Mitsubishi MSZ-GA50 VA Service Manual

Browse online or download Service Manual for Split-system air conditioners Mitsubishi MSZ-GA50 VA. Mitsubishi MSZ-GA50 VA Service manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 56
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ····································3
2. PART NAMES AND FUNCTIONS······················6
3. SPECIFICATION·················································6
4. NOISE CRITERIA CURVES·······························7
5. OUTLINES AND DIMENSIONS ·························8
6. WIRING DIAGRAM ············································9
7. REFRIGERANT SYSTEM DIAGRAM··············12
8. PERFORMANCE CURVES······························15
9. ACTUATOR CONTROL····································26
10. SERVICE FUNCTIONS·····································27
11. TROUBLESHOOTING······································27
12. DISASSEMBLY INSTRUCTIONS·····················46
13. PARTS LIST······················································50
14. RoHS PARTS LIST···········································54
Wireless type
Models
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
MUZ-GA50VA -
MUZ-GA60VA -
MUZ-GA60VA -
MUZ-GA60VA -
MUZ-GA71VA -
MUZ-GA71VA -
E2
E1
E3
E2
E1
E1
HFC
utilized
R410A
NOTE:
• RoHS compliant products have <G> mark on the spec name plate.
For servicing of RoHS compliant products, refer to the RoHS Parts List.
• Contents of SERVICE FUNCTIONS(10) have been removed.
No. OB389
REVISED EDITION-F
Indoor unit service manual
MSZ-GAVA Series (OB388)
Please void OB389 REVISED EDITION-E.
OUTDOOR UNIT
Revision F:
• MUZ-GA60VA- has been added.
E3
OB389F--1qxp 07.9.3 5:06 PM Page 1
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - OUTDOOR UNIT

SERVICE MANUALCONTENTS1. TECHNICAL CHANGES ····································32. PART NAMES AND FUNCTIONS······················63. SPECIFICATION····

Page 2

10MUZ-GA60VA -E3OB389F--1qxp 07.9.3 5:07 PM Page 10

Page 3 - TECHNICAL CHANGES

11MUZ-GA71VABLKCN90212CN90312TAB4X64 3R64A R64BRED2314LYLWYLWRED230V~12-24VCN912CN663WHTBLUNOISEFILTERP.C.BOARDBRNTO INDOORUNITCONNECTINGREDS3RT6521CN

Page 4

12REFRIGERANT SYSTEM DIAGRAM7MUZ-GA50VAMUZ-GA60VA -E1Unit:mmOutdoorheatexchangerFlared connectionDefrostthermistorRT61DischargetemperaturethermistorRT

Page 5 - 2.Refrigerant piping

13MUZ-GA71VAUnit:mmOutdoorheatexchangerFlared connectionDefrostthermistorRT61DischargetemperaturethermistorRT62Flared connectionStop valveStop valve(w

Page 6 - SPECIFICATION

14Refrigerant PipingMax. length AMax. Heightdifference BIndoorunitOutdoor unitMAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCEMode

Page 7 - NOISE CRITERIA CURVES

15PERFORMANCE CURVES8The standard specifications apply only to the operation of the air conditioner under normal conditions. Since operating condi-tio

Page 8 - OUTLINES AND DIMENSIONS

16MUZ-GA71VACapacity correction factorsInput correction factorsInput correction factorsCapacity correction factorsCorrection of Cooling capacityThe op

Page 9 - WIRING DIAGRAM

17NOTE : The unit of pressure has been changed to MPa on the international system of units (SI unit system).The conversion factor is: 1(MPa [Gauge]) =

Page 10 - MUZ-GA60VA

18Outdoor unit current (A)Outdoor unit current (A)Ambient temperature(˚C)Ambient temperature(˚C)Outdoor unit current (A)Ambient temperature(˚C)MUZ-GA7

Page 11

19MSZ-GA50VA : MUZ-GA50VAINDOOR INDOORCAPACITY:5.0(kW)INPUT:1460(W)SHF:0.6521OUTDOOR DB(:)25 27 30WB(:)Q SHC SHF Q SHC SHF Q SHC SHF Q SHC SHFINPUT

Page 12 - REFRIGERANT SYSTEM DIAGRAM

Revision A :• RoHS PARTS LIST has been added.• Failure mode recall function(11-2.) has been changed.• Check of HPS(11-6.H) has been corrected.Revision

Page 13

20INDOOR INDOORCAPACITY:5.0(kW)INPUT:1460(W)SHF:0.6535OUTDOOR DB(:)40 43 46WB(:)Q SHC SHF Q SHC SHF Q SHC SHF Q SHC SHFINPUT INPUT INPUT INPUTDB(:)

Page 14

21PERFORMANCE DATA COOL operation at Rated frequencyNOTE Q : Total capacity (kW) SHF : Sensible heat factor DB : Dry-bulb temperatureSHC : Sensible he

