Mitsubishi 10 Specifications

Browse online or download Specifications for Split-system air conditioners Mitsubishi 10. Mitsubishi 10 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 184
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
MITSUBISHI ELECTRIC
INDICATORS and TRANSDUCERS
Mitsubishi Electric Indicators and Transducers
Y-0711 1106 (MDOC)
New publication effective Mar. 2011.
Specifications are subject to change without notice.
H1-4_OMOTE_INDICATORS/TRANSDUCERS C M Y K
H1-4_OMOTE_INDICATORS/TRANSDUCERS C M Y K
Page view 0
1 2 3 4 5 6 ... 183 184

Summary of Contents

Page 1 - INDICATORS and TRANSDUCERS

MITSUBISHI ELECTRIC INDICATORS and TRANSDUCERSMitsubishi Electric Indicators and TransducersY-0711 1106 (MDOC)New publication effective Mar. 2011.Spe

Page 2 - (Mechanical Indicators)

9Selection PrecautionsIndicator Line-up,Precautions & Specifications Selection of indicator ratingsApplication of an input exceeding a rating

Page 3 - (Transducers)

Bar-shaped IndicatorsMechanical Indicators99Outer dimensionsFig. 1 FM-210N/FR-210N9612345630Terminal layout (see table above regarding terminal code

Page 4 - Product Line-up

Mechanical Indicators100Outer dimensionsFig. 3 FM-215N/FR-215NWOpening dimensions146+10Needle (R)Needle (L)Zero-point adjuster (R)Zero-point adjuste

Page 5

Bar-shaped IndicatorsMechanical Indicators101Plate F-210N9✕28929✕28101F-213N11✕329211✕32101F-215N15✕389310✕38101F-217N25✕38938✕38101NameplateTag numbe

Page 6

Mechanical Indicators1029 characters9 characters9 characters9 characters334142212.52.52.51.54 characters 4 characters 4 characters4 characters4 charac

Page 7

Bar-shaped IndicatorsMechanical Indicators103TerminalFastening screwFastening screw (hexagonal bolt with flat groove and 5.5mm opposing sides)Mounting

Page 8

Mechanical Indicators104Tag number plateStandard screwdriverExtraction pinStandard screwdriverPressure tag number plateF-217NPivoting tag number plate

Page 9

105TransducersHigh performance realized in a compact module.Mitsubishi Electric transducersSingle function modelsT-51/T-101 SeriesPowerK Series(ordina

Page 10 - Selection Precautions

Transducers106Collective transducers T-120 SeriesMulti-use transducers that allow the input of various electricquantities from instrument transforme

Page 11 - Special Specifications

Safety PrecautionsTransducers107Safety PrecautionsPlease pay attention to the following items when using transducers.Read the instruction manual atta

Page 12 - Selection

Transducers108Precautions concerning preparation before usePlease read the following items before use.(1) TransportAvoid application of vibration and

Page 13 - Indicator Line-up

10Indicator Line-up,Precautions & SpecificationsSpecial SpecificationsSpecificationApplicationMoisture-proof treatmentSupplementaryanti-corrosion

Page 14 - Products List

Safety PrecautionsTransducers109Maintenance and inspectionPlease pay attention to the following items regardingmaintenance and inspection.Refer to p.1

Page 15 - Model Naming System

Transducers110Requests Regarding SelectionFor remote measurement, select a large output value.When performing remote measurements, as a general rule,

Page 16

Power, Instrumentation and PeripheralTransducers111Power transducersProducts listPower transducers Instrumentation/Peripheral transducersModel Name

Page 17

Transducers (Single Function)Transducers112Instrumentation transducers Peripheral transducersAC current demand(moderate time interval) (p.138)AC vol

Page 18

113TransducersT-51HAA T-101SAACurrent Transducers [Insulated]T-51/T-101 Series110VAC %50 and 60HzConsumption VA: 3110VAC %50 and 60HzConsumpti

Page 19

114TransducersT-51HSST-51/T-101 SeriesCurrent Transducers (Saturated Power) [Insulated]Suited for motor circuits, heater circuits and other circuits i

Page 20

115TransducersT-51HAV T-101SAVVoltage Transducers [Insulated]T-51/T-101 Series110VAC %50 and 60HzConsumption VA: 3110VAC %50 and 60HzConsumpti

