Thank you for purchasing the GOT1000 Series.
MODEL GT15-QBUS/GT15-QBUS2/
GT15-ABUS/GT15-ABUS2
BUS CONNECTION UNIT
Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.
MODEL GT15-BUS-U
MODEL
CODE
1D7M39
IB(NA)-0800323-F(0810)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly. The precautions given in this
manual are concerned with this product. In this manual, the safety
precautions are ranked as "DANGER" and "CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances. Always follow the precautions of
both levels because they are important to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
z Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100 mm
(3.94 inch) otherwise malfunctions may occur due to noise.
DANGER
CAUTION
CAUTION
[INSTALLATION PRECAUTIONS]
[WIRING PRECAUTIONS]
[STARTUP AND MAINTENANCE PRECAUTIONS]
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
z Before mounting or dismounting this unit to or from the GOT,
always shut off GOT power externally in all phases.
Not doing so can cause a unit failure or malfunction.
z Use this unit in the environment given in the general
specifications of GT16 User’s Manual or GT15 User's Manual.
Not doing so can cause an electric shock, fire, malfunction or
product damage or deterioration.
z When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range. Undertightening can cause a drop,
failure or malfunction. Overtightening can cause a drop, failure
or malfunction due to screw or unit damage.
z Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all
phases. Not doing so can cause a malfunction.
z Insert and fit the bus connection cable into the connector of the
unit to be connected until it "clicks". After fitting, check for lift
which can cause a malfunction due to a connection fault.
z Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.
z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this
unit directly. Doing so can cause a unit malfunction or failure.
z Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.Not doing so can cause unit or cable
damage due to dangling, moved or accidentally pulled cables or
can cause a malfunction due to a cable contact fault.
z Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
z Dispose of this product as industrial waste.
z Make sure to transport the GOT main unit and/or relevant unit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
GT16 User’s Manual or GT15 User's Manual, as they are
precision devices. Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
DANGER
CAUTION
DANGER
CAUTION
DANGER
CAUTION
CAUTION
CAUTION
Manuals
The following shows manuals relevant to this product.
For relevant manuals, refer to the PDF manuals stored in the GT
Designer2 CD-ROM.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Compliance with the EMC and Low Voltage
Directives
When incorporating the Mitsubishi GOT into other machinery or
equipment and keeping compliance with the EMC and low voltage
directives, refer to "EMC AND LOW VOLTAGE DIRECTIVE" of
GT15 User's Manual.
The CE logo is printed on the rating plate of the GOT, indicating
compliance with the EMC and low voltage directives.
Packing List
The following items are included.
1. Overview
This User's Manual describes the GT15 bus connection unit
(hereafter abbreviated to the bus connection unit).
Use the bus connection unit for making bus connection of the
GOT. Refer to GT16 User’s Manual or GT15 User's Manual for
the applicable GOT.
2. Specifications
The performance specifications of the bus connection unit are
indicated below.
The general specifications of the bus connection unit are the
same as those of the GOT.
Refer to GT16 User’s Manual or GT15 User's Manual for the
general specifications of the GOT.
Detailed Manual
Manual name
Manual Number
(Model code)
GT16 User's Manual
(Sold separately)
SH-080778ENG