Page 15 - PERFORMANCE CURVES8

22INDOOR INDOORCAPACITY:6.0(kW)INPUT:1930(W)SHF:0.6435OUTDOOR DB(:)40 43 46WB(:)Q SHC SHF Q SHC SHF Q SHC SHF Q SHC SHFINPUT INPUT INPUT INPUTDB(:)

Page 16

23INDOOR INDOORCAPACITY:7.1(kW)INPUT:2420(W)SHF:0.6321OUTDOOR DB(:)25 27 30WB(:)Q SHC SHF Q SHC SHF Q SHC SHF Q SHC SHFINPUT INPUT INPUT INPUTDB(:)

Page 17

24INDOOR INDOORCAPACITY:7.1(kW)INPUT:2420(W)SHF:0.6335OUTDOOR DB(:)40 43 46WB(:)Q SHC SHF Q SHC SHF Q SHC SHF Q SHC SHFINPUT INPUT INPUT INPUTDB(:)

Page 18

25PERFORMANCE DATA HEAT operation at Rated frequencyNOTE Q : Total capacity (kW) INPUT : Total power input (W) DB : Dry-bulb temperature WB : We

Page 19 - MSZ-GA50VA : MUZ-GA50VA

269ACTUATOR CONTROLMUZ-GA50VAMUZ-GA60VAMUZ-GA71VARelation between main sensor and actuator.9-3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR9-2. R.V. COI

Page 20

27SERVICE FUNCTIONS10TROUBLESHOOTING113. Troubleshooting procedure1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on an

Page 21 - MSZ-GA60VA : MUZ-GA60VA

28Outline of the functionThis air conditioner can memorize the abnormal condition which has occurred once.Even though LED indication listed on the tro

Page 22

292. Flow chart of the detailed outdoor unit failure mode recall functionOperational procedureNOTE1. Make sure to release the failure mode recall func

Page 23 - MSZ-GA71VA : MUZ-GA71VA

31TECHNICAL CHANGESRefrigerationoilRefrigerantNew refrigerantR410AHFC-32: HFC-125 (50%:50%)Pseudo-azeotropic refrigerantNot includedA1/A172.6-51.41.55

Page 24

303. Outdoor failure mode tableOFF None (Normal)2-time flash3-time flash4-time flash5-time flash6-time flash7-time flash8-time flashLighting LightingL

Page 25

3111-time flash• Check the connecting wire between outdoor electronic control P.C. board and power board.• Replace the power board.• Check t

Page 26 - ACTUATOR CONTROL

3211-3. INSTRUCTION OF TROUBLESHOOTINGStartIndoor unit operates.Outdoor unit doesn't operate.Indoor unit doesn't receive the signal from re

Page 27 - SERVICE FUNCTIONS

3311-4. TROUBLESHOOTING CHECK TABLE LED1(Red) LED2(Yellow)Lightning Twice Outdoor power system• Check the connection of the compressor connecting wir

Page 28

34Primary current protectionSecondary current protectionHigh-pressure protectionDefrosting in cooling3 timesLightingDischarge temperatureprotection• C

Page 29 - Operational procedure

35MUZ-GA50VAMUZ-GA60VAMUZ-GA71VA11-5. TROUBLE CRITERION OF MAIN PARTSPart name FigureCheck method and criterionDefrost thermistor(RT61)Ambient tempera

Page 30

36AACheck of power supplyOutdoor unit does not operate. 11-6. TROUBLESHOOTING FLOWTurn ON power supply.NoYesYesNoNoYesNoYesYesNoReplace the power boar

Page 31

37How to check mis-wiring and serial signal error (when outdoor unit does not work)B• When unit cannot operate neither by the remote controller nor by

Page 32 - INDICATOR lamp cannot

38CCCheck of R.V. coilNoYesNoYesNoYesNoYesNoYes1. Disconnect the lead wire leading to the compressor.2. 3 minutes after turning ON the power supply, s

Page 33 - Lighting

39When OPERATION INDICATOR lamp flashes 5-time.• When heating, room does not get warm.• When cooling, room does not get cool.DDCheck of LEVNoYesNoYesT

Page 34

4-30 -20 -10 0 10 203040 50 60-0.50.00.51.01.52.02.53.03.54.0(MPa [Gauge])R410AR22Conversion chart of refrigerant temperature and pressureSaturated li

Page 35

40GGCheck of outdoor fan motor• Fan motor does not operate or stops operating shortly after starting the operation.FFCheck of outdoor thermistors• Whe

Page 36 - Turn ON power supply

41HHCheck of HPS• When the operation frequency does not go up from lowest frequency.MUZ-GA60VA-MUZ-GA71VAE3Infinity0"NoYes1. Disconnect the conne