Page 21

Transducers116Manufacturable rangeInput/Output relationshipsAuxiliary power supplyInputT-51KAV0.1~5mA50mV~5V—— 24V, 100~120V 24V±10%0.1~20mA50mV~10V

Page 22

117TransducersActive Power Transducers [Insulated]T-51/T-101 SeriesT-101HW5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A110V220V100/200V110V

Page 23

Transducers118“Inherent active power” of active power transducers* The primary-side active power (kW) mentioned here is not the full-load active powe

Page 24

11SelectionIndicator Line-up,Precautions & SpecificationsItemSeriesY-2N Series, Y-N SeriesL-N SeriesYM-210MRN SeriesLM-11MRN SeriesLM-11ZN SeriesL

Page 25 - Standards

119TransducersReactive Power TransducersT-51/T-101 SeriesT-101HVAR+10-15110VAC %50 and 60HzConsumption VA: 3*1*2BoxInput Output0~1mA4~20mA0~1

Page 26

[Insulated]Transducers120“Inherent reactive power” of reactive power transducersInput/Output relationships002.55V00.51mA500 1000var0035V0141220mA500

Page 27 - JIS Mark

121TransducersPhase Angle Transducers [Insulated]T-51/T-101 SeriesT-101HPA (U)The error increases when the input current decreaes.T-101HPA ...1/5 of

Page 28 - Common Specifications

Transducers122Input/Output relationships60°-505V-101mA0° 60°LEAD LAG60°02.55V00.51mA0° 60°LEAD LAG60°035V0141220mA0° 60°LEAD LAGDC outputAC inputDC o

Page 29

123TransducersPower Factor TransducersT-51/T-101 SeriesT-101HPF (U)5A1A5A1A5A1A5A1A5A1A5A1A5A1A5A1A3123110V220V/110V110/190V110V220V/110V110/190V110 3

Page 30

Transducers124(for Unbalanced Loads) [Insulated]Input/Output relationshipsConnection diagrams (Refer to p.156 for outer dimensions.)Specify three v

Page 31

125TransducersFrequency Transducers [Insulated]T-51/T-101 SeriesT-51HFT-101SF1.00.5110V220V110V220V1% P-P or less1s or less1% P-P or less1s or less0.3

Page 32 - Standard Scale Diagrams

126TransducersVoltage Phase Angle Transducers [Insulated]T-51/T-101 SeriesT-101SY—1~0~1mA :—5~0~5mA :—100~0~100mV :—1~0~1V :—5~0~5V :—10~0~10V :0~0.5~

Page 33

127TransducersDC Level Transducers [Non-insulated]DC level transducers input DC voltage (or current) and output DC voltage or a DC currentproportional

Page 34

128TransducersDC Reverse Transducers [Non-insulated]DC reverse transducers input DC voltage (or current) and output DC voltage or DC currentinversely

Page 35

12Indicator Line-up,Precautions & SpecificationsSelection item64✕60 (Y-206N) , 85✕75 (Y-208N) 100✕85 (Y-210N) Note 182✕82 (Y-8N) , 102

Page 36 - Outer Dimension Drawings

129TransducersIsolators [Insulated]Isolators provide insulation between DC circuits and measurement equipment, and between various sensors and control

Page 37

130TransducersHigh-speed Isolators [Insulated](Response speed: 1ms)High-speed isolators provide insulation between DC circuits and measurement devices

Page 38 - Outer Dimensional Drawings

131TransducersLimiters [Non-insulated]T-51LMOuter shapeBoxModelnameAccu-racy(grade)Input (DC) andinput resistanceAuxiliarypower supplyWeightDelivery p

Page 39 - Overall Connection Examples

132TransducersAdders [Non-insulated]Adders can be used to input several DC voltages or direct currents, perform additionaccording to the specified rat

Page 40

Resistance-bulb Temperature TransducersThese temperature transducers measure temperature by the change in resistance value ofa resistance bulb and out

Page 41

(Insulated/Non-insulated)Transducers134Input/Output relationships002.55V00.51mA50 1000 100 200C°0035V0141220mA50 1000 100 200C°DC outputInput (temper

Page 42

Thermocouple Temperature TransducersThermocouple temperature transducers use the electromotive force of the thermocouple tomeasure the temperature and

Page 43

(Insulated/Non-insulated)Transducers136Input/Output relationships002.55V00.51mA100 2000 500 1000°C100 2000 500 1000°C0035V0141220mADC outputDC output

