1. SPECIFICATIONS
Notes (1) Some of the new functions cannnot be used depending on the indoor unit model.
(2) 70 indicates embedded portion in the wall.
(3) The receiving side power supply is DC12V (10 mA).
(4) When the energy consumption calculation is required, use SC-SL4-BE.
(5) The life of LCD backlight is around 80,000 hours.
(6) Durability of touch panel is around 10 million times.
(7) On the “Function Setting” screen, it is possible to change the batch error output to normally Open and Close at error occurrence.
(8) The energy consumption calculated by this unit does not conform to OIML, and there are no guarantees concerning the results of the calulations.
This unit calculates only energy consumption distribution (electric power).
You need to calulate the air-conditioning rates.
(9) For the editing software and contents, refer to the Technical manual ’10
SC-T-152 or -153.
Description
Model name
Applicable model
Ambient temperature at operation
Power supply
Power consumption
External dimensions (H×W×D)
Net weight
LCD touch panel
(5)
(6)
Max. number of
connectable indoor units
Super Link compatible indoor unit
(1)
0 ~ 40˚C
1 phase 100 V, 200 ~ 240 V 50/60 Hz
9W
172mm×250mm×(23+70)mm
(2)
2kg
Color LCD, 9 inch wide
New SL: Max. 128 units×1 network,
Previous SL: Max. 48 units3 networks = Max. 144 units
New SL: 1 network, Previous SL: 3 networks
8 points, pulse width 100 ms or more
1 point, Non-voltage contact point “a” input, Continuous input
(Open /Close: Stop & Center)
Input
Output
Super Link input
Gas, power pulse input
(3)
Emergency stop signal input
(3)
Demand signal input
(3)
Operation output
Error output
CENTRAL CONTROL SC-SL4-AE
SC-SL4-AE
CENTRAL CONTROL SC-SL4-BE
SC-SL4-BE
Selection of language
2 point, Non-voltage contact point “a” input, Continuous input
(Open
/
Close Demand control)
1 point, Maximum rated current 40 mA. DC24V
All indoor units at stop: Open, If there is any unit operating: Close
1 point, Maximum rated current 40 mA. DC24V
All indoor units at normal: Close, If there is any error unit: open
(7)
English or Spanish can be selected as the default language.
If a language is edited/registered beforehand,
one of major European languages can be used on the display.
(9)
Fig.1 Appearance
Page view 2
1 2 3 4 5 6 7 8 ... 36 37