Page 37 - Outdoor unit doesn’t operate

42Electromagnetic noise enters into TV sets or radiosIReplace or repair the antenna.Replace or repair the coaxial cable.NoNoNoYesYesNoNoYesYesYesIs th

Page 38 - Check of R.V. coil

4311-7. TEST POINT DIAGRAM AND VOLTAGE1. Outdoor electronic control P.C. boardMUZ-GA50VA MUZ-GA60VA MUZ-GA71VALED 1LED 2CN801325V DC~370V DCInput((CN9

Page 39 - Check of LEV

44{CN912R.V. coil 230V AC230V ACInput230V ACOutput{{CN901To electroniccontrol P.C. boardMUZ-GA50VAMUZ-GA60VAMUZ-GA71VAF64 FUSE250V 2AF911 FUSE250V 1A2

Page 40 - Check of outdoor thermistors

45MUZ-GA50VA MUZ-GA60VA MUZ-GA71VA3. Outdoor power board325-370V DCOutput(Red)(White)Connect to the compressorVoltage among phases: 5V to180VConnect t

Page 41 - Check of HPS

4612DISASSEMBLY INSTRUCTIONS(1) Slide the sleeve and check if there is a locking lever or not.(2) The terminal with this connector has the lock

Page 42

47OPERATING PROCEDUREPHOTOS2. Removing the inverter assembly, inverter P.C. boardand power board (1) Remove the top panel, cabinet and service panel.(

Page 43 - Temperature (;)

485. Removing outdoor fan motor(1) Remove the top panel, cabinet and service panel. (Refer to 1.)(2) Remove the back panel. (Refer to 1.)(3) Disconnec

Page 44 - MUZ-GA71VA

49OPERATING PROCEDUREPHOTOSPhoto 8Welded parts of 4-way valve6. Removing the compressor and 4-way valve(1) Remove the top panel, cabinet and service p

Page 45 - 3. Outdoor power board

5Electronic scale for refrigerant chargingOutdoor unitRefrigerant gas cylinderoperating valveRefrigerant gas cylinderfor R410A with siphonRefrigerant

Page 46 - DISASSEMBLY INSTRUCTIONS

50419911310 122567816142022232425293031313PARTS LIST (non-RoHS compliant)MUZ-GA50VA MUZ-GA60VA MUZ-GA71VA13-1. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRIC

Page 47 - OPERATING PROCEDURE

51MUZ-GA50VA MUZ-GA60VA MUZ-GA71VA13-1. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTSSymbolin WiringDiagramQ'ty/unitRemark

Page 48

52MUZ-GA50VAMUZ-GA60VAMUZ-GA71VA13-2. ACCESSORYSymbolin WiringDiagramQ'ty/unitRemarksPart No.No.Part NameMUZ-GA50 VA -E1MUZ-GA60 VA -E1MUZ-GA71

Page 49

53OB389F--2qxp 07.9.3 5:09 PM Page 53

Page 50 - FUNCTIONAL PARTS

54419911310 122567816142022232425293031314RoHS PARTS LIST (RoHS compliant)MUZ-GA50VA MUZ-GA60VA MUZ-GA71VA14-1. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRI

Page 51

55MUZ-GA50VA MUZ-GA60VA MUZ-GA71VA14-1. OUTDOOR UNIT STRUCTURAL PARTS, ELECTRICAL PARTS AND FUNCTIONAL PARTSSymbolin WiringDiagramQ'ty/unitRemark

Page 52 - 13-2. ACCESSORY

MUZ-GA50VAMUZ-GA60VAMUZ-GA71VA14-2. ACCESSORYSymbolin WiringDiagramQ'ty/unitRemarksPart No.No.RoHSPart NameMUZ-GA50 VA -E1MUZ-GA60 VA -MUZ-GA71

Page 53

6PART NAMES AND FUNCTIONS2Air inletPipingAir outlet(back and side)Drain hoseDrain outletACCESSORIES12Drain socketDrain cap [33 12E1E2E3Single phase230

Page 54

7NOISE CRITERIA CURVES490807060504030201063 125 250 500 1000 2000 4000 8000NC-60NC-50NC-40NC-30NC-20NC-70BAND CENTER FREQUENCIES, HzAPPROXIMATETHRESHO

Page 55

85OUTLINES AND DIMENSIONSUnit: mmMUZ-GA50VAMUZ-GA60VAMUZ-GA71VA30-35-155901984051529966345133036085043050080121840Open as a rule500 mm or more ifthe f

Page 56 - 14-2. ACCESSORY

9WIRING DIAGRAM6MUZ-GA50VAMUZ-GA60VA -MUZ-GA60VA -E2E1R64BYLW230V~12-24VCN912CN663WHTBLUNOISEFILTERP.C.BOARDBRNTO INDOORUNITCONNECTINGREDS3RT6521CN611