Mitsubishi Montero 1987 Service Manual Page 93

  • Download
  • Add to my manuals
  • Print
  • Page
    / 284
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 92
CHARGING SYSTEM
-Specifications
SPECIFICATIONS
GENERAL SPECIFICATIONS
ALTERNATOR
NOOEB-B
Type
Model No.
Part No.
Rated output
VIA
Voltage regulator
Items
Specifications
~--
Battery voltage sensing
A2T03477
MD1 10318
12150
Electronic built-in type
BAlTERY
Items
Type
1
Ampere hours (5 HR) Ah
Cranking rating [at - 178°C (O”F)]
A
Reserve capacity
min.
Specifications
55824R (S)-MF
36
420
75
NOTES
1. CRANKING RATING is the current a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2 or
greater at a specified temperature.
2. RESERVE CAPACITY RATING is the amount of time a battery can deliver 25 A and maintain a minimum terminal
voltage of 10.5 at 26.7”C (80°F).
SERVICE SPECIFICATIONS
NOBEC-
Items
Standard values
Regulated voltage V
Ambient temp. at voltage regulator
- 20°C ( - 4°F)
20°C (68°F)
60°C (140°F)
80°C (176°F)
Slip ring O.D. mm (in.)
Field coil resistance R
Limit
Output current A
Slip ring O.D. mm (in.)
14.2-15.4
13.9-14.9
13.4-14.6
13.1-14.5
23 (.906)
3.1
Min. 35
22.2 (.874)
Specifications
[ STB Revision
Page view 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 283 284

Comments to this Manuals