Mitsubishi 20-MYA Specifications Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
ELECTRICAL DATA
VOLT
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
COMPRESSOR INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
I/D FAN External static pressure
INPUT
RUN CURRENT
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
COMPRESSOR INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
I/D FAN External static pressure
INPUT
RUN CURRENT
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
COMPRESSOR INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
I/D FAN External static pressure
INPUT
RUN CURRENT
415V
400V
380V
kW
A
%
A
kW
A
kW
A
Pa
kW
A
kW
A
%
A
kW
A
kW
A
Pa
kW
A
kW
A
%
A
kW
A
kW
A
Pa
kW
A
7.9/8.3
13.3/14.0
82%
77.8
6.6
10.4
0.5
1.5
62/100
0.8/1.2
1.4/2.1
7.9/8.3
13.8/14.5
82%
80.8
6.6
10.7
0.5
1.6
50/100
0.8/1.2
1.5/2.2
7.9/8.3
14.5/15.3
82%
85.0
6.6
11.4
0.5
1.6
50/100
0.8/1.2
1.5/2.3
6.6/7.0
11.1/11.8
83%
77.8
5.3
8.2
0.5
1.5
62/100
0.8/1.2
1.4/2.1
6.6/7.0
11.6/12.3
83%
80.8
5.3
8.5
0.5
1.6
50/100
0.8/1.2
1.5/2.2
6.6/7.0
12.1/12.9
83%
85.0
5.3
9.0
0.5
1.6
50/100
0.8/1.2
1.5/2.3
10.9/11.4
17.8/18.5
86%
76.3
9.0
14.5
0.5
1.3
62/100
1.4/1.9
2.0/2.7
10.9/11.4
18.5/19.2
86%
79.1
9.0
15.1
0.5
1.3
62/100
1.4/1.9
2.1/2.8
10.9/11.4
19.4/20.2
86%
83.3
9.0
15.9
0.5
1.4
62/100
1.4/1.9
2.1/2.9
9.4/9.9
15.3/16.0
86%
76.3
7.5
12.0
0.5
1.3
62/100
1.4/1.9
2.0/2.7
9.4/9.9
15.8/16.5
86%
79.1
7.5
12.4
0.5
1.3
62/100
1.4/1.9
2.1/2.8
9.4/9.9
16.6/17.4
86%
83.3
7.5
13.1
0.5
1.4
62/100
1.4/1.9
2.1/2.9
ITEM
PRHG-8MYA PRHG-10MYA
Cooling Heating HeatingCooling
VOLT
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
COMPRESSOR INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
I/D FAN External static pressure
INPUT
RUN CURRENT
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
COMPRESSOR INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
I/D FAN External static pressure
INPUT
RUN CURRENT
TOTAL INPUT
TOTAL RUN CURRENT
POWER FACTOR
START CURRENT
COMPRESSOR INPUT
RUN CURRENT
O/D FAN INPUT
RUN CURRENT
I/D FAN External static pressure
INPUT
RUN CURRENT
415V
400V
380V
kW
A
%
A
kW
A
kW
A
Pa
kW
A
kW
A
%
A
kW
A
kW
A
Pa
kW
A
kW
A
%
A
kW
A
kW
A
Pa
kW
A
15.7/16.4
26.3/27.5
83%
104.5
13.2
20.9
1.0
2.8
100/200
1.5/2.2
2.6/3.8
15.7/16.4
27.3/28.5
83%
108.4
13.2
21.7
1.0
2.9
100/200
1.5/2.2
2.7/3.9
15.7/16.4
28.7/30.0
83%
114.2
13.2
22.7
1.0
3.1
100/200
1.5/2.2
2.9/4.2
14.0/14.7
23.5/24.7
83%
101.7
11.5
18.1
1.0
2.8
100/200
1.5/2.2
2.6/3.8
14.0/14.7
24.4/25.6
83%
105.5
11.5
18.8
1.0
2.9
100/200
1.5/2.2
2.7/3.9
14.0/14.7
25.7/27.0
83%
111.1
11.5
19.7
1.0
3.1
100/200
1.5/2.2
2.9/4.2
21.0/22.1
34.2/35.7
86%
110.6
17.5
28.2
1.0
2.6
100/200
2.5/3.6
3.4/4.9
21.0/22.1
35.4/37.0
86%
114.7
17.5
29.2
1.0
2.7
100/200
2.5/3.6
3.5/5.1
21.0/22.1
37.4/39.0
86%
120.7
17.5
30.8
1.0
2.8
100/200
2.5/3.6
3.8/5.4
18.2/19.3
29.7/31.2
86%
106.1
14.7
23.7
1.0
2.6
100/200
2.5/3.6
3.4/4.9
18.2/19.3
30.8/32.4
86%
110.1
14.7
24.6
1.0
2.7
100/200
2.5/3.6
3.5/5.1
18.2/19.3
32.5/34.1
86%
115.8
14.7
25.9
1.0
2.8
100/200
2.5/3.6
3.8/5.4
ITEM
PRHG-15MYA PRHG-20MYA
Cooling Heating HeatingCooling
-6-
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 61 62