Item
Model
SCM68ZA
Cooling capacity W 6800 (1800~7000)
Heating capacity W 7300 (2000~7600)
Power source 1 Phase 220/230/240V 50Hz
Power consumption
Cooling
W
3230 (500~3400)
Heating 2950 (500~3400)
Running current
Cooling 17.0/16.6/16.1
Heating
A
17.0/16.6/16.1
Sound level Cooling : 50/50/51 Heating : 52/52/52
Noise level
Power level
dB
Cooling : 64/64/65 Heating : 66/66/66
Exterior dimensions
Height × Width × Depth
mm
640 × 850 × 290
Color Stucco white
Net weight kg 53
Refrigerant equipment
Compressor type & Q’ty
RM5516GA4
×
1
Motor kW 1.5
Starting method Direct start
Refrigerant control Capillary tubes + Electric expansion valve + Thermal expansion valve
Refrigerant kg R22 1.95 (Pre-charged up to the piping length of 30m)
Refrigerant oil R 0.6 (BARREL FREEZE 32SAM)
Air handling equipment
Fan type & Q’ty
Propeller fan × 1
Motor W 37
Air flow (at high) CMM 40
Shock & vibration absorber Rubber (for compressor)
Safety equipment
Size × Core × Number mm (in)
Liquid line: φ 6.35 (1/4) × 3
Gas line: φ 9.52 (3/8) × 2 + φ 12.7 (1/2) × 1
Connecting method Flare connecting
Attached length piping
Insulation Necessary (Both Liquid & Gas lines)
Power source supply Terminal block (Screw fixing type)
Size × Core number 1.5 mm
2
× 4 cores (Including earth cable)
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Union : (φ 9.52 / φ 12.7) × 2, (φ 12.7 / φ 9.52) × 1
Installation sheet, Manual instruction
Indoor units to be combined
(2) Outdoor unit
Model SCM68ZA
Compressor overheat protection, Overcurrent protection
Power transistor overheat protection
Notes (1) The data are measured at the following conditions.
SKM22, 25, 28, 32, 40, 50 type
SRRM40 type
Refrigerant
piping
Connection
wiring
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB
DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC ISO-T1, JIS C9612
Heating 20ºC 7ºC 6ºC ISO-T1, JIS C9612
(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.
(3) If the piping length exceeds 30 m, additional charging is required. (20g/m)