After the installation and wiring work, be sure to install the provided
terminal cover on the product when you want to activate and operate
the module. Failure to do so results in the risk of electric shock.
Fully mount the antenna cable to the module connector. After
mounting, check for separation. Insufficient contact results in the
risk of erroneous input and output.
Be sure to place the communication cables and power cables
connected to the module in a duct, or secure them with clamps.
Failure to do so results in the risk of cable movement and drift,
module or cable damage caused by careless pulling, and malfunction
caused by insufficient cable contact.
When connecting a cable, first verify the connection interface type
and then connect the cable properly. Connecting a cable to a
wrong interface or mis-wiring a cable results in the risk of
external device malfunction.
Tighten the screws within the specified torque range. If a screw
is too loose, a short circuit or malfunction may result. If a screw
is too tight, screw and/or module damage may occur, resulting
in a short circuit, or malfunction.
When removing a communication cable or power cable connected
to the module, do not pull the cable section. For cables with
connectors, hold the connector of the section connected to the
module during removal. For terminal block cables, loosen the
screws of the terminal block and then remove the cable. Pulling
a cable while it is connected to the module results in the risk of
malfunction and module and cable damage.
Be careful to prevent foreign matter such as dust or wiring chips
from entering the module.
Failure to do so may result in the risk of fire, failure, and malfunction.
EQ-V680D1
EQ-V680D2
EQ-V680D1
EQ-V680D2
Model
Manuals
Item
1
Manual 1
Ferrite core 1
90.5
(16)
(50)
27.4
Unit: mm
90.5
(16)
(50)
27.4
Unit: mm
(Connection example)
+24VDC
Line filter
0V
Ring section
Item
1 unit 2 units
1)
3)
2)
4)
1)
3)
2)
4)
No.
1)
2)
3)
4)
RUN
BSY.
EQ-V680D1/EQ-V680D2
50CM-D180056-C(1404)MEE
SAFETY PRECAUTIONS
(Always read these precautions prior to use.)
Before using this product, please read this manual and the
relevant manuals introduced in this manual carefully and
pay full attention to safety to ensure that the product is
used correctly.
The precautions presented in this manual are concerned
with this product only.
For programmable controller system safety precautions,
refer to the user's manual of the CPU module used.
In this manual, the safety precautions are ranked as
"WARNING" and "CAUTION".
WARNING
CAUTION
Indicates that incorrect handling may
cause hazardous conditions, resulting
in death or severe injury.
Indicates that incorrect handling may
cause hazardous conditions, resulting
in medium or minor injury and/or
property damage.
Note that failure to observe the
CAUTION level
instructions may lead to a serious consequence according
to the circumstances. Always follow the precautions of both
levels because they are important to personal safety.
Please keep this manual in an easy-to-access location for
future reference, and be sure to deliver the manual to the
end user.
[INSTALLATION PRECAUTIONS]
The manuals related to this product include the following.
Feel free to order the manual if needed.
Detailed manuals
Manual Title
RFID Interface Module User's Manual
(Details)
Manual Number
50CM-D180057
Manual Title Manual Number
(1) This product
To make this product compliant with the EMC Directive and
Low Voltage Directive, the following countermeasure is required.
1. OVERVIEW
This user's manual describes the specifications, part names,
installation, wiring and connections with other devices, and
other information related to the EQ-V680D1/EQ-V680D2 RFID
interface module (hereinafter "RFID interface module") used in
combination with the MELSEC-Q series CPU module.
Once you have opened the product package, verify that the
package contains the following.
Quantity
RFID interface module main unit
2. PERFORMANCE SPECIFICATIONS
The following describes the performance specifications of the
RFID interface module. For the general specifications of the
RFID interface module, refer to the user's manual of the CPU
module used.
Specifications
Item
Specifications
Model
Manufactured by
Omron Corporation
Connectable antenna
No. of connectable
antennas
No. of occupied IO points
Data transfer volume
Power supply
Internal power supply
(supplied from inside
the 5VDC programmable
controller)
External power supply
24VDC
(20.4VDC to 26.4VDC)
EQ-V680D1
EQ-V680D2
V680-HA63A
+V680-HS
V680-HA63B
+V680-HS
V680-H01-V2
V680-HA63A
+V680-HS
V680-HA63B
+V680-HS
32 points (IO assignments
: 32 intelligent module points)
2048 bytes, maximum
0.42A
0.25A
0.52A
0.37A
3. MOUNTING AND INSTALLATION
3.1 Handling Precautions
3.2 Installation Environment
Refer to the user's manual of the CPU module used.
