’13 • SC-T-192
3. CONTROL SELECTION SETTING
It is possible to change the setting as follows by setting on the “Function Setting”
Item Description
Backlight timeout time
Brightness
SL mode
Auto mode setting
Remote control timer setting
Folder name specification
Error output
(Fan)Powerful Mode
Auto Fan Speed
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Time from the last operation on the touch panel until the monitor backlight turns
OFF can be selected.
It is possible to invalid timer setting of the remote control.
“Powerful” mode can be set or not.
It is possible to specify the folder to transfer the calulated data to USB memory.
(SL4-BE only)
It is possible to choose “Closed” or “Open” status for error output during normal
operation of air conditioning unit.
It is possible to invalid permission/prohibition setting of the remote control func-
tion can be prohibited from SL4-AE (SL4-BE).
If this item be set “Invalid”, it can not be set remote control function permis-
sion/prohibition setting and can be set “ALL Lock” (Center) or “ALL unlock”
(Center & Remote) only.
Remote control Permission/
Prohibition setting
Remote control function
Permission/prohibition setting
In case of managing with two or more central control, it is possible to prohibit the
validity or invalidity of the manual remote control operation from SL4-AE (SL4-
BE) so as not to contradict the remote control operation permission/prohibition
setting. At prohibition setting, remote control function permission/prohibition set-
ting is also invalid.
Brightness for the monitor backlight can be selected.
Sets new or previous Super Link.
“ Auto” mode can be set or not.
This setting is used to valid/invalid the Auto Mode.
Temp. Indication
This selects Fahrenheit or Celsius for the temperature display.
Upper/Lower Temperature Limit Setting
Used to set the lower temperature limit to 16-18 and the higher temperature limit
to 30-35 for the cooling mode and the lower temperature limit to 10-18 for
the heating mode.
Security Lock Setting
Used to valid/invalid the Security Lock. The password is required to turn on the
backlight which is turned off when the Security Lock is valid.
Language Setting
Used to select the display language. Also, users can import language data from a
USB memory device.
Demand & Emergency Stop Setting
You can invalid or valid schedule adjustment at the release of emergency stop or
demand operation, and valid or invalid running of the schedule during the demand
operation
Fig.2 Display example1 Fig.3 Display example2