Mitsubishi SKM32ZA Specifications Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
149
Use cables for interconnection wiring to avoid loosening of the wires.
CENELEC code for cables Required field cables.
H05 RNR4G1.5 (Example)
H Harmonized cable type
05 300/500 volts
R Natural-and/or synth. rubber wire insulation
N Polychloroprene rubber conductors insulation
R Stranded core
4 Number of conductors
G One conductor of the cable is the earth conductor (yellow/green)
1.5 Section of copper wire (mm
2
)
a) Open the suction grille, then remove the lid.
b) Remove the wiring clamp.
c) Pass the connecting wire to terminal block from behind of indoor unit.
d) Connect the connecting wire securely to the terminal block.
1 Connect the connection wire securely to the terminal block. If the
wire is not affixed completely, contact will be poor, and it is danger-
ous as the terminal block may heat up and catch fire.
2 Take care not to confuse the terminal numbers for indoor and outdoor
connections.
3 Affix the connection wire using the wiring clamp.
e) Fix the connecting wire by wiring clamp.
f) Attach the lid.
g) Close the suction grille.
Earth
Wiring
Terminal
Terminal block
Wiring clamp
Connecting
Wiring
Terminal
Block Cover
Cover
Lid
Pipe
Drain hose
¡ Tape only the portion that runs through the wall.
Always tape the crossover wires with the pipe.
¡ Hold the bottom of the pipe and change its direction
before stretching it and shaping it.
4) Shaping the pipe and drain hose
[Shaping the pipe] [Taping of the exterior]
a) Remove the lid.
b) Remove the terminal block cover.
c) Connect the connection wire securely to the terminal block.
1 Connect the connection wire securely to the terminal block. If the
wire is not affixed completely, contact will be poor, and it is danger-
ous as the terminal block may heat up and catch fire.
2 Take care not to confuse the terminal numbers for indoor and outdoor
connections.
3 Affix the connection wire using the wiring clamp.
d) Attach the terminal block cover.
e) Attach the lid.
SKM22, 25, 28, 32, 40 models.
SKM50 model
Pull the part maked « while
pushing its part in the direction
of allow so as to dismount
it.(Dismount or detach it for
each side).
3) Mounting of interconnecting wires (Field wiring)
¡ SKM22, 25, 28, 32, 40 models.
¡ SKM50 model
Suction grille
Connecting wire
Wiring clamp
Terminal
block
Screw
Lid
Outdoor side
5°
ø65
Indoor side
Wall thickness × 1.5cm
Sleeve
Sleeve Inclined plate
Sealing plate
Putty
Pipe
Assembled state
¡ Drill a hole with a 65 whole
core drill.
¡ When the pipe is connected at the rear, cut off the lower and the right
side portions of the sleeve collar (as shown by the broken line.)
2) Drilling of holes in the wall and fixture of sleeve
¡ The connecting wires may touch the metal inside the wall and cause danger so it is necessary to always use the sleeve.