3.3 Cable Installation
When installing the antenna cable to the RFID interface
module, be sure that excessive external force is not
applied to the connector connecting area of the module.
4. PART NAMES AND SETTINGS
The following explains the names of each part of the RFID
interface module.
Description
Name
LED display
Test switch
Antenna
connector
Power supply
terminal
Indicates the operating status of the RFID
interface module.
[For display details, refer to Section (1).]
Used to switch between RUN mode and
TEST mode.
A connector for antenna connection.
A terminal for 24VDC power supply
connection.
(1) LED List
LED
Name
NOM.
ERR.
EXT.PW
Display Details
Indicates normal operation.
Indicates the operating
status of each channel.
Indicates the communication
completion status of each
channel.
Indicates whether or not an
error exists on each channel.
Indicates the status of the
power supply to the antenna.
: On
: OFF
Normal
Running
Normal
completion
Error
Normal
Abnormal
Waiting
Waiting or
abnormal
completion
Normal
Abnormal
5.2 Wiring the Power Supply Terminal
The following shows a wiring diagram of the power supply
terminal.
(1) A circuit (class 2 circuit) having a class 2 power supply
module in accordance with
UL1310 or a class 2 transformer in accordance with UL1585
as a power supply, and a maximum voltage of 30Vrms
(42.4 peak) or less.
Recommended DC power supply
Manufactured by Omron Corporation
(small-sized DIN rail installation type)
Model Output Capacity Input Voltage
S8VS-03024 24VDC, 1.3A
100 to 240VAC
While simply corrective action within the RFID interface
module is sufficient to counter the noise superimposed on
the power line, the noise to the ground can be significantly
reduced by supplying power via a line filter.
5.3 Inserting and Removing the Antenna and Cable
When inserting or removing an antenna or cable, follow the
procedures below.
(1) Insertion Method
[1] Hold the section of the connector that secures the cable
and insert the connector with the white dot facing upward.
[2] Push the connector straight in until the connector locks.
CAUTION
Do not insert the connector with the power
supply ON. Doing so results in the risk of failure.
The connector will not lock if you push the ring
section. Be sure to hold and push the section
that secures the cable.
The connector cannot be removed by holding
and pulling the section that secures the cable.
Pulling that section results in the risk of breakage
and damage. Do not pull the cable with force.
Do not remove the connector with the power
ON. Doing so results in the risk of failure.
Section that
secures the cable
Ring section
Section that
secures the cable
CAUTION
(2) Removal Method
[1] Hold onto the ring section and pull straight back.
6. EXTERNAL DIMENSIONS
(1) EQ-V680D1
98
R40 or more
R40 or more
98
(2) EQ-V680D2
Product Warranty Details
Please confirm the following product warranty details prior to
product use.
Gratis Warranty Terms and Gratis Warranty Range
If any fault or defect (hereinafter referred to as "Failure")
attributable to Mitsubishi Electric Engineering Company Limited
(hereinafter referred to as "MEE") should occur within the gratis
warranty period, MEE shall repair the product free of charge via
the distributor from whom you made your purchase.
Gratis Warranty Period
The gratis warranty period of this product shall be one (1)
year from the date of purchase or delivery to the designated
place. Note that after manufacture and shipment from MEE,
the maximum distribution period shall be six (6) months, and
the gratis warranty period after manufacturing shall be limited
to eighteen (18) months.
In addition, the gratis warranty period for repaired products
shall not exceed the gratis warranty period established prior
to repair.
Gratis Warranty Range
The gratis warranty range shall be limited to normal use based
on the usage conditions, methods and environment, etc.,
defined by the terms and precautions, etc., given in the
instruction manual, user's manual and caution labels on the
product.
Warranty Period after Discontinuation of Production
(1) MEE shall offer product repair services (fee applied) for
seven (7) years after production of the product has been
discontinued. Discontinuation of production shall be reported
via distributors.
(2) Product supply (including spare parts) is not possible after
production has been discontinued.
