Mitsubishi FDC100VN Specifications Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
54
Previous New
Due to optimization of outlet design of air flow with our
new advanced technology, sufficient air flow is secured
and long reach of air flow is realized. (FDT)
For person who is far
from the indoor unit
For both persons who are
feeling hot or cold
Can cool both the kitchen
and the guests
Expansion of outlet air flow area realizes
reduction of pressure loss caused by air flow
in the indoor unit. Load of fan motor is
decreased and efficiency is increased.
Reduction of air flow pressure loss
Previous
New
Shape of heat exchanger
365mm
298
mm
FDT125~140
18%
reduction!!
Increase of heat transfer efficiency
Applying high efficient piping in heat exchanger and
optimization of heat exchanger (2parts 1part)
increases heat transfer efficiency.
Individual flap control system
According to room temperature conditions, four
directions of air flow can be controlled individually by
following Flap control system.
As individual flap control is available even after
installation, installation area became wider than before.
The thinnest design
Thanks to new design of heat exchanger changed from 2 parts to 1 part, the height of
indoor unit is reduced drastically.
High efficiency
External Static Pressure (E.S.P.) control (FDU71~140)
Reduction of sound pressure level
Transparent inspection window
Selected
upper position
Max swing
range
Selected
lower position
Flap control system
The flap can swing within the range of upper and
lower flap position selected with wired remote control.
(this system is applied for FDEN, SRK type also)
*
Wireless remote control and RCH-E3 is not applicable to the Individual flap
control system and the Flap control system.
Ceiling Cassette -4way- Indoor units
FDT
.
FDTC FDU
Duct Connected -High Static Pressure-
Keep the same
air flow volume
Longer DuctDuct
Ceiling
New
FDU
Duct
External Static Pressure (E.S.P.) can
be set by E.S.P. button.
*Range of 80~150 Pa is set at ex-factory default.
Range of 10~200 Pa is available by setting SW8-4 switch on at site.
E.S.P. button
RC-E5
Setting No.
E.S.P.
No.8
80Pa
No.9
90Pa
No.10
100Pa
No.11
110Pa
No.12
120Pa
No.13
130Pa
No.14
140Pa
No.15
150Pa
case1 case2
<Expansion of external static pressure range>
<Thin design> <Reduction of weight>
Current
10~130Pa
New
10~200Pa
FDU71/100 37 25 12dB less!!
New
New
Lo mode
(FDU71VF1, in the Lo mode)
Current
Current
FDU125/140 38 30 8dB less!!
0510 15 20 25 30 35 40 dB(A)
12dB less!!
You can set External Static Pressure (E.S.P.) by method
of manual setting on remote control. Indoor unit will
control fan-speed to keep rated air
flow volume at each fan speed setting.
You can set required E.S.P. by wired
remote control that calculated with the
set air flow rate and pressure loss of
the duct connected.
Dirt condition of the bottom of a drain pan can be
checked through this transparent inspection
window without removing drain pan.
FDU71 297 280 17mm less!!
New
Current
FDU100/125/140 350 280 70mm less!!
Thin design & Reduction of weight
FDU71 40 34 6kg less!!
New
Current
FDU100/125/140 63 34 29kg less!!
FDUM has the same E.S.P. control (refer to page 14) and Transparent inspection window.
FDUM
DUCT CONNECTED -Middle Static Pressure-
FDUM
280mm
Cleaning
not required
A cross is visible
An outer
circle is visible
Cleaning
required
invisible
invisible
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 51 52

Comments to this Manuals

No comments