Purpose:
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
Purpose
Measuring
Instrument
Test Point
Measuring
Range
Input Signal
Ext. Trigger
Input Terminal
Symptom:
MODELS: WS-55859 / WS-55909 / WS-65869 / WS-65909 / WS-73909
-----
-----
------
------
Monoscope
Video Input
[Video Circuit]
11. Black Level
To set the black level of the picture.
Excess or insufficient brightness.
1. Supply a Monoscope signal to a Video Input.
2. Activate the Adjust Mode, VC Function.
3. Adjust Item 2 SBRT so the 0% and 10% black levels on the gradation scale
are the same.
4. Press ENTER to save data.
7. Exit the Service Mode.
40% 30% 20% 10%
50% 0% 0% 0%
60% 70% 80% 90%
GRADATION SCALE
DC ma meter
DT connector pins 7 & 8
------
-----
Grayscale
RF Input
To set overall beam current to its optimum level.
Excess or insufficient contrast.
Note: Activate the Expand mode (full screen).
1. Supply a Grayscale signal to a RF Input.
2. Activate the Adjust Mode, VC Function.
3. Select Item 1 SCT, signal level automatically reduces.
4. Connect a 3ma DC meter between DT connector pins 7 and 8. Positive lead to
pin 7.
5. Adjust Item 1 SCT for 615µA ±10µA (645µa ±10µa on the WS-73909).
6. Remove the meter.
7. Save data and Exit the Service Mode.
[Video Circuit]
12. Sub Contrast
CIRCUIT ADJUST MODE
Activate .. MENU-0-1-5-7
Function .....AUDIO
Item No. ..VIDEO
Ad
j
ust Data ..ADJUST
Save Data . ENTER
Exit ..MENU
(
twice
)
CIRCUIT ADJUST MODE
Activate .. MENU-0-1-5-7
Function .....AUDIO
Item No. ..VIDEO
Ad
j
ust Data ..ADJUST
Save Data . ENTER
Exit ..MENU
(
twice
)