Mitsubishi MSC-GA20VB Service Manual Page 23

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 22
23
Start
Indoor unit
operates.
Outdoor unit
does not
operate.
Indoor unit
does not receive
the signal from
remote controller.
Indoor unit
operates.
Outdoor unit
does not operate
normally.
OPERATION INDICATOR
lamp on the indoor unit is
flashing ON and OFF.
Outdoor unit
operates only
in “Test run
operation”.
Indoor unit
operates, when
the EMERGENCY
OPERATION
switch is pressed.
Indoor unit
does not operate,
when the
EMERGENCY
OPERATION
switch is pressed.
Check room
temperature
thermistor.
Refer to 10-6.
"Test point
diagram and
voltage".
Refer to
"Check of
outdoor unit".
Refer to 10-5.
"Check of
remote controller
and receiver
P.C. board".
MUH/MXZ
Flash ON and
OFF at 0.5-
second intervals
Cause: Indoor/
outdoor unit
• Mis-wiring/or
trouble of
serial signal
2-time flash
Cause:
Indoor unit
• Trouble of
room temp-
erature/
indoor coil
thermistor
3-time flash
Cause:
Indoor unit
• Trouble of
indoor fan
motor
Refer to
10-5. or
"How to
check
mis-wiring/
and serial
signal error
(When
outdoor unit
does not
work)".
Check room
temperature
thermistor
and indoor
coil thermis-
tor.
Refer to 10-6.
"Test point
diagram and
voltage".
Refer to
10-5.
"Check of
indoor fan
motor".
4-time flash
Cause:
Indoor unit
• Trouble of
indoor unit
control
system
Replace the
indoor
electronic
control
P.C. board.
Refer to outdoor unit service manual.
1. Check indoor/
outdoor
connecting wire.
2. Refer to 10-5.
"Check of indoor
electronic control
P.C. board".
Outdoor unit
does not
stop even
if indoor unit
stops.
MUH/MXZ
Unit does not
operate
normal
operation in
COOL or
HEAT mode.
MU
Check of wiring
diagram of
outdoor unit
MUH
Refer to
"Check of
outdoor unit".
Refer to
"Check of
R.V. coil".
2."Test run operation" means the operation within 30 minutes after EMERGENCY OPERATION switch is pressed.
MUH/MUX
Outdoor unit
does not
operate
even in
“Test run
operation”.
Indoor unit
operates.
But indoor
unit does not
blow out
cool air.
MUX-2A28/2A59/3A60/
3A63/2A70/4A73VB
Refer to
"Check of
indoor/outdoor
units' connection
and outdoor
unit".
MUH/MXZ
6-time flash
Cause:
Outdoor unit
• Trouble of
thermistor
in outdoor
unit
MUH/MXZ
7-time flash
Cause:
Outdoor unit
• Trouble of
outdoor
control
system
Refer to
"Check of
outdoor
thermistor"
and others.
Replace the
deicer
P.C. board
and others.
10-time flash
Cause:
Outdoor unit
MXZ
• Outdoor
refrigerant
system
abnormality
Refer to
outdoor
refrigerant
system
related items.
MXZ
5-time flash
Cause:
Outdoor unit
• Outdoor
power
system
abnormality
Refer to
"Check of
inverter/
compressor"
and "Check
of power
supply".
1.<The case of the trouble of the serial signal>
When the power is turned off and turned on again, the indication shows “the trouble of mis-wiring”.
10-2. INSTRUCTION OF TROUBLESHOOTING
OBH529A
Page view 22