18
Model
Specifications
2.8 4.5
9600
2400
3.2
10900
2800
12/11/10
424/388/353
41/38/36
3.6
12300
3100
4
13700
3400
14/12/10
494/424/353
43/40/38
4.5
15400
3900
5
17100
4300
14/12/10
494/424/353
43/40/38
15400
3900
5
17100
4300
14/12/10
494/424/353
7.1
24200
6100
8
27300
6900
18/15/12
636/530/424
43/41/40
184x1000x650+240
5.6
19100
4800
6.3
21500
5400
14/12/10
494/424/353
43/40/38
7.1
24200
6100
8
27300
6900
18/15/12
636/530/424
44/40/38
239x1470x650+240
27 34 40
p9.52
p15.88 p19.05
VP20 VP20
1p220/240V,50Hz 1p220/240V,50Hz
p6.35
p12.7
22
p6.35
p12.7
32
p9.52
p15.88
40
630x1196x225
630x1481x225
Cooling capacity kW
BTu/h
kcal/h
Heating capacity
Air Flow Rate
(H/M/L)
Sound Level(H/M/L)
Dimension(
HxWxD)
Machine Weight
Power Source
kW
BTu/h
kcal/h
cfm
dB(A)
mm
kg
FDEJ36HKXE2 FDEJ45HKXE2 FDEJ56HKXE2
FDE FDFL FDFU
FDEJ71HKXE2 FDEJ112HKXE2
FDEJ140HKXE2
FDFLJ28HKXE2
FDFLJ45HKXE2 FDFLJ71HKXE2
11.2
38200
9600
12.5
42700
10800
28/25/22
988/883/777
49/46/42
239x1260x650+240
184x1260x650+240
14
47800
12000
16
54600
13800
34/30/26
1200/1059/918
50/47/42
m/min
3
Liquid(Flare)mm
Gas(Flare)mm
Drain Piping
Connection
Refrigerant
Lines
VP20
1p220/240V,50Hz
2.8
9600
2400
3.2
10900
2800
12/11/10
424/388/353
41/38/36
p6.35
p12.7
FDFUJ28HKXE2
4.5
15400
3900
5
17100
4300
14/12/10
494/424/353
25
630x1077x225
FDFUJ45HKXE2
5.6
6.3
43/41/40
p9.52
p15.88
FDFUJ56HKXE2
7.1
24200
6100
8
27300
6900
18/15/12
636/530/424
32
630x1362x225
FDFUJ71HKXE2
FDE Ceiling Suspended Type
OEasy retro-fit application. Low operating noise level and
comfort combined with eye appealing style.
O38dB(A)for FDE56model. This makes for the lowest noise
level in the industry.
OThe unit thickness is thin 184mm.
OBy the use of aero-wing louvers, downward air supply angle of
up to 75degrees is possible. The angle can be fixed by the use of
the remote controller.
OAt the time of heating operation start or at the time of defrost
(when the defrost thermostat is at off), the louvers air supply
angle is automatically set to horizontal derection.
Floor Type Lowboy FDFL/FDFU
OThe 630mm Lowboy type leaves ample space for windows.
OThe embedded type is suitable for blending in with the interior
decoration, and is easily housed in the perimeter space.
OThe pipes can be connected either at the below or back of the unit.
OThe air blow angle can be adjusted from vertically
above to 60 degrees forward.
FDE
Ceiling Suspended Type
FDFL/FDFU
Floor Standing Type
Page view 0
1

Summary of Contents

Page 1 - FDFL/FDFU

18ModelSpecifications2.8 4.5960024003.210900280012/11/10424/388/35341/38/363.6123003100413700340014/12/10494/424/35343/40/384.5154003900517100430014/1

Comments to this Manuals