(1D7M88)
GT15 User's Manual
(Sold separately)
SH-080528ENG
(1D7M23)
GOT1000 Series Connection Manual
(Sold separately)
SH-080532ENG
(1D7M26)
Relevant Manuals
Model Product Quantity
GT15-QBUS,
GT15-ABUS
Bus connection unit 1
Mounting screws set (2 screws, 2
stickers)
1
GT15-QBUS2,
GT15-ABUS2
Bus connection unit 1
Mounting screws set (2 screws, 2
stickers)
2
Extension interface relay board 1
Item
GT15-
QBUS
GT15-
QBUS2
GT15-
ABUS
GT15-
ABUS2
Interface
QCPU (Q Mode)
bus connection
QnA/ACPU
bus connection
* When the GOT power is on, the internal current consumption is
included in the current consumption of the GOT.
When the GOT power is off, the internal current is supplied from
the power supply of the PLC system.
Select the used bus connection unit according to the
connection target and connection position.
<Bus connection unit selection example>
(1) Select the bus connection unit according to the
connection target.
When using the bus connection, make the communication
settings to perform communication between the GOT and
PLC.Refer to GOT1000 Series Connection Manual for details
of bus connection.
3. Part Names and External Dimensions
(1) GT15-QBUS, GT15-ABUS
Connector
IN1111
OUT - 1 - 1
I/O occupied points
16 points
(I/O assignment:
16 intelligent points)
32 points
(I/O assignment:
Special 32 points)
Internal
current
consumption
(5VDC)*
0.44A 0.44A 0.12A 0.12A
Weight
0.13kg
(0.29lb)
0.14kg
(0.31lb)
0.13kg
(0.29lb)
0.14kg
(0.31lb)
When using bus connection unit, use a standard monitor OS and
communication driver of GT Designer2 Version2.15R or later.
With a standard monitor OS and communication driver of an older version,
the GOT has cannot recognize the unit to perform monitoring.
Item
GT15-
QBUS
GT15-
QBUS2
GT15-
ABUS
GT15-
ABUS2
(2) Select the bus connection unit according
to the GOT connection position.
Placed midway
: GT15-QBUS2/GT15-ABUS2
Placed at end
: GT15-QBUS/GT15-ABUS
GT15-QBUS2/GT15-ABUS2
QCPU (Q Mode), motion controller Q series
: GT15-
QBUS/GT15-QBUS2
ACPU, QnACPU, motion controller A series
: GT15-
ABUS/GT15-ABUS2
GOT
5)
63(3.27)
3(0.12)
98(3.86)
2.5
(0.10)
30.5(1.20)
21.5
(0.85)
107(4.13)
7)
1)
4)
3)
A
X
C
B
(2) GT15-QBUS2, GT15-ABUS2
Extension interface relay board
Unit: mm (inch)
Dimensions of X when the bus connection
unit is mounted to the GOT
Unit: mm (inch)
Model A B C D
GT15- QBUS
2.3
(0.09)
12
(0.47)
31.5
(1.24)
-
GT15- QBUS2
2.5
(0.10)
11
(0.43)
29
(1.14)
33.5
(1.32)
GT15- AB US
4.5
(0.18)
15
(0.59)
29.5
(1.16)
-
GT15- AB US2
4.5
(0.18)
11
(0.43)
31
(1.22)
31
(1.22)
GOT GT16 GT15
15” 19.5 (0.78) 21 (0.83)
12.1” 18 (0.71) 18 (0.71)
10.4” - 21 (0.83)
8.4”, 5.7” - 23 (0.92)
No. Name Description
1)
Bus connector
(IN side)
Connector for connecting the
bus connection cable (IN side)
2)
Bus connector
(OUT side)
Connector for connecting the
bus connection cable (OUT side)
3) Interface connector
Extension connector installed to
a front extension unit or the GOT
4) Extension connector
Extension connector to which a
back extension unit is installed
5) Mounting screw
Mounting screws fixed with a
front extension unit or GOT
6) Board fixing screw
Screw for fixing the extension
interface relay board
7) Rating plate -
A
X
5)
6)
7)
5)
4)
3
)
133(5.24)
107(4.21)
30.5(1.20)
21.5
(0.85)
2.5
(0.10)
98(3.86)
3
(0.12)
2) 1)
C
B
D
GOT
64(2.52)
24(0.94)
27.5(1.08)
4. Installation Procedure
The method for mounting and removing the bus connection unit is
explained using the GT 15 as an example.Refer to the GT16 User's
Manual for the bus connection unit mounting and removal methods
for the GT16.
(1) GT15-QBUS, GT15-ABUS
1) Power off the GOT.
2) Remove one extension unit cover of the GOT.
3) Fit the bus connection unit in the GOT case.
4) Fasten the bus connection unit by tightening its
mounting screws (2 places) with tightening torgue 0.36
to 0.48 N•m.
