3.3 Terminal connection diagram (European version)
FR-S540-0.4K to 3.7K-EC (R)
Earth (Ground)
Power factor improving
DC reactor
(FR-BEL: Option)
3-phase AC
power supply
NFB
L
1
Frequency setting signals (Analog)
10 (+5V)
2
2
3
1
4 to 20mADC (+)
4 (4 to 20mADC)
Frequency
setting
potentiometer
1/2W1k
(*3)
SE
Running
Control input signals
(No voltage input allowed)
Jumper
: Remove this
jumper when FR-BEL
is connected.
Motor
IM
Earth
(Ground)
Alarm
output
U
V
W
P1
Selected
Operation status
output
5 (Common)
Open collector
output common
Current input (-)
MC
Open
collector
outputs
SINK
SOURCE
Inverter
Main circuit terminal, Control circuit input terminal,
Control circuit output terminal
0 to 5VDC
0 to 10VDC
(*2)
RS-485 Connector (*1)
AM
5
(+)
(-)
Analog signal
output
(0 to 5VDC)
Take care not to short
terminals PC-SD.
A*5
B
*5
C
*5
*5 RUN
When using the current input as
the frequency setting signal, set
"4" in any of Pr. 60 to Pr. 63
(input terminal function selection),
assign AU (current input selection)
to any of terminals RH, RM, RL and
STR, and turn on the AU signal.
PC
External transistor common
24VDC power supply
Contact input common (sink)
STF
SD
Forward rotation start
Reverse rotation start
Middle
High
Low
Multi-speed selection
Contact input common
STR
*4
RH *4
RM
*4
RL *4
L
2
L
3
Remarks
*1 Only the type with RS-485 communication function
*2 You can switch between the sink and source logic positions. For details, refer to the
instruction manual (detailed).
*3 When the setting potentiometer is used frequently, use a 2W1k
potentiometer.
*4 The terminal functions change with input terminal function selection (Pr. 60 to Pr. 63).
(Refer to page 38) (RES, RL, RM, RH, RT, AU, STOP, MRS, OH, REX, JOG, X14,
X16, (STR) signal selection)
*5 The terminal functions change with output terminal function selection (Pr. 64, Pr. 65).
(Refer to page 38) (RUN, SU, OL, FU, RY, Y12, Y13, FDN, FUP, RL, LF, ABC signal
selection)
CAUTION
To prevent a malfunction due to noise, keep the signal cables more than 10cm
(3.94inches) away from the power cables.