CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················3
3. SPECIFICATION·················································3
4. NOISE CRITERIA CURVES·······························5
5. OUTLINES AND DIMENSIONS ·························6
6. WIRING DIAGRAM ············································7
7. REFRIGERANT SYSTEM DIAGRAM················8
8. PERFORMANCE CURVES································9
9. ACTUATOR CONTROL····································19
10. SERVICE FUNCTIONS·····································20
11. TROUBLESHOOTING······································20
12. DISASSEMBLY INSTRUCTIONS·····················27
13. PARTS LIST······················································30
14. RoHS PARTS LIST···········································32
HFC
utilized
R410A
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
MUH-GA20VB
MUH-GA25VB
MUH-GA35VB
Wireless type
Models
MUH-GA20VB-
MUH-GA20VB-
MUH-GA25VB-
MUH-GA25VB-
MUH-GA35VB-
MUH-GA35VB-
E3
E1
E2
E1
E2
E1
SERVICE MANUAL
OUTDOOR UNIT
Indoor unit service manual
MSC-GAVB Series (OB385)
MSC-CAVB Series (OB393)
MSC-CBVB Series (OB439)
No. OB387
REVISED EDITION-B
Please void OB387 REVISED EDITION-A.
Revision B:
MUH-GA35VB - has been added.
E3
NOTE:
• This service manual describes technical data of outdoor units.
• RoHS compliant products have <G> mark on the spec name plate.
For servicing of RoHS compliant products, refer to the RoHS Parts List.
OB387B-1.qxp 07.5.23 2:47 PM Page 1
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - OUTDOOR UNIT

CONTENTS1. TECHNICAL CHANGES ····································22. PART NAMES AND FUNCTIONS······················33. SPECIFICATION··················

Page 2 - TECHNICAL CHANGES

10MSC-GA20VB MUH-GA20VB MUH-GA35VB MSC-GA35VBMUH-GA25VB MSC-GA25VB8.57.87.16.45.85.110.09.28.37.56.86.011.010.09.18.27.46.520.018.516.915.413.912.310.

Page 3 - SPECIFICATION

118-2.OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENTCOOL operation① Both indoor and outdoor unit are under the same temperature/humidity condition.➁ Ai

Page 4

12HEAT operationCondition indoor:Dry bulb temperature 20.0°CWet bulb temperature 14.5°COutdoor:Dry bulb temperature 7,15,20°CWet bulb temperature 6,12

Page 5 - NOISE CRITERIA CURVES

13MSC-GA20VB : MUH-GA20VBPERFORMANCE DATACOOL operation (230V)21 18 2.70 1.51 0.56 572 2.59 1.45 0.56 601 2.48 1.39 0.56 629 2.39 1.34 0.56 65821 2

Page 6 - OUTLINES AND DIMENSIONS

14MSC-GA20VB : MUH-GA20VB PERFORMANCE DATACOOL operation (230V)21 18 2.25 1.26 0.56 701 2.07 1.16 0.56 744 1.99 1.11 0.56 75821 20 2.37 1.04 0.44

Page 7 - WIRING DIAGRAM

15MSC-GA25VB : MUH-GA25VB PERFORMANCE DATACOOL operation (230V)21 18 3.11 1.62 0.52 656 2.98 1.55 0.52 689 2.86 1.49 0.52 722 2.76 1.43 0.52 75421

Page 8 - REFRIGERANT SYSTEM DIAGRAM

16MSC-GA25VB : MUH-GA25VB PERFORMANCE DATACOOL operation (230V)21 18 2.60 1.35 0.52 804 2.39 1.24 0.52 853 2.29 1.19 0.52 86921 20 2.73 1.09 0.40

Page 9 - PERFORMANCE CURVES

17MSC-GA35VB : MUH-GA35VB PERFORMANCE DATACOOL operation (230V)21 18 4.11 1.97 0.48 872 3.94 1.89 0.48 916 3.78 1.81 0.48 959 3.64 1.75 0.48 10032

Page 10 - Wet-and dry-bulb

18MSC-GA35VB : MUH-GA35VB PERFORMANCE DATACOOL operation (230V)21 18 3.43 1.65 0.48 1068 3.15 1.51 0.48 1134 3.03 1.45 0.48 115521 20 3.61 1.30 0.