Page 44 - DC Ammeters

First-order Lag Transducers [Non-insulated]These transducers apply a time constant to the DC input signal and delay the responsespeed.The time constan

Page 45

Transducers138

Page 46

13Products ListIndicator Line-up,Precautions & Specifications1. Rectangular Indicators (Y-2N Series, Y-N Series)Indicator typeAppearanceModel name

Page 47

139TransducersAC Current Demand Transducers (Moderate Time Interval) [Insulated]AC current demand transducers output DC current or DC voltage that is

Page 48 - DC Voltmeters

140TransducersAC Voltage Demand Transducers (Moderate Time Interval) [Insulated]AC voltage demand transducers output DC current or DC voltage that is

Page 49 - 200 (mounting pitch)

Current Transducers with Power FlowCurrent transducers receive the current and voltage of 3-phase AC circuits as input,distinguish the power flow dire

Page 50 - AC Ammeters

Detection [Insulated]Transducers142Connection diagrams (Refer to p.156 for outer dimensions.)VT321CTOUTPUTOutputAuxiliary power supplyMA MBP3P2C1C1L

Page 51 - Uniform scale

Leakage Current Transducers [Insulated]Leakage current transducers detect leakage current in AC cables using a Zero-currenttransformer (ZCT) and outpu

Page 52 - AC Voltmeters

Transducers144Model nameT-51LGNumber of units10Auxiliary power supply110VACCombined ZCTZT15BOutputVoltage or current4-20mAInputCurrent15mASpecify the

Page 53

Leakage Current Transducers These transducers detect the leakage current in AC cables using a ZCT, attenuate theharmonic component contained in the cu

Page 54 - Wattmeters

(with Built-in Low-pass Filter) [Insulated]Transducers146Outer dimensions of the ZCT unitFig. 1 ZT15B/30B/40B types Fig. 2 ZT60B/80B/100B typesEHAM

Page 55 - Terminal configuration

147TransducersVoltage (Rise/Drop) Detectors [Insulated]T-101VDLT-101VDLT-101VDH0.6kg0.6kgDrop detectionRise detection110V circuit 30~130V220V circ

Page 56

148TransducersFiltersA ripple (AC component) of approximately 5% P-P is contained in the output of K Seriesmodels. Use this filter if the ripple is t

Page 57 - Manufacturable

14Indicator Line-up,Precautions & SpecificationsIndicator typeAppearanceY- 2 NSeriesY- NSeries64✕6085✕75100✕8582✕82102✕102122✕122Operation princip

Page 58 - Varmeters

149TransducersAuxiliary PartsT-51/T-101 Series1. T-51/T-101 Series mounting partsBreaker mounting plate for distribution panel* Please specify “BH-K

Page 59

Transducers150

Page 60

151TransducersHandlingT-51/T-101 SeriesMethod for mounting inside panelsMounting work is to be performed by a person with the proper technological ex

Page 61

152TransducersSnap-fit terminal cover The terminal cover is fitted onto the partition walls of theterminal section and can be easily removed.The cov

Page 62 - Power Factor Meters

153TransducersHandlingT-51/T-101 SeriesWiringConnection work is to be performed by a person with theproper technological expertise.Connections must

Page 63 - ( )

Transducers154 Signal line connection distanceThe connection distance depends on conditions such as the output signal line specifications of the tran

Page 64

155TransducersHandlingT-51/T-101 SeriesShort-circuiting and opening of output terminalsTerminals for current output ··········· Although the termina

Page 65

156TransducersOuter DimensionsFig. 1 T-51 Series842.3310135IEC 35mm rail93Rail removal tabM4 terminal screwTerminal coverSpan adjuster115130Zero adj

Page 66

T-120M collective Multi-transducers157TransducersWith multi-transducers, the required AC electric quantities can be measured by inputting the secondar

Page 67 - Frequency Meters

[Insulated]158TransducersOperation methodThe respective setting values are displayed by consecutively pressing the button or button (ref

Page 68 - Receiving Indicators

15Products ListIndicator Line-up,Precautions & Specifications2. Wide-angle Indicators (L-N Series)AppearanceIndicator ratingsModel nameDirectOrdin

Page 69 - AC indicators

Setting Method159TransducersSetting methodi Continue set up in another setting menu or end set up. To change to another setting menu, use the

