4.2 Using the setting dial like a potentiometer to perform
operation
POINT
Set "1" (extended function parameter valid) in Pr. 30 "extended function
display selection".
Set "1" (setting dial potentiometer mode) in Pr. 53 "frequency setting
operation selection".
Operation example Changing the frequency from 0Hz to 60Hz during operation
Choose monitor/frequency monitor.
( key)
The inverter must be in the PU operation
mode. (Press the key.)
Pr. 30 must be set to "1".
Pr. 53 must be set to "1".
1.
PU
EXT
Mode/monitor check
RUN
PU
EXT
MODE
RUN
3.
Turn the setting dial clockwise
until "60.0" appears. The flickering
frequency is the set frequency.
You need not press the key.
2.
Press the key to start the inverter.
RUN
SET
Flickers for 3s.
Display
Operation
RUN
PU
EXT
Remarks
If flickering "60.0" turns to "0.0", the Pr. 53 "frequency setting operation
selection" setting may not be "1".
Independently of whether the inverter is running or at a stop, the frequency
can be set by merely turning the dial.