12.3 DATA TRANSFER
The screen data, sampling data and alarm history can be transferred (read/written) between
the GOT and a peripheral unit for screen creation (personal computer).
*
**
*
Basic operation
When the screen data is transferred from the personal computer to the GOT, the screen
shown below is displayed in the GOT without regard to the screen displayed in the GOT at
that time. When transfer is finished, the screen No. 0 is displayed when the FX-PCS-DU/
WIN-E is used or the screen No. 1 is displayed when the GT Designer is used.
However, if the RS-232C port used to transfer the screen data from the personal computer
is set for connection to the PLC, the following operation should be performed to display the
DATA TRANSFER screen.
#
##
#
Important point
1) Data transfer to personal computer during sampling
Have in mind the following contents when transferring the data from/to a personal
computer while sampling is performed.
-PC
(
GOT : Sampling currently performed is aborted.
The sampling data acquired so far is saved.
-PC
'
GOT : Sampling is continued, and the acquired sampling data is saved.
[ DATA TRANSFER ] END
[ DATA TRANSFER ]
GOT <--> PC
WAI TI NG
OTHER MODE
screen is displayed.
DATA TRANSFER
screen is displayed.
DATA TRANSFER
Section 5.3
Select "DATA
TRANSFER".
The screen shown below
is displayed.
Page view 203
1 2 ... 199 200 201 202 203 204 205 206 207 208 209 ... 421 422

Comments to this Manuals

No comments