6. Electrical work
Mode
Power failure automatic recovery
Indoor temperature detecting
LOSSNAY connectivity
Power voltage
Settings
Not available
Available *1
Indoor unit operating average
Set by indoor unit’s remote controller
Remote controller’s internal sensor
Not Supported
Supported (indoor unit is not equipped with outdoor-air intake)
Supported (indoor unit is equipped with outdoor-air intake)
240 V
220 V, 230 V
Mode no. Setting no.
Initial setting
setting
01
1
2
1
02 2
3
1
03 2
3
04
1
2
Mode
Filter sign
Fan speed
No. of air outlets
Installed options (high-performance fi lter)
Up/down vane setting
Settings
100Hr
2500Hr
No fi lter sign indicator
Silent
Standard
High ceiling
4 directions
3 directions
2 directions
Not supported
Supported
Equipped with vanes (vanes angle setup
3
)
Equipped with vanes (vanes angle setup
1
)
Equipped with vanes (vanes angle setup
2
)
Mode no. Setting no.
Initial setting
setting
1
07 2
3
1
08 2
3
1
09 2
3
10
1
2
1
11 2
3
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
6.3.3 How to set the xed up/down air direction (Only for wired remote
controller and PUHZ-RP/P, PU(H)-P application)
Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to
each air conditioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the right.)
"Up/Down air direction" is the direction (angle) to fi x.
• Only the particular outlet can be fixed to certain direction with the
procedures below. Once fi xed, only the set outlet is fi xed every time air
conditioner is turned on. (Other outlets follow UP/DOWN air direction
setting of the remote controller.)
Horizontal airflow
Downward
Fixed setting
The airflow direction of
this outlet is fixed
in particular direction.
Remote controller setting
The airflow direction of
this outlet is controlled by
the airflow direction setting of
remote contoller.
When it is cold because of direct airflow,
the airflow direction can be fixed
horizontally to avoid direct airflow.
MITSUBISHI
ELECTRIC
label
Outlet No.4
Outlet No.2
Outlet No.3
Outlet No.1
Note: "0" indicates all outlets.
Reset 1
horizontal
2345
Function table
Select unit number 00
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
RG79D251K01_EN_0227.indd 11RG79D251K01_EN_0227.indd 11 28/02/2007 09:48:5628/02/2007 09:48:56