4 - 3 Timer operation
A weekly schedule setting can be specified for each group.
Possible to set on the timer the schedule to prohibit operation of the local remote controller in addition to ON/OFF
schedule.
NOTE:
Always set to current time on the current time setting screen when the schedule setting is performed.
Refer to section "4-5 Current time setting".
To perform a scheduled operation, make the settings that are explained under items (1) (p.20), (2)
and (3) (p.21), and set the Timer mode switch on the OPERATION SETTINGS screen to ON.
Refer to section "4-2 Operation setting".
When browser monitoring, or schedule setting from central monitoring PC, was performed, the timer
screen of this function cannot be used.
When the "Annual/Weekly Schedule" is used, the "Timer" menu will not appear on the menu screen.
When an external input signal that corresponds to "Emergency Stop" or "Level Run/Stop" is being
input, timer operation will not be performed.
<Schedule setting function summary>
1 The ON and OFF (PROHIBITION and PERMISSION) times can set in 10-minute units.
2 The daily operation schedule can include up to three ON (PROHIBITION) time settings and three OFF
(PERMISSION) time settings.
3 Three types (P1-P3) of daily ON/OFF pattern and one type (P4) of prohibition/permission pattern* are available
respectively, each of which can be set every to each group.
* "Prohibition/Permission" setting can only be made collectively for all applicable items; it cannot be set individually for each item.
Week day which is not set in timer pattern is displayed with (-).
In addition, it is also possible to set the schedule which has combined P1-P3 and P4 together.
( / / ) In this case, both of ON/OFF pattern and prohibition/permission pattern are daily executed.
Any one of these options may be selected for each separate day of the week.
4 The schedule patterns can be copied easy to other group by the memory and memory read functions because
the schedule contents can be recorded in the memory.
5 The setting temperature or set-back value setting can also be supported during timer operation.
<Shifting to the schedule setting screen>
Press the
3
switch to select
"3 SCHEDULE SETTING".
Press the
BACK
SCREEN
switch to go back to the
user operation menu screen.
Press the
switch to move the cursor position
to P1 (or P2 or P3 or ).
(The "P1" indication blinking.)
And press the
ENTER
switch to the
P1 (Pattern 1) Schedule pattern
setting screen.
User operation menu
Press the
BACK
SCREEN
switch.
Schedule pattern (P1~P3, ) setting
can be performed.
Schedule pattern setting screen
The schedule contents of each group
can be monitor.
Weekly schedule pattern setting can
be performed.
Weekly schedule setting screen