Exclusion of Opportunity Loss and Secondary Loss
from Warranty Liability
Regardless of the gratis warranty period, MEE shall not be
liable for compensation for damages arising from causes not
attributable to MEE, opportunity losses or lost profits incurred
by the user due to Failures of MEE products, damages or
secondary damages arising from special circumstances, whether
foreseen or unforeseen by MEE, compensation for accidents,
compensation for damages to products other than MEE products,
or compensation for other work carried out by the user.
Changes in Product Specifications
The specifications given in the catalogs, manuals and technical
documents are subject to change without notice.
This document is a new publication, effective April 2014.
Specifications are subject to change without notice.
The standard price does not include consumption tax.
Please note that consumption tax will be added at the time of
purchase.
Developed April 2014
50CM-D180056-C
[DESIGN PRECAUTIONS]
CAUTION
Provide a safety circuit outside the programmable
controller to ensure that the overall system operates
safely in the event of an error in the external power
supply or failure of the programmable controller itself.
Failure to do so results in the risk of erroneous output
and malfunction and, in turn, module failure.
CAUTION
Configure the circuitry so that the external power supply is
activated after the power supply of the programmable controller
itself. Activating the external power supply first results in the risk
of erroneous output and malfunction and, in turn, module failure.
When installing the RFID interface module and amplifier/antenna
cables, do not bundle the cables with or install the cables close
to the main circuit, power lines, or the like. Be sure to separate
the cables and lines by about 100mm or more. Failure to do so
will cause noise and, in turn, malfunction.
When storing the product, be sure to observe the defined storage
ambient temperature and humidity. Failure to do so will lead to
module malfunction and failure.
Look the control panel so that only those who trained with
enough knowledge about the electric facilities can be opened.
Install the emergency stop switch outside the control panel so
that workers can operate it easily.
CAUTION
Use the programmable controller in an environment that reflects
the general specifications stated in the user's manual of the CPU
module used. Using the programmable controller in an environment
out of the general specification range results in the risk of electric
shock, fire, malfunction, and product damage or deterioration.
During installation, fully insert the tabs used to secure the module
into the holes of the base unit while pressing down the module
mounting lever located at the bottom of the module. An incorrectly
mounted module results in the risk of malfunction, failure, and
dropping. When used in an environment of high oscillation, secure
the module with screws.
Tighten the screws within the specified torque range. If a screw
is too loose, a dropped module, short circuit, or malfunction may
result. If a screw is too tight, screw and/or module damage may
occur, resulting in a dropped module, short circuit, or malfunction.
CAUTION
Be sure to shut off all phases of the external power supply used
by the system before module installation or removal.
Failure to do so results in the risk of product damage.
Do not directly touch a powered section or electronic component
of the module. Doing so results in the risk of module malfunction
and failure.
[WIRING PRECAUTIONS]
CAUTION
RFID Interface Module
EQ-V680D1
EQ-V680D2
User's Manual
(Hardware)
Model
HEAD OFFICE:Hulic KUDAN BLDG.1-13-5, KUDANKITA CHIYODA-KU, TOKYO 102-0073, JAPAN
NAGOYA ENGINEERING OFFICE:139 SHIMOYASHIKICHO-SHIMOYASHIKI, KASUGAI, AICHI 486-0906, JAPAN
CAUTION
A protective film is attached to the top of the module to prevent
foreign matter, such as wire chips, from entering the module
during wiring.
Do not remove the film during wiring.
Remove it for heat dissipation before system operation.
Do not connect the power supply in reverse. Doing so results
in risk of failure.
Use the module after confirming that the external input DC power
supply is within the rated power supply voltage.
Failure to do so results in the risk of failure and malfunction.
Do not bundle the control or communication cables with or install
the cables close to the main circuit, power lines, or the like. Be
sure to separate the cables and lines by about 100mm or more.
QCPU User's Manual
(Hardware Design, Maintenance and Inspection)
Manufactured by Mitsubishi Electric Corporation
Mitsubishi general-purpose programmable controller
MELSEC-Q series manual
EQ-V680D1 EQ-V680D2
5. CONNECTING THE MODULE
5.1 Wiring Precautions
Connect the 24VDC power supply to the power supply of (1) below.
