REFRIGERANT SYSTEM DIAGRAM
8
6
Models
A: Refrigerant piping
Max.length
15m
Max. Height difference *
5m
MAX. REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE
MCFH-24NV -
EB
Refrigerant piping MAX. length : m
A
15
Piping size O.D. : mm
Gas Liquid
{15.88
wIt does not matter which unit is higher.
Models
MCFH-24NV -
EB
Outdoor unit:precharged
(up to 7m)
Refrigerant piping length (one way)
7m
0
8m 9m 10m 11m 12m 13m 14m 15m
Calculation : og=65g/mo(Refrigerant piping length minus 7m)
If pipe length exceeds 7m, additional refrigerant (R22) charge is required
ADDITIONAL REFRIGERANT CHARGE (R22 : g)
{
9.52
2,400 65 130 195 260 325 390 455 520
INDOOR UNIT
MCFH-24NV-
EB
OUTDOOR UNIT
MUCFH-24NV-
EB
Indoor
heat
exchanger
Outdoor
heat
exchanger
Distributor
Flared connection
Room temperature
thermistor
RT11
Coil temperature
thermistor
RT12
Flared connection
Check
valve
Stop valve
(with service port)
Stop valve
Strainer
Capillary tube
Capillary tube
Capillary tube
[4.0o[2.4o200
Discharge pressure
regurator open
23.5Of/F
Check
valve
Refrigerant flow in cooling
Compressor
Accumulator
Strainer
Muffler
4-way valve
Refrigerant flow in heating
Refrigerant pipe [15.88
(Option)
(with heat insulator)
Refrigerant pipe
(Option) [9.52
(with heat insulator)
[3.0o[1.6o350
[3.0o[2.0o350
OB266--1.qxp 01.4.13 10:31 AM Page 8