY.)
3. Unfasten the one catch (a) shown in Fig. 7 and rotate
the PCB-OPE in the direction shown by arrow (b) and
remove it in the direction shown by arrow (c).
2. PCB-SIGNAL
1. Remove the Top Cover.
(Refer to Para. 1 of the DISASSEMBLY.)
2. Remove the one PCB Holder fastening screw (a) shown
in Fig. 8 and remove the PCB Holder.
3. Raise the PCB-SIGNAL upward to remove it as shown in
Fig. 8.
PCB Holder
PCB-SIGNAL
a
Fig. 8