Page 70 - AC ammeters

160TransducersqChange the setting menu to indicate .wSet the unidirectional, bidirectional, or special bidirectional setting for acti

Page 71 - AC voltmeters

Setting Method161TransducersqChange the setting menu to indicate .(α: 1 for 1-phase, 2-wire system; 2 for 1-phase, 3-wire sys

Page 72 - Demand Meters

162Transducers Harmonics measurement settings (harmonic voltage, harmonic current) HARMONIC % RMS<Content (%)> <Effective value> % RMSRMS

Page 73 - AC ammeters/AC voltmeters

Transducers163Input/Output Relationships02.550V0.501.502.5Effective valueContent (%)0 10 100%2.550V1A ✕ CT ratio3A ✕ CT ratio5A ✕ CT ratioAC inputAC i

Page 74

Transducers164Outer Dimensions/Connection DiagramsNumber of units3OutputVoltage or current0-5VModel nameT-120MOuter dimensions, and names and functio

Page 75 - 1 P 2 P 3

165TransducersSpecial Application TransducersT-120HA harmonics transducers [Insulated]Usage exampleVAWHIHVHIHV: Harmonic voltage transducerTo central

Page 76 - Demand Meter Relays

166TransducersSpecificationsBetween input/output terminals as a whole and outer casing Between auxiliary power terminals as a whole and outer casingB

Page 77 - 0) is required

167TransducersSpecial Application TransducersT-120HA harmonics transducers [Insulated] 110V 220V110V 220V 440V 1100V 2200V 3300V 6600V 11kV 13.2k V16.

Page 78 - Meter Relays

168Transducers oFF (no limit): The upper-limit output is output to approx. +5% and the lower-limit output is output to approx. -5%.on (with limit):

Page 79

16Indicator Line-up,Precautions & SpecificationsIndicator typeAppearanceIndicator ratingsModel name1-phase 2-wire1-phase 3-wire3-phase 3-wire3-pha

Page 80

169TransducersSpecial Application TransducersT-120HA harmonics transducers [Insulated]Setting methodHarmonics measurement settings (harmonic voltage,

Page 81 - DC voltmeters

170TransducersNumber of units5Model nameT-120HA 4~20mAOutputVoltage or currentOuter dimensions, and names and functions of respective partsTerminal c

Page 82

171TransducersSpecial Application TransducersActive power/active energy transducers [Insulated]Outer dimensions842.3310135IEC 35mm rail93105115Rail r

Page 83

172TransducersSpecificationsItemModel nameMeasurement elementInput rangePhase-wire systemRatingsOutputAccuracyAuxiliary power supplyWeightConsumption

Page 84

173TransducersUsage/Care/Storage/Request forUsageInstall transducers in panels and use them as interface equipment for inputting DC signals correspo

Page 85 - ( )

174TransducersMaintenance and InspectionRequest for maintenance and inspectionPerform maintenance and inspection as below to ensure continued use of

Page 86

175TransducersPerformancePerformanceUsage conditionsClassification Power transducersGrade 0.5Continuous overload 120% of rated input valueImpact resis

Page 87 - Frequency meters

176TransducersPower transducersReactive power transducers Phase angle transducersT-101HPAT-101HPA(U)0.5T-101HVAR±0.5%±0.5%±0.25%(both)±0.25%—±0.5%0.25

Page 88

177TransducersPerformancePerformanceUsage conditionsClassification Power transducersGradeImpact resistanceVibration resistanceUsage temperature rangeS

Page 89

178TransducersPeripheral transducers±0.5%±0.5%0.5—T-101HAA(DS)±0.25%(both)±0.25%(both)AC current demand transducers(moderate time interval)AC voltage

Page 90

17Products ListIndicator Line-up,Precautions & SpecificationsIndicator typeAppearanceIndicator ratingsModel nameSpecial specificationsRed needleSp

Page 91

179TransducersOverall Connection DiagramsFixed-load output (K Series)(R)1Load(S)2(T)3Fig. 1 3-phase, 3-wire circuitACTVTAAVReceiver(data logger, ele

Page 92 - Earth-leakage Detectors

180TransducersConstant-current/Constant-voltage output (H Series, S Series)If the auxiliary power supply is DC, connect the + side to “MA” and the

Page 93

181TransducersGlossary of TermsFixed-load outputAn output system that can be used only with the loadresistance value connected to the output being a

