Summary of Contents

Page 2

10FDT CEILING CASSETTE -4way-Outline drawing (Unit:mm)R410AR410ACLASSAAAEasy checking of drain pan condition is available by removing corner lid only.

Page 3

11R410AASPECIFICATIONSThe data are measured under the following conditions(ISO-T1).Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB

Page 4

12FDTCR410AR410ACEILING CASSETTE -4way Compact (600 X 600mm)-CLASSAAAPoint3“CLEARER”Air FlowPoint4Installation WorkabilityRCN-TC-24W-ERNew shape &

Page 5

13R410AASet model nameIndoor nameOutdoor namePower sourceNominal cooling capacity (Min~Max)Nominal heating capacity (Min~Max)Power

Page 6

14Enhanced installation workabilityQuiet, Lightweight and CompactWith the FDU71, the noise level is only 37dB (low), weight is only 40kg and height is

Page 7

15Set model nameIndoor nameOutdoor namePower sourceNominal cooling capacity (Min~Max)Nominal heating capacity (Min~Max)Power consu

Page 8

16H 350H 280R410AR410ACLASSAAAFDUMDUCT CONNECTED -Middle Static pressure-FDUM 50/60/71/ 100/125/140VFOutline drawing(Unit:mm)Model FDUM50VF

Page 9

17kWkWkWAdB(A)dB(A)CMMPammkgmmkgkg(m)ømmmO/UO/USet model nameIndoor nameOutdoor namePower sourceNominal cooling capacity (Min~Max)Nominal hea

Page 10

18Outline drawing (Unit:mm)modelFDEN40,50FDEN60,71FDEN100~140a102212721572b99012401540c107013201620d215215255e210210250Dimension Table68410690135 1452

Page 11

19R410AAISO-T1(JIS)ISO-T1(JIS)Cooling/HeatingCooling/HeatingCooling/HeatingIndoorOutdoorOutdoorIndoorOutdoorHeight x Width x DepthkWkWkWAdB(A)dB(A)CMM

Page 12

2eco touch REMOTE CONTROLeco touch REMOTE CONTROLAdvanced touch screen panel with full dot Liquid Crystal displaySimple setting by tapping button only

Page 13

20Outline drawing (Unit:mm)R410AR410ACLASSAAAPiping and drain hose connection can be selected out of 4-directions and the selection makes installation

Page 14

21R410AAISO-T1(JIS)ISO-T1(JIS)Cooling/HeatingCooling/HeatingCooling/HeatingIndoorOutdoorOutdoorIndoorOutdoorHeight x Width x DepthkWkWkWAdB(A)dB(A)CMM

Page 15

22FDT FDT 100/125/140VFCEILING CASSETTE -4way-R410AR410ACLASSAAA[ INDOOR UNIT ]RC-E5RC-EX1AWiredRCH-E3 RCN-T-36W-EWireless3Phase 380-415V 50Hz, 3Phase

Page 16

23R410AAFDU 100/125/140VDFDUDUCT CONNECTED -High Static pressure-FDU 200/250VFU-FCRA[For 200/250VF]Fan control kit(100~200Pa) (option)RC-E5RC-EX1AWire

Page 17

24R410AR410ACLASSAAARCN-KIT3-EWirelessFDUM 100/125/140VFRC-E5RC-EX1AWiredRCH-E3Filter kit (option)UM-FL3EF : for 100, 125, 140external static pressure

Page 18

25R410AARemote control (Option)R410AR410ACLASSAAAFDEN 100/125/140VFRCN-E1RWirelessRC-E5RC-EX1AWiredRCH-E3ISO-T1(JIS)ISO-T1(JIS)Cooling/HeatingCooling/

Page 19

26R410AR410ACLASSAAARCN-KIT3-EWireless remote control (Option)FDFFLOOR STANDING [ INDOOR UNIT ]Micro InverterFDF 100/125/140VDISO-T1(JIS)ISO-T1(JIS)Co

Page 20

27R410AAFDC200VS(8.0HP)FDC71VNX(3.0HP)FDC250VS(10.0HP)OUTDOOR UNIT (1.5-10.0HP)Installation workabilityEnhanced installation workability thanks to the

Page 22

3Main functionsAll settings done by tapping touch screen panelOperation mode setting screenThe desired operation mode can be selected by simply tappin

Page 23

4HeatingCooling-15°C+43°C-20°C+20°C50403020100-10-20-30: Heating operation down to -20°C: Nominal heating capacity maintained at -15°C-20°C -15°CFDC10

Page 24

5Thanks to optimization of refrigeration control with use of electric expansion valve and development of new twin rotary compressors, max heating capa

Page 25

6Previous NewDue to optimization of outlet design of air flow with our new advanced technology, sufficient air flow is secured and long reach of air f

Page 26

7Duct design was simplified.Using DC motor, the most optimum air flow volume can be achieved by this automatic control. Keep the same air flow volume

Page 27

8SINGLE [OUTDOOR UNIT : INDOOR UNIT = 1 : 1]CEILING SUSPENDEDType4wayFDT4way compact (600 x 600mm)FDTCLow/Middle Static pressureFDUMHigh Static pressu

Page 28

9FDT100VF FDT125VF FDT140VF*FDU100VSVD*FDU125VSVD*FDU140VSVD FDU200VSVF FDU250VSVFFDU125VD FDU140VDFDU100VDFDU125VDFDU140VDFDU200VF FDU250VFFDUM100VNV