Mitsubishi WS-48515 Service Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 81
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
Page 47
Purpose:
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
MODELS: WS-48515 / WS-55515 / WS-55615 / WS-55815 / WS-65515 / WS-65615 /WS-65815 / WS-73615
-----
-----
------
-----
Monoscope (NTSC & HD)
Video & Component Inputs
To set the height, width and linearity of the raster.
Incorrect height, width and/or linearity.
Note:
Always use the
Standard Format
when aligning Geometry and Convergence.
Preliminary:
1. DO NOT change the initial values for “#8 VLIN” in the CRT-JUNGLE Function.
2.
DO NOT exceed the following VHGT adjustment ranges:
NTSC ... from -4 to +10
HD ... from -10 TO +5
NTSC Mode
1. Supply an NTSC Monoscope signal to a Video Input.
2. Select the Monoscope as the signal source.
3. Activate the Adjustment Mode, CRT-JNGL Function.
4. Select and adjust each of the following items.
• “7 VHGT” ... so the vertical marker sum = 4
• “1 HWD” ... so the horizontal marker sum = 7
5. Save data and Exit the Service Mode.
HD Mode
1. Supply an HD Monoscope signal to the Component HD Inputs.
2. Select the Component Inputs as the signal source (Input button)
3. Activate the Service Mode, CRT-JNGL Function.
4. Select and adjust each of the following items.
• “7 VHGT” ... so the vertical marker sum = 2
• “1 HWD” ... so the horizontal marker sum = 5
5. Save data and Exit the Service Mode.
[Deflection Circuit]
14: Deflection Geometry
Height & Width Adjustment
CIRCUIT ADJUST MODE
Activate.. MENU-2-4-5-7
Function...… ..AUD IO
Item No. ……….…….VIDEO
Adjust Data ….…….ADJUST
Save Data. … ENTER
Exit …………..MENU (twice)
Page view 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 80 81

Comments to this Manuals