CITY MULTI Control System
Smart ME Controller PAR-U02MEDA
Installation Manual
Prior to use, thoroughly read the instructions in this manual to use the product correctly.
Retain this manual for future reference.
Make sure that the CD-ROM, this manual, and Simple Operation Manual are passed on to
any future users.
To ensure safety and proper operation of the remote controller, the remote controller should
only be installed by qualified personnel.
For distribution to dealers and contractors
English
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Installation Manual

CITY MULTI Control SystemSmart ME Controller PAR-U02MEDAInstallation ManualPrior to use, thoroughly read the instructions in this manual to use the pr

Page 2

– 9 –• Cut out the thin-wall part on the cover (indicated with the shaded area in the right figure) with a knife or a nipper. Note:Make sure that the

Page 3 - WARNING

– 10 –6 Connect the remote controller cable to the terminal block on the top case.Connect the remote controller cable to the terminal block. * Take t

Page 4

– 11 –7 Set the M-NET addresses.* The factory setting for the rotary switches is 01.** M-NET address can be changed with or without the power being ap

Page 5

– 12 – Direct wall installation (when running the cable along the wall)• Thread the cable through the access hole at the top of the remote controlle

Page 6

– 13 – Discrepancy between the room temperature measured at the wall and the actual room temperature may occur.If the following conditions are met, t

Page 7 - 5How To Install

– 14 –Chapter 2. Initial SettingThis chapter contains information about the settings to be made at the time of installation. Please read the instructi

Page 8

– 15 –(2) Setup screenAfter completing the settings, touch the [Back] button on the [Setup] screen. The message “Collecting the information from the a

Page 9

– 16 –A password is required to access the Menu (Service) screen or some settings under the Menu (User) screen.• The initial Service password is “9999

Page 10 - 60 (2-3/8)

– 17 –*1 This setting will not become effective if the temperature sensor on the indoor unit is activated.*2 The LED indicates the operation status of

Page 11

– 18 –(1) Setup menu(a) Group settingRefer to section 1 "Initial Settings" (2) "Setup screen". (b) LOSSNAY interlockRefer to secti

Page 12 - Should not

– 1 –Chapter 1. InstallationThis installation manual describes how to install the Smart ME Controller for use with Mitsubishi Building Air Conditionin

Page 13

– 19 –(h) Telephone number (i) IC function setting1Select the indoor unit address in the [M-NET address] field. (When [Grp] has been selected, all the

Page 14 - 6 Important

– 20 –(k) Reset RC (l) AHC port name(2) Error Menu (a) Self check(max. 20 characters)WT06829X02.book Page 20 Wednesday, June 26, 2013 4:03 PM

Page 15 - Chapter 2. Initial Setting

– 21 –(a) Read the section about Test run in the indoor unit Installation Manual before performing a test run.(b) During the test run, indoor units wi

Page 16

– 22 –*1 Not for use with a generic DC power supply device.*2 “Power consumption coefficient” is a coefficient to calculate the relative power consump

Page 17 - 2 Service Menu

Please be sure to put the contact address/telephone number on this manual before handing it to the customer.This product is designed and intended for

Page 18

– 2 – CAUTION WARNING CAUTION WARNING CAUTIONPrecautions during installationPrecautions during wiringTo reduce the risk of fire or explosion, do not p

Page 19 - (f) Humidity sensor offset

– 3 – WARNING CAUTIONThe CD-ROM that is supplied with Smart ME ControllerThe CD-ROM that is supplied with the Smart ME Controller contains an Installa

Page 20 - (max. 13 numbers)

– 4 –The following parts are included in the box.(1) Field-supplied parts(2) Required tools• Flat-tip screwdriver (Width: 4-5.5 mm (5/32-7/32 in))• Kn

Page 21 - (2) Error Menu

– 5 –*1 The power consumption coefticient of the Smart ME Controller is “0.5” and that of a ME Remote Controller (PAR-F27MEA) is “0.25”.If the number

Page 22

– 6 –This remote controller is for the wall installation. It can be installed either in the switch box or directly on the wall. When performing direct

Page 23

– 7 –Occupancy sensor detects occupancy based on the temperature difference between the occupant and its surroundings.To be precise, to enhance the se

Page 24

– 8 –(2) Installation spaceLeave a space around the remote controller as shown in the figure below, regardless of whether the controller is installed