Page 94 - Synchroscopes

182Transducers3-phase balanced circuitWhen loads Z.a, Z.b and Z.c that are connected to a 3-phase power supply are all equal, the respective voltages

Page 95 - Nameplate

MITSUBISHI ELECTRIC INDICATORS and TRANSDUCERSMitsubishi Electric Indicators and TransducersY-0711 1106 (MDOC)New publication effective Mar. 2011.Spe

Page 96 - Dual-element Indicators

18Indicator Line-up,Precautions & SpecificationsIndicator typeAppearanceDemand metersDemand meter relaysAC ammetersReceiving indicatorsAC ammeters

Page 97

1Overview and Features ...3Safety Precautions ...5Selection Precauti

Page 98

19Products ListIndicator Line-up,Precautions & Specifications5. Meter RelaysIndicator typeAppearanceUpper/Lower-limit settingsUpper-limit settingO

Page 99 - AC indicators

20Indicator Line-up,Precautions & SpecificationsIndicator typeAppearance1-phase2-wire3-phase3-wire3-phase4-wireRed needleForeign standardsSpecial

Page 100 - Bar-shaped Indicators

21Products ListIndicator Line-up,Precautions & SpecificationsIndicator typeAppearanceSize (mm)DC ammeters AC ammeters AC voltmeters Receiving indi

Page 101 - Fig. 4 FM-217N/FR-217N

22Indicator Line-up,Precautions & SpecificationsIndicator typeAppearanceNameplate engravingTag number plate engravingDouble scaleColored lines/ban

Page 102

Indicator Line-up,Precautions & Specifications23Glossary of TermsTerm Meaning Term Meaning⎧⎩⎧⎩Standby conditions Prior to testing, the following

Page 103 - Nameplates Tag number plates

Indicator Line-up,Precautions & Specifications24StandardsExcerpts from Japanese standards⎫⎬⎭Power supply circuitVoltage circuitCurrent circuitVolt

Page 104

25Reference Chart for Test Voltages andIndicator Line-up,Precautions & SpecificationsCorresponding test voltages according to indicator typeNote 2

Page 105 - Mechanical Indicators

26JIS MarkIndicator Line-up,Precautions & SpecificationsIndicator typeOperating circuit voltage or maximum ratingModel nameYR-8UNAA, YR-10UNAA, YR

Page 106 - Single function models

Mechanical Indicators27Common standard specifications StandardsAccuracy (grade)Usage temperature rangeUsage humidity rangeMounting attitudeScale plat

Page 107 - Collective transducers

Mechanical Indicators28Cover specificationB design cover(Munsell N 1.5 semi-gloss)Y-2N Series Y-N Series L-N SeriesClassificationG design cover (all t

Page 108 - Safety Precautions

2Overview and Features ...105Safety Precautions ...107Safety PrecautionsReq

Page 109 - Transducers

Mechanical Indicators292000400600YP-12NW3~2E 1.5 CAT3CAT3CAT35 A CT. 50/5JQ0608018110V VT. 6600/110No. F10083~2E 1.5Scale plateModel nameSer

Page 110

Mechanical Indicators30Scale plate indicationsThe following tables show the scales, including numerals, colored lines, bands and colors, used as stan

Page 111 - Requests Regarding Selection

Mechanical Indicators31Standard Scale Diagrams1a. Y-206N ordinary scale indicators 1b. Y-206N expanded scale indicatorsMaximum scale value11010010001.

Page 112 - Model Name Configuration

Mechanical Indicators323a. Y-8N and Y-10N ordinary scale indicators3b. Y-8N and Y-10N expanded scale indicators11010010001.21212012001.515150150022020

Page 113 - Transducers (Single Function)

Mechanical Indicators33Standard Scale Diagrams5a. L-110N ordinary scale indicators 5b. L-110N expanded scale indicators11010010001.21212012001.5151501

Page 114 - Ordering method

Mechanical Indicators347a. F-210N ordinary scale indicators (Class 2.5)Maximum scalevalue11010010001.21212012001.515150150022020020002.525250250033030

Page 115

Mechanical Indicators35Rectangular indicators (Y-2N Series)Depth dimension detailsIndicator typeDCAmmetersVoltmetersY-206N Y-208N Y-210NACUniform sca

