Mitsubishi MSZ-A30YV Operations Instructions Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
FAN
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL
COOL
DRY
WIDE VANE
LONG
HEAT
I FEEL... AUTO OPERATION
Details of operation
According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY or
HEAT. However, when operation is started again within 2 hours after it is stopped, the same operation mode before the
operation is stopped is selected. The operation mode selected first is not changed even if the room temperature changes.
If the operation mode does not match the room condition, select the appropriate operation mode by pressing the
MODE
button.
Details of auto operation
Operation state
This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.
This shows that the room temperature is approaching the
target temperature.
(In case of outdoor unit MXZ series only)
Please refer to Information for multi system air conditioner.
(Page 7)
Indication
Difference between target
temperature and room temperature
About 2°C or more
About 2°C or less
Description of I FEEL... mode
Room temperature
Operation mode Target temperature
when started
(initial state)
About 25°C or higher COOL About 24°C
About 25°C - 23°CDRY
About 23°C or lower HEAT About 26°C
NOTE:
COOL: When the room temperature is 2°C higher than the set temperature, the set temperature may not be
changed since the air conditioner is operating to reach the target (set) temperature. In this case, please
wait until the room temperature drops to within 2°C of the set temperature and then change the set
temperature.
HEAT: When the room temperature is 2°C lower than the set temperature, the set temperature may not be
changed since the air conditioner is operating to reach the target (set) temperature. In this case, please
wait until the room temperature rises to within 2°C of the set temperature and then change the set
temperature.
Details of display on the indoor unit
The operation indicator at the right side of the indoor unit indicates the operation state.
Operation indicator lamp
ON/OFF
FAN
TOO
WARM
TOO
COOL
VANE
MODE
ECONO COOL
STOP
START
HR.
MIN.
I FEEL
COOL
DRY
AMPM
CLOCK
˚C
AMPM
WIDE VANE
LONG
HEAT
RESET CLOCK
Operation Indicator
Lighted
Blinking
Not lighted
With the (I FEEL...) auto operation mode, the optimum room condition can be set automatically
with a one-touch operation.
To start operation:
Press the
ON/OFF
button.
When the (I FEEL...) mode is selected, the air conditioner is automatically
controlled at the optimum temperature.
To stop operation:
Press the
ON/OFF
button.
If you feel slightly warm:
Press the
TOO
WARM
button to lower the temperature.
One press lowers the temperature by about 1°C.
If you feel slightly cool:
Press the
TOO
COOL
button to raise the temperature.
One press raises the temperature by about 1°C.
When
(I FEEL...) is not selected, press the
MODE
button until it is set.
Each time the button is pressed, the operation mode is changed
in sequence:
(I FEEL...) (COOL) (DRY)
(HEAT)
Description of AUTO RESTART FUNCTION
These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main
power.
If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.
If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.
If the unit is operated in I FEEL... before power failure, the operation mode (COOL, DRY or HEAT) is not stored in the
memory. When the main power is turned on, the unit decides the operation mode by the initial room temperature at
restart and starts operation again.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 15 16

Comments to this Manuals

No comments