6 DRIVE THE MOTOR
6.1 Operation panel (FR-DU08)
6.1.1 Components of the operation panel (FR-DU08)
No. Component Name Description
Operation mode
indicator
PU: Lit to indicate the PU operation mode.
EXT: Lit to indicate the External operation mode.
(Lit at power-ON in the initial setting.)
NET: Lit to indicate the Network operation mode.
PU and EXT: Lit to indicate the External/PU combined operation mode 1 or 2.
Operation panel
status indicator
MON: Lit to indicate the monitoring mode.
Quickly flickers twice intermittently while the protective function is
activated. Slowly flickers in the display-OFF mode.
PRM: Lit to indicate the parameter setting mode.
Control motor
indicator
IM: Lit to indicate the induction motor control.
PM: Lit to indicate the PM sensorless vector control.
The indicator flickers when test operation is selected.
Frequency unit
indicator
Lit to indicate frequency.
(Flickers when the set frequency is displayed in the monitor.)
Monitor (5-digit LED)
Shows the frequency, parameter number, etc.
(Using Pr. 52, Pr. 774 to Pr. 776, the monitored item can be changed.)
PLC function
indicator
Lit to indicate that the sequence program can be executed.
FWD key, REV key
FWD key: Starts forward rotation. The LED is lit during forward operation.
REV key: Starts reverse rotation. The LED is lit during reverse operation.
The LED flickers under the following conditions.
When the frequency command is not given even if the forward/reverse
command is given.
When the frequency command is the starting frequency or lower.
When the MRS signal is being input.
STOP/RESET key
Stops the operation commands.
Resets the inverter when the protection function is activated.
Setting dial
The setting dial of the Mitsubishi inverters. The setting dial is used to change the
frequency and parameter settings.
Press the setting dial to perform the following operations:
To display a set frequency in the monitoring mode
(the setting can be changed using Pr. 992.)
To display the present setting during calibration
To display a fault history number in the faults history mode
MODE key
Switches to different modes.
Pressing the "MODE" and "PU/EXT" keys simultaneously switches to the easy
setting mode.
Holding this key for 2 seconds locks the operation. The key lock is invalid when
Pr. 161="0 (initial setting)". (Refer to the Instruction Manual.)
SET key
Enters each setting.
If pressed during operation, the
monitored item changes.
(Using Pr
. 52 and Pr. 774–Pr. 776, the
monitored item can be changed.)
ESC key
Goes back to the previous display.
Holding this key for a longer time changes the mode back to the monitor mode.
PU/EXT key
Switches between the PU mode and the External operation mode.
Pressing the "MODE" and "PU/EXT" keys simultaneously switches to the easy
setting mode.
Cancels the PU stop also.
쐃쐇
Output
frequency
Output
current
Output
voltage
When the initial setting is set.