CHARGING SYSPE
8-89
lELll2
,
l
Diode trio test
Check three diodes for continuity by connecting a circuit tester
to both ends of each diode. If there is no continuity or no
continuity in both directions, diode is defective and heatsink
assembly must be replaced.
REPLACEMENT OF BRUSH
A brush worn away to the limit is replaced using the procedure
below.
(1) Remove the pigtail solder and take out the old brush and
spring.
(2) Install brush spring and new brush in brush holder.
(3) Insert the brush to where there is a space 2-3 mm
(.079-,118 in.) between the limit line and the end of the brush
holder.
(4) While maintaining the position of the step, solder the pigtails
to the end of the brush holder.