Page 11

19MSC-GA20VB : MUH-GA20VB PERFORMANCE DATAHEAT operation (230V)MSC-GA25VB : MUH-GA25VB OUTDOOR WB(:)INDOOR-10 -5 0 5 10 15 20DB(:)Q INPUT Q

Page 12 - MUH-GA35VB

TECHNICAL CHANGES21MUH-A07YV- ➔MUH-GA20VB-1. Indication of capacity has been changed. (BTU base ➔ kw)2. Dimension of outdoor unit has been changed. (W

Page 13 - MSC-GA20VB : MUH-GA20VB

20TROUBLESHOOTING113. Troubleshooting procedure1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate a

Page 14

2111-2. Instruction of troubleshootingStartIndoor unit operates.Outdoor unit doesn't operate.Indoor unit doesn't receive the signal from re

Page 15 - MSC-GA25VB : MUH-GA25VB

22AACheck of outdoor unitCompressor and/or outdoor fan motor doesn’t operate.YesCompressor doesn't operate.YesYesIs there 230V AC between 3 on th

Page 16

23BB Check of outdoor unitDoes compressor stop?NoYesIs there 230V AC between 3 on thecompressor contactor (52C) and N on the outdoor terminal block (

Page 17 - MSC-GA35VB : MUH-GA35VB

24DDHow to check mis-wiring and serial signal errorSerial signal error is indicated.(0.5-sec. ON, 0.5-sec. OFF)1. Turn OFF the power supply(indoor/out

Page 18

25EE Check of outdoor thermistorMeasure resistance between CN 661 1 and 2.NoYe sReplace the thermistor.Defrost thermistor (RT61)Reconnect CN661.Turn

Page 19 - ACTUATOR CONTROL

26MUH-GA20VB MUH-GA25VBMUH-GA35VB Outdoor deicer P.C. boardCN711Outdoor fan motor 230V ACCN721R.V. coil230V ACF61Fuse2A/250V}}CN661 1-2Defrost thermis

Page 20 - SERVICE FUNCTIONS

27DISASSEMBLY INSTRUCTIONS12MUH-GA20VB MUH-GA25VB MUH-GA35VB OUTDOOR UNITOPERATING PROCEDURE PHOTOS1. Removing the cabinet(1) Remove the screws of

Page 21

283. Removing the propeller and the outdoor fan motor(1) Remove the cabinet. (Refer to 1.)(2) Remove the propeller nut.(3) Remove the propeller.NOTE :

Page 22 - Check of outdoor unit

29OPERATING PROCEDURE PHOTOS4. Removing the compressor(1) Remove the cabinet. (Refer to 1.)(2) Remove the relay panel.(3) Remove the soundproof felt.(

Page 23

3PART NAMES AND FUNCTIONS2( )Air inletAir outletDrain outletPipingDrain hoseback : MUH-GA20VBback and side : MUH-GA2

Page 24

30PARTS LIST (non-RoHS compliant)132235221115MUH-GA20VB MUH-GA25VB MUH-GA35VB 417 14192018136 78910 11121623This figure shows MUH-GA20VB.2413

Page 25 - Check of outdoor thermistor

31Part numbers that are circled are not shown in the illustration.123456789101112131415161718192021222324252627282930313233E02 904 630E02 905 630E

Page 26

RoHS PARTS LIST (RoHS compliant)32142235221115417 14192018136 78910 11121623This figure shows MUH-GA20VB.24MUH-GA20VB MUH-GA25VB MUH-GA35VB 14

Page 27 - DISASSEMBLY INSTRUCTIONS

331234567891011121314151617181920212223242526272829E12 904 630E12 905 630E12 906 630E12 A86 630E12 904 301E12 905 301E12 899 232E12 903

Page 28 - OPERATING PROCEDURE PHOTOS

34OB387B-2.qxp 07.5.23 2:50 PM Page 34

Page 29

35OB387B-2.qxp 07.5.23 2:50 PM Page 35

Page 30 - 13-1. OUTDOOR UNIT

CCCopyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO.,LTDDistributed in May 2007. No.OB387 REVISED EDITION-B 6Distributed in May 2006. No.OB387 REVISED

Page 31

4CapacityDehumidificationOutdoor air flowPower outletRunning currentPower inputAuxiliary heaterPower factorStarting currentCompressor motor currentFan

Page 32 - 14-1. OUTDOOR UNIT

5NOISE CRITERIA CURVES490807060504030201063 125 250 500 1000 2000 4000 8000APPROXIMATETHRESHOLD OFHEARING FORCONTINUOUSNOISENC-60NC-50NC-40NC-30NC-20N

Page 33

6OUTLINES AND DIMENSIONS51069800302.5500 Bolt pitch for installation15022.3Handle550280164.599.5170.523Service panelService port285344.544400Air inAir

Page 34

7WIRING DIAGRAM6SYMBOLT61TB1,TB221S452CSYMBOLMFNR61RT61SR61,SR62SYMBOLC1C65DSARF61MCNAMENAME NAMECOMPRESSOR CAPACITOROUTDOOR FAN CAPACITORSURGE ABSORB

Page 35

8REFRIGERANT SYSTEM DIAGRAM7OUTDOOR UNIT(with heat insulator)Refrigerant pipe [ 9.524-way valveDefrostthermistorRT61MufflerOutdoorheatexchangerCapilla

Page 36

9Length of connecting pipe : mIndoor unitGas 0.43Liquid 0.5 Piping size O.D : mmLiquid6.35Gas9.52Outdoor unitGas 0Liquid 0ModelMUH-GA20VBMUH-GA2