37
Unit:mm
Refrigerant pipe diameter is different according to indoor unit to be connected. When using extension pipes,refer to the
tables below.
When diameter of refrigerant pipe is different from that of outdoor unit union, use optional Different-diameter pipe.
For further information on Different-diameter pipe,see 16-1.
Outdoor unit union diameter
For
Liquid 6.35(1/4)
Indoor unit A
Gas 12.7(1/2)
Liquid 6.35(1/4)
Indoor unit B
Gas 9.52(3/8)
Liquid 6.35(1/4)
Indoor unit C
Gas 9.52(3/8)
Liquid 6.35(1/4)
Indoor unit D
Gas 9.52(3/8)
Unit : mm (inch)
Piping length each indoor unit (a, b, c, d) 25m
Total piping length (a+b+c+d) 60m
Bending point for each unit 25
Total bending point 60
It does not matter which unit is higher.
a
b
c
d
Outdoor
unit
Indoor
units
15m
10m
15m
Refrigerant piping length (one way, 4 unit total)
Calculation : Xg=20g/mx(Refrigerant piping length(m)-40)
Outdoor unit
precharged
50m
200
40m
0
2,700
60m
400
MXZ-4A71VA
Indoor unit
D
Ball valve with
service port
Ball valve
Power
receiver
LEV A
LEV B
LEV C
LEV D
Oil separator
Compressor
Muffler
4-way valve
LEV E
Unit D gas pipe
temperature thermistor
[9.52
Indoor unit
C
Unit C gas pipe
temperature thermistor
[9.52
[6.35
[6.35
[6.35
[6.35
Indoor unit
B
Unit B gas pipe
temperature thermistor
[9.52
Indoor unit
A
Indoor unit
A
Indoor unit
B
Indoor unit
C
Indoor unit
D
Unit A gas pipe
temperature thermistor
[12.7
[12
[16
[16
[16
Capillary tube
[2.5[0.61000
[9.52
Capillary tube
[4.0[2.8 100
Discharge
temperature
thermistor RT62
Strainer
#100
Strainer
#100
Strainer
#100
Strainer
#100
Strainer
#100
R.V. coil
OFF
ON
Refrigerant flow in cooling
Refrigerant flow in heating
[12
Distributor
HEX-OUT
Outdoor heat
exchanger
temperature
thermistor
RT68
Defrost
thermistor
RT61
Capillary tube
[3.6[2.4500 (8 pcs)
Ambient
temperature
thermistor
RT65
FAN-OUT
Strainer
#100
MAX REFRIGERANT PIPING LENGTH
Indoor unit
Extension pipe diameter
class Pipe diameter
Liquid 6.35(1/4) Liquid 6.35(1/4)
22/25/35
Gas 9.52(3/8) Gas 9.52(3/8)
Liquid 6.35(1/4) Liquid 6.35(1/4)
50
Gas 12.7(1/2) Gas 12.7(1/2)
Liquid 6.35(1/4) Liquid 6.35(1/4)
60
Gas 15.88(5/8) Gas 15.88(5/8)