Page 116

Mechanical Indicators36Rectangular indicators (Y-N Series)Depth dimension detailsY-8N Y-10N Y-12NType nameYM-8NDAYM-8NDVYS-8NAAYR-8NAAYS-8NAVYR-8NAVA

Page 117

Mechanical Indicators37Outer Dimensional DrawingsWide-angle indicators (L-N Series)FIG. 1 L-80NDepth dimension detailsFIG. 2 L-110NIndicator typeDC

Page 118

Mechanical Indicators38Overall Connection Examples1. 1-phase, 3-wire circuit102(R) (N) (T)(R) (N) (S)Voltage changeoverswitchCurrent changeoverswitch(

Page 119

3Overview and FeaturesIndicator Line-up,Precautions & SpecificationsHigh Reliability and AbundantProduct Line-upAAAAAAAADC ammeters%%%%%%%%VVVVVVV

Page 120 - Reactive Power Transducers

Mechanical Indicators39Overall Connection Examples2. 3-phase, 3-wire circuit (2CT)Note 1+C1 C1+C3 C3+C1 C1+C2 C2+C3 C3+C1 C1+C3 C31SkkRR1L3SCT3LCurren

Page 121 - [Insulated]

Mechanical Indicators403. 3-phase, 3-wire circuit (3CT)+C1 C1C3+C3+C1 C1C2C3+C2+C3C3+C3+C1 C1kkkRRRCT3L3S1S 1LNote 1Voltage changeover switchCurrent c

Page 122

Mechanical Indicators41Overall Connection Examples4. 3-phase, 4-wire circuit+C1 C1+C1 C2C3+C3+C1 C1C2C3+C2C2+C3C3+C22L+C33L2S3S+C1 C11SkkkRRR1LCTNote

Page 123

Mechanical Indicators42

Page 124 - Power Factor Transducers

DC AmmetersMechanical Indicators43SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)Scale length (mm)Weight (kg)Indi

Page 125

Mechanical Indicators44Table of maximum allowable values of lead wires for DC ammeters combined with shuntsModel nameYM-206NDA, YM-208NDAYM-210NDAYM-

Page 126

DC AmmetersMechanical Indicators45SpecificationsAccuracyRated voltageRated currentStructureVoltage testInsulation resistanceGrade 0.5 Percentage wi

Page 127

Mechanical Indicators46Table of dimension variations (rated voltage: 60mV)1, 2, 3, 510, 15, 20, 25, 3040, 5060, 75, 100150200250300400500600750100012

Page 128

DC VoltmetersMechanical Indicators47SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)Scale length (mm)Weight (kg)In

Page 129

Mechanical Indicators48Dual-range indicatorsDual-range indicators with a maximum scale of 600V or less are manufacturedwith the GR-2 multiplier as an

Page 130 - Isolators [Insulated]

4Indicator Line-up,Precautions & SpecificationsYR-8UN82✕99YR-10UN102✕119YR-12UN122✕139YR-UN SeriesIndicators with changeover switchVVVAAAAVAVkWkva

Page 131 - (Response speed: 1ms)

AC AmmetersMechanical Indicators49SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)FrequencyScale length (mm)Consum

Page 132 - Limiters [Non-insulated]

Mechanical Indicators50SpecificationsDirect indicator Note 1Indicatorcombined with CTSize (width ✕ height) mmModel nameOperation principleAccuracy (

Page 133 - Adders [Non-insulated]

AC VoltmetersMechanical Indicators51SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)FrequencyScale length (mm)Cons

Page 134 - Applications

Mechanical Indicators52SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)FrequencyScale length (mm)Weight (kg)Indica

Page 135 - (Insulated/Non-insulated)

WattmetersMechanical Indicators53SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)FrequencyScale length (mm)Weight

Page 136

OUTPUTINPUTNameplateP 1 P2 P 3C3+C3+C1C113011510070R3R31006 6M4 terminal screw12 126 612 121.2891131615011.512.512.511.5100Mechanical Indicators54Spe

Page 137

WattmetersMechanical Indicators55Connection diagrams( )CTLoadT-150 rectifierfor 1-phase, 2-wiresystem wattmeter+PPC+CFig. 1

Page 138

Mechanical Indicators56Wattmeter Scale Selection Reference TableAlthough the maximum scale of a wattmeter can be determined by VT ratio ✕ CT ratio ✕

Page 139

VarmetersMechanical Indicators57SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)FrequencyScale length (mm)Weight (

