CHARGING SYSTEM
-Troubleshooting
8-75
TROUBLESHOOTING
NOBEH-
Symptom Probable cause
Remedy
Reference
we
Charging warning in- Fuse blown
dicator does not light
with ignition switch
Light burned out
“ON” and engine off.
1
1 Wiring connection loose
Check fuses
Replace light
Tighten loose connections
8-70
-
-
Charging warning in-
dicator does not go
out with engine
running
(Battery requires fre-
quent recharging)
L
t
Run-down battery
c
Electronic voltage regulator faulty
Drive belt loose or worn
Battery cables loose, corroded or worn
Fuse blown
Fusible link blown
Electronic voltage regulator or alternator
faulty
Wiring faulty
Drive belt loose or worn
Wiring connection loose or open circuit
Fusible link blown
Replace voltage regulator
Adjust tension or replace drive
belt
Repair or replace cables
Check fuses
Replace fusible link
Test alternator
Repair wiring
Adjust tension or replace drive
belt
Tighten loose connection or
repair wiring
Replace fusible link
8-79
Refer to
GROUPS.
8-8 1
8-70
8-69
8-77
8-79
-
Refer to
GROUP 9.
-
8-69
Poor grounding 1 Repair
I-
I
I I
Electronic voltage regulator or alternator
faulty
Test alternator 8-77
8-79
Overcharge
Decrease in life of battery
Replace battery
8-81
I
Electronic voltage regulator faulty Replace voltage regulator 8-79