  • Rated. / 5. Based on customer reviews
Page view 12
1313
*1 Nominal cooling conditions
Note :
Indoor :
Outdoor :
Pipe length :
Level difference :
27°CDB/19°CWB (81°FDB/66°FWB)
35°CDB (95°FDB)
7.5 m (24-9/16 ft)
0 m (0 ft)
*2 Nominal cooling conditions
27°CDB/19.5°CWB (81°FDB/67°FWB)
35°CDB (95°FDB)
5 m (16-3/8 ft)
0 m (0 ft)
*3 Nominal heating conditions
Unit converter
20°CDB (68°FDB)
7°CDB/6°CWB (45°FDB/43°FWB)
7.5 m (24-9/16 ft)
0 m (0 ft)
* Due to continuing improvement, above specification may be subject to change without notice.
* Nominal conditions *1, *3 are subject to JIS B8615-1.
kcal/h = kW × 860
Btu/h = kW × 3,412
cfm = m
3
/min × 35.31
lb = kg/0.4536
*Above specification data is
subject to rounding variation.
Service ref.
Power source
Cooling capacity
(Nominal)
Heating capacity
(Nominal )
External finish
External dimension H x W x D
Net weight
Heat exchanger
Fan
Noise level (Low-Mid2-Mid1-High)
(measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Diameter of
refrigerant pipe
Field drain pipe size
Standard
attachment
Remark
Power input
Current input
Power input
Current input
Type x Quantity
External
static press.
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid2-Mid1-High)
Liquid
Gas
Document
Accessory
Optional parts
External LEV Box
Installation
kW
kcal/h
Btu/h
kcal/h
kW
A
kW
kcal/h
Btu/h
kW
A
mm
in.
kg (lb)
Pa
mmH
2O
kW
m
3
/min
L/s
cfm
dB <A>
mm (in.)
mm (in.)
mm (in.)
*1
*1
*1
*2
*3
*3
*3
(R410A)
(R410A)
Installation Manual, Instruction Book
1-phase 220-240V 50Hz, 1-phase 220V 60Hz
Cross fin (Aluminum fin and copper tube)
1-phase induction motor
Direct-driven by motor
Polyethylene sheet
PP honeycomb
Fuse
LEV
R410A CITY
MULTI
PKFY-P20VBM-E
PKFY-P20VBM-ER1
PKFY-P20VBM-ER2
PKFY-P20VBM-ER3
Plastic, MUNSELL (1.0Y 9.2/0.2)
2.2
1,900
7,500
2,000
0.04
0.20
2.5
2,200
8,500
0.04
0.20
295 × 815 × 225
11-5/8"
×
32-1/8"
×
8-7/8"
10 (23)
Line flow fan × 1
0
0
0.017
4.9 - 5.2 - 5.6 - 5.9
82 - 87 - 93 - 98
173 - 184 - 198 - 208
29 - 31 - 34 - 36
PKFY-P25VBM-E
PKFY-P25VBM-ER1
PKFY-P25VBM-ER2
PKFY-P25VBM-ER3
2.8
2,400
9,600
2,500
0.04
0.20
3.2
2,800
10,900
0.04
0.20
295 × 815 × 225
11-5/8"
×
32-1/8"
×
8-7/8"
10 (23)
Line flow fan × 1
0
0
0.017
4.9 - 5.2 - 5.6 - 5.9
82 - 87 - 93 - 98
173 - 184 - 198 - 208
29 - 31 - 34 - 36
I.D. 16mm (5/8")
PAC-SG95LE-E
I.D. 16mm (5/8")
PAC-SG95LE-E
ø6.35 (ø1/4")
ø12.7 (ø1/2")
Flare
Flare
ø6.35 (ø1/4")
ø12.7 (ø1/2")
Flare
Flare
PKFY-P15VBM-E
PKFY-P15VBM-ER2
PKFY-P15VBM-ER3
1.7
1,450
5,800
1,500
0.04
0.20
1.9
1,600
6,500
0.04
0.20
295 × 815 × 225
11-5/8"
×
32-1/8"
×
8-7/8"
10 (23)
Line flow fan × 1
0
0
0.017
4.9 - 5.0 - 5.2 - 5.3
82 - 83 - 87 - 88
173 - 177 - 184 - 187
29 - 31 - 32 - 33
I.D. 16mm (5/8")
PAC-SG95LE-E
ø6.35 (ø1/4")
ø12.7 (ø1/2")
Flare
Flare
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to
the Installation Manual.
4
SPECIFICATION
4-1. SPECIFICATIONS
OCH418C
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 33 34