Mitsubishi MOTION CONTROLLERS Q172DCPU Instruction Manual Page 100

  • Download
  • Add to my manuals
  • Print
  • Page
    / 316
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 99
4 - 69
4 POSITIONING DEDICATED SIGNALS
4.2.7 Cam axis monitor devices
(1) Execute cam No. storage register (D1241+10n) ... Monitor device
(a) This register stores the cam No. currently being controlled.
(b) Cam No. of the execute cam No. storage register is held until next cam is
executed. (Cam No. is not cleared, even if cam control is completed.)
(2) Execute stroke amount storage register (D1242+10n, D1243+10n)
.........….. Monitor device
(a) This register stores the cam No. currently being controlled.
(3) Current value within 1 cam shaft revolution storage register
(D1244+10n, D1245+10n) ....................................... Monitor device
(a) This register stores the current value within 1 cam shaft revolution set in the
parameter.
The current value is a ring address of "0 to [Number of pulses per cam shaft
revolution (Nc)-1]".
0
(N
C
-1)
Page view 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 315 316

Comments to this Manuals

No comments