5) When installing an extension unit on the unit that has
been installed, remove the connector cover and the
sticker. When not installing an extension unit on the
unit that has been installed, in order to avoid receiving
electrostatic, stick accessory stickers to cover the top
of mounting screws (2 places). Keep the connector
cover fixed. Keep the sticker stuck as it is.
Sticker
A
ccessory
sticker
Connector
cover
(2) GT15-QBUS2, GT15-ABUS2
1) Power off the GOT.
2) Remove two extension unit covers of the GOT.
3) Attach the extend interface relay board to the extend
I/F-2 side on the GOT. After the installation, detach the
connector cover from the extend inter face relay
board.For GT155 , the extension interface relay
board is not needed.
4) Fit the bus connection unit in the GOT case.
5) Fasten the bus connection unit by tightening its
mounting screws (4 places) with tightening torgue 0.36
to 0.48 N•m.
6) Fasten the bus connection unit by tightening the board
fixing screws (2 places) with the tightening torque of
0.36 to 0.48 N•m.
7) When installing an extension unit on the unit that has
been installed, remove the connector cover and the
sticker. When not installing an extension unit on the
unit that has been installed, in order to avoid receiving
electrostatic, stick accessory stickers to cover the top
of mounting screws (4 places). Keep the connector
cover fixed. Keep the sticker stuck as it is.
Point
Remove the screws that fixes the extend interface relay board
before removing the unit.(Above 6))
4)
3)
Remove the connector
cover
5) 6)
Sticke
r
Accessory sticker
Accessory sticker
Connector cover
Warranty
Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.
This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
C
ountry/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061, U.S.A.
Tel : +1-847-478-2100
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
G
ermany Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
U.K Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, U.K.
Tel : +44-1707-276100
Italy Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, I-20041 Agrate Brianza., Milano, Italy
Tel : +39-039-60531
S
pain Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80,
E-08190 Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
S
outh Africa Circuit Breaker Industries Ltd.
Private Bag 2016, ZA-1600 Isando, South Africa
Tel : +27-11-928-2000
Hong Kong Mitsubishi Electric Automation (Hong Kong) Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, Hong Kong
Tel : +852-2887-8870
C
hina Mitsubishi Electric Automation (Shanghai) Ltd.
4/F Zhi Fu Plazz, No.80 Xin Chang Road,
Shanghai 200003, China
Tel : +86-21-6120-0808
T
aiwan Setsuyo Enterprise Co., Ltd.
6F No.105 Wu-Kung 3rd.Rd, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Korea Mitsubishi Electric Automation Korea Co., Ltd.
1480-6, Gayang-dong, Gangseo-ku Seoul
157-200, Korea
Tel : +82-2-3660-9552
S
ingapore Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building, Singapore 159943
Tel : +65-6470-2460
T
hailand Mitsubishi Electric Automation (Thailand) Co., Ltd.
Bang-Chan Industrial Estate No.111 Moo 4, Serithai Rd,
T.Kannayao, A.Kannayao, Bangkok 10230 Thailand
Tel : +66-2-517-1326
Indonesia P.T. Autoteknindo Sumber Makmur
Muara Karang Selatan, Block A/Utara
No.1 Kav. No.11 Kawasan Industri Pergudangan
Jakarta - Utara 14440, P.O.Box 5045 Jakarta, 11050 Indonesia
Tel : +62-21-6630833
India Messung Systems Pvt, Ltd.
Electronic Sadan NO:III Unit No15, M.I.D.C Bhosari,
Pune-411026, India
Tel : +91-20-2712-3130
A
ustralia Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan.
Page view 0
1

Summary of Contents

Page 1 - User's Manual

User's ManualThank you for purchasing the GOT1000 Series.MODEL GT15-QBUS/GT15-QBUS2/GT15-ABUS/GT15-ABUS2BUS CONNECTION UNITPrior to use, please r

Comments to this Manuals

No comments