10
SUZ-KA50VA2
MFZ Series
Compact console
Console Type Specifications
Type
Model Name
Indoor Unit
Outdoor Unit
Power Supply [V, Phase, Hz]
MFZ-KA25VA
MFZ-KA25VA
SUZ-KA25VA2
0.9 - 2.5 - 3.4
0.19 - 0.58 - 0.94
4.31
3.0
2.8
22 - 27 - 32 - 37
46 (59)
80 - 145
0.9 - 3.4 - 5.1
0.19 - 0.835 - 1.91
4.07
3.0
4.0
22 - 27 - 32 - 37
46 (59)
83 - 152
4.0
6.4
25
600 x 700 x 200
14
550 x 800 x 285
33
10
9.52 / 6.35
20 / 12
-10 ~ 46
-10 ~ 24
MFZ-KA35VA
MFZ-KA35VA
SUZ-KA35VA2
0.9 - 3.5 - 3.9
0.19 - 1.09 - 1.25
3.33
2.0
5.0
23 - 28 - 33 - 38
47 (61)
83 - 152
0.9 - 4.0 - 6.2
0.19 -1.10 - 2.24
3.64
2.5
5.0
25 - 28 - 33 - 38
48 (61)
87 - 158
5.0
9.4
25
600 x 700 x 200
14
550 x 800 x 285
37
10
9.52 / 6.35
20 / 12
-10 ~ 46
-10 ~ 24
MFZ-KA50VA
MFZ-KA50VA
SUZ-KA50VA2
0.9 - 4.8 - 5.4
0.19 - 1.55 - 1.98
3.10
1. 5
7. 0
32 - 35 - 39 - 43
53 (68)
118 - 178
0.9 - 6.0 - 7.9
0.19 - 1.86 - 2.81
3.23
2.0
8.5
32 - 35 - 39 - 44
55 (68)
123 - 197
8.5
16.2
25
600 x 700 x 200
14
850 x 840 x 330
53
10
12.7 / 6.35
30 / 15
-10 ~ 43
-10 ~ 24
Inverter Heat Pump (R410A)
Cooling
Heating
Starting Current
Max. Running Current
Indoor
Outdoor
Ext. Piping
Guaranteed Operating Range
[Outdoor]
*
SH = Super High
Capacity [Min. - Rated - Max.]
Total Input [Min. - Rated - Max.]
Rated EER
Running Current [Rated]
Sound Pressure
Level
†
Air Volume (IN) [Lo - SH]
Capacity [Min. - Rated - Max.]
Total Input [Min. - Rated - Max.]
Rated COP
Running Current [Rated]
Sound Pressure
Level
Air Volume (IN) [Lo - SH*]
Input [Rated]
Dimensions [H x W x D]
Weight
Dimensions [H x W x D]
Weight
Breaker Size
Diameter (Gas / Liquid)
Max. Length / Height
Star Rating
IN [Lo - Med - Hi - SH*]
OUT at 1m (PWL)
Star Rating
IN [Lo - Med - Hi - SH*]
OUT at 1m (PWL)
Cooling
Heating
kW
kW
A
dB(A)
dB(A)
l
/S
kW
kW
A
dB(A)
dB(A)
l
/S
A
A
W
mm
kg
mm
kg
A
mm
m
o
C
o
C
230V, Single, 50Hz , Outdoor unit power supply
†
Indoor sound pressure level generally measured at 1.5 metres. For exact details see Technical Data Manual.
†
MXZ
connection
Failure
Recall
Flare
connection
20m
12m
KA25/35
30m
15m
KA50
VERTICAL
AIRFLOW
Easy
Installation
with Leveling Plate
Auto Restart
Self
Diagnosis
ACO
Weekly
Timer
Optional
Centralized
On/ Off
Optional
M-NET
connection
Optional
Heating at
-15˚C
Optional
i save
Cooling at
46˚C/-10˚C
KA25 / 35
Cooling at
-10˚C
DC
Inverter
PAM
Control
Econo Cool
Compact
Pure
White
24-hour Timer
Catechin
as Standard filter
as Standard filter
Anti-Allergy
Enzyme
AUTO
VANE
HORIZONTAL
Only
22dB
KA25
HORIZONTAL
SWING
INDOOR UNIT
OUTDOOR UNIT
SUZ-KA25/35/VA2
HEAT PUMP
REMOTE
CONTROLLER
OPTIONAL WIRED
CONTROLLERS
10