SH-080483ENG
To suppress radiation noise, use a ferrite core. The method
of use is as follows:
Bring together the power supply cable of the programmable
controller power supply module and the grounding wire and
route them through the ferrite core. The target position of the
ferrite core is within 10cm from the power supply module.
Authorized representative in Europe
Authorized representative in Europe is shown below.
Name :Mitsubishi Electric Europe B.V.
Address :Gothaer strasse 8, 40880 Ratingen, Germany
+24VDC
0V
FG
LG
INPUT
100-240VAC
Programmable controller
Power
supply
CPU
module
Ferrite core
(within 10cm from the power supply contact)
Grounding
wire
Power supply
cable
EMC AND LOW VOLTAGE DIRECTIVES
Compliance to the EMC Directive, which is one of the EU Directives,
has been a legal obligation for the products sold in European countries
since 1996 as well as the Low Voltage Directive since 1997.
Manufacturers who recognize their products are compliant to the
EMC and Low Voltage Directives are required to declare that
print a "CE mark" on their products.
Outer dimensions 98(H) 27.4(W) 90.5(D)[mm]
Item
Specifications
Power supply
Weight
0.2kg
0.2kg
External power supply
connection terminal
2-point terminal block
Compatible crimp
contact lugs
1.25-3, R1.25-3
Connector connecting area
RFID interface module
Antenna cable
Installation bending radius:
40mm or greater
Secure in such a manner that external force is
not applied to the connector connecting area.
*2
*1
*1: "The Power Supply shall comply with the requirements in
the standard for an isolated secondary limited voltage, limited
current (LVLC) circuit, defined by UL508." or equivalent.
*2: For external power supply details, refer to Section 5.2.
Module screw (M3 screw)
0.52 to 0.57N m (4.6 to 5.1lbf in)
0.36 to 0.48N m (3.2 to 4.3lbf in)
*1
(1) The RFID interface module case is made of plastic. Do
not drop the case or expose the case to strong impact.
(2) Before touching the module, be sure to touch grounded
metal or the like to release the static electricity from your
body.
(3) Tighten the module screws, etc., within the ranges
indicated below. Insufficient tightening results in the risk
of a short circuit, failure, and malfunction.
Screw Location
Tightening Torque Range
Power supply terminal block
screw (M3 screws)
*1: The module can be simply secured to the base unit by the
hooks located on top of the module. Note, however, that we
recommend securing the module using screws in locations
of high oscillation.
Wiring recommendations
Wire standard
Heat Resistant PVC Insulated Wire
JIS C 3316 HKIV,JIS C 3317 HIV,
UL 758 Style No.1007or1015
Temperature rating
Minimum 75
Voltage rating
300V to 600V
Conductors wire
size
AWG18(0.75mm
2
, 0.9mm
2
)
Conductors metal
Stranded copper
CAUTION
ATTENTION
Do not wire the cables near or bundle the cables with
main circuit cables, or power lines.
Doing so causes noise and surge impact, resulting in
the risk of malfunction. Be sure to separate the cables
and lines by about 100mm or more.
When using a group of equipment, such as inverters,
servo motors, and the like, be sure to execute class D
grounding (type 3 grounding). Failure to do so results in
the risk of magnetic field interference and malfunction.
Do not invert the EXT.PW polarity of an external power
supply during connection.
The RFID interface module will not operate.
Do not connect directly to line voltage. Line voltage
must be supplied by a suitable,approved isolating
transformer or power supply having short circuit capacity
not exceeding 100VA maximum or equivalent.
Ne pas se connecter directement à la tension de ligne.
La tension de ligne doit être fournie par un transformateur
d'isolement approprié et approuvé ou par un bloc
d'alimentation ayant une capacité de court-circuit ne
dépassant pas 100 VA au maximum ou équivalent.
Operating temperature
Operating humidity
5 to 95%RH
Pollution degree
2
Operating ambience
No corrosive gases
Operating altitude
Overvoltage category
Enclosure
0 to 55
(Maximum surrounding
air temperature 55)
0 to 2000m
open type equipment
(Must be mounted within
an enclosure.)
Page view 0
1

Summary of Contents

Page 1 - (Hardware)

After the installation and wiring work, be sure to install the provided terminal cover on the product when you want to activate and operate the module

Comments to this Manuals