SPECIFICATION
3
Indoor model
Function
Power supply
Capacity
Air flow(High)
Dehumidification
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level (High)
Fan speed (High)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Outdoor model
Air flow (High)
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level(High)
Fan speed(High)
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
Thermistor RT61(at0:)
Thermistor RT63(at0:)
kW
K /h
L/h
A
A
W
A(kW)
%
A
A
"
mm
kg
dB
rpm
k"
k"
K /h
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k"
k"
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance(C.O.P)
Capacity
MCFH-24NV-
EB
Cooling
6.0
3.1
12.5-11.7
2,720-2,750
-
99-98
2.21-2.18
11.56-10.76
0.58
Heating
6.2
-
11.7-11.3
2,540-2,650
-
98-98
2.44-2.34
10.76-10.36
0.58
Single phase 220 - 240 V, 50Hz
840
25
59
0.36
RB4V36-AB
WHT-BLK 82.9 BLK-YLW 65.6
YLW-BLU 36.0 BLU- BRN 27.0
BRN-RED 13.7
1,100 650 180
26
5
48-48
1,310-1,330
3
10
10
MUCFH-24NV-
EB
2,640-2,760
NH-47VMDT
2,200
C-R 0.96 C-S 2.07
RA6V85-AA
WHT-BLK 62.7 BLK-YLW 30.2
YLW-RED 62.9
870 850 295
72
53
720-750
2
2.40
1.2 (MS32N1)
33.18
33.18
NOTE:Test conditions are based on ISO 5151
Cooling : Indoor DB27°C WB19°C Heating : Indoor DB20°C WB15°C
Outdoor DB35°C WB(24°C) Outdoor DB 7°C WB 6°C