Page 140 - T-101HAA (DS)

Mechanical Indicators58SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)Scale length (mm)Weight (kg)Indicator ratin

Page 141 - T-101HAV (DS)

5Safety PrecautionsIndicator Line-up,Precautions & SpecificationsPlease follow the following precautions when using Mitsubishi Electric products a

Page 142 - Application example

VarmetersMechanical Indicators59Connection diagramsPPP1231132233CCC+C1+C2+CCTLoad( )T-150 rectifierfor 3-phase, 3-wiresyste

Page 143 - Detection [Insulated]

Mechanical Indicators60Varmeter Scale Selection Reference TableAlthough the maximum scale of a varmeter can be determined by VT ratio ✕ CT ratio ✕ in

Page 144 - T-51LG ZCT

Remarks (1) Indicators with a LEAD 0–1–0 LAG scale can also be manufactured; however, measured values forpower factors of 0.5 or less are for referen

Page 145 - Reference

Mechanical Indicators62+P+CPCCTLoadFig. 1 YP-12NPF, YP-15NPF and LP-110NPF(combined with CT)+P+CPCCTVTLoadNote 1Fig. 2 YP-12NPF and LP-110NPF(combined

Page 146 - Leakage Current Transducers

(1) A LEAD 0~1~0 LAG scale can also be manufactured; however, the measured power factor values of 0.5 or less are for reference only.(2) Please specif

Page 147 - Fig. 1 T-51LGF

Mechanical Indicators64Size (width ✕ height) mmModel nameOperation principleAccuracy (grade)ScaleFrequencyScale length (mm)Weight (kg)Indicator rating

Page 148 - <1-phase/3-phase>

65Mechanical IndicatorsPower Factor MetersConnection diagrams( )123CTLoad+C1+C3C1C3P1P3T-150 rectifierfor 3-phase, 3-wiresy

Page 149

Frequency MetersMechanical Indicators66SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)Scale length (mm)Weight (kg

Page 150 - Auxiliary Parts

Receiving IndicatorsMechanical Indicators67Receiving indicators indicate the quantity measured when an electrical signal is received from the transmit

Page 151

Mechanical Indicators68AC indicatorsConsumption current, consumption VA, or voltage drop64✕60YR-206NRI5585✕75YR-208NRI70100✕85YR-210NRI8582✕82YR-8NRI

Page 152 - Handling

4. Precautions concerning preparation before usePlease read the following carefully before use.(1) TransportationBe sure to prevent the indicators fr

Page 153 - Snap-fit terminal cover

With YR-8UNAA and 10UNAA, the 3-terminal-combined-with-CT model is of the movable iron core type.The 4-terminal configuration can be manufactured for

Page 154

Mechanical Indicators70AC voltmetersUsing AC voltmeters with changeover switches, the voltages between the respective wires of a3-phase, 3-wire system

Page 155

71Mechanical IndicatorsDemand MetersAppearanceSize (width ✕ height)AC ammetersAC voltmetersDemand metersReceiving indicatorsWith max. value needleDema

Page 156

Mechanical Indicators72SpecificationsIndicator typeModel nameOperation principleAccuracy (driving needle) (grade)Consumption VAMarker needle resetWei

Page 157 - Outer Dimensions

73Mechanical IndicatorsSpecificationsIndicator typeModel nameOperation principleAccuracy (driving needle) (grade)FrequencyWattemeters Receiving indic

Page 158 - Analog output patterns

Mechanical Indicators74Fig.1 T-150 rectifier (for wattmeter) Fig. 2 T-150LB DC amplifierOuter dimensions of accessoriesFig. 1 LB-11ZNW and LB-11YN

Page 159

75Mechanical IndicatorsSpecifications Needle and relay contact operationsIndicator typeModel nameOperation principleAccuracy (grade)AC ammetersLB-11

Page 160 - Setting Method

Demand Meters/Demand Meter RelaysMechanical Indicators76Time interval and indications of demand metersThe time interval (t0) of a demand meter refer

Page 161

Meter RelaysMechanical Indicators77Products listSize (width ✕ height) mm Scale length (mm)AC Upper/Lower-limit settingRectangular indicator100✕8372I

Page 162

Mechanical Indicators78Needle position and output relay operationNeedle positionContact operation mode of the lower-limit output relay(a contact exam

Page 163

7Safety PrecautionsIndicator Line-up,Precautions & Specifications5. Usage precautionsPlease conform to the following during use.6. Precautions con

Page 164 - Input/Output Relationships

Meter RelaysMechanical Indicators79SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)Scale length (mm)Weight (kg)R

Page 165 - Ordering method

Mechanical Indicators80SpecificationsRectangular indicatorsUpper/Lower-limit settingWide-angle indicatorsUpper-limit setting Upper/Lower-limit settin

Page 166 - Features

Meter RelaysMechanical Indicators81SpecificationsRectangular indicators Wide-angle indicatorsUpper/Lower-limit settingMaximum scale value/5A (indicat

Page 167 - Operation method

Mechanical Indicators82SpecificationsConsumption VA and delivery period classification50 and 60Hz10, 30, 50V75, 100V150V300VMaximum scale valueVT rat

Page 168 - Setting Method

Meter RelaysMechanical Indicators83SpecificationsIndicator rating and delivery period classificationWattmetersRectangular indicators2.5720.7YM-210MRN

Page 169

Mechanical Indicators84OUTPUTINPUTNameplateP 1 P 2 P 3C3+C3+C1C113011510070R3R31006612 126612 121.289M4 terminal screw1131615011.512.512.511.5100+–T-1

Page 170 - Setting method

85Mechanical IndicatorsMeter RelaysPower factor metersSpecificationsIndicator rating and delivery period classificationYM-210MRNPF YM-210MRHNPF YM-21

Page 171 - Ordering method

Mechanical Indicators86SpecificationsYM-210MRNF YM-210MRHNF LM-11MRNF LM-11MRHNF100✕83 110✕110Transducer1720.745~75Hz, 170~190Hz85~110Hz, 360~440HzCi

Page 172 - WWH WWH WWH WWH

Meter RelaysMechanical Indicators87SpecificationsIndicator rating±0.5mA1mA10mA4-20mA (zero-suppressed)1, 5, 10VDeliveryperiodCurrent inputVoltag

Page 173 - 2-P3 2.5VA

Mechanical Indicators88Precautions When Handling Meter RelaysFor meter relays, always keep the auxiliary power supply on. The consequences of turnin

Page 174 - Storage

8Indicator Line-up,Precautions & Specifications8. Storage precautions(1) Do not store indicators for long periods in the following locations. Lon

Page 175 - Maintenance and Inspection

Indicators with Maximum and Minimum NeedlesMechanical Indicators89SpecificationsSize (width ✕ height) mmDC ammeter110✕110LM-11ZNDALM-11YNDAMovable co

Page 176 - Performance

Mechanical Indicators90Example of using one LM-11ZNAV (LM-11YNAV) unit Example of using three LM-11ZNAV (LM-11YNAV) unitsINPUTOUTPUTNameplate130115100

Page 177

Earth-leakage DetectorsMechanical Indicators91LM-11NGDAn earth-leakage detector detects an earth fault of an ungrounded 3-phase 3-wire circuit and en

Page 178

Mechanical Indicators92Connection and VT ratio of EVT to be combined with a ground voltmeter (LM-11ZNAV or 11-YNAV) and an earth-leakage detector (LM

Page 179

SynchroscopesMechanical Indicators93SpecificationsL1-11NSYA synchroscope indicates the synchronization point (scale center) when the frequencies and

Page 180 - Overall Connection Diagrams

Mechanical Indicators94OUTPUTINPUTNameplate13011510070R3R310066M4 terminal screw12 126 612 121.2891131615011.512.512.511.5100AA1A2BB1B2 L2L1C DEFFig.

Page 181 - A” and the – side to “MB”

Dual-element IndicatorsMechanical Indicators95SpecificationsSize (width ✕ height) mmModel nameOperation principleAccuracy (grade)Scale length (mm)Wei

Page 182 - Glossary of Terms

Bar-shaped IndicatorsMechanical Indicators96ApplicationsProducts listOptimal as indicators for various process controls in power generating/transfo

Page 183

(1) Models that can be mounted vertically and horizontally can be manufactured; please specify if required.(2) Use the following table to select the a

Page 184

Mechanical Indicators98Specifications1.4V0.2VA100✕30FR-210SN130✕36FR-213SN150✕40FR-215SN170✕42FR-217SNRectifier1.5Consumption VA or voltage dropDeliv

Comments to this Manuals

No comments