Mitsubishi City Multi PMFY-P.VBM-E Specifications Page 39

  • Download
  • Add to my manuals
  • Print
  • Page
    / 69
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 38
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-50RX
5-E
LGH-50RX5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
1.2-1.25
255-286
500
139
15.3-15.8
150-155
78.0
69.0
66.5
33-34
1.0-1.0
207-228
500
139
6.6-9.2
65-90
78.0
69.0
66.5
30.5-32
0.85-0.85
175-190
390
108
4.1-6.1
40-60
81.0
71.0
68.0
26.5-28
0.4-0.4
80-95
180
50
1.0
10
86.0
78.0
77.0
19
Extra High High Low Extra Low
1.25-1.25
260-290
500
139
15.3-15.8
150-155
34-35
1.0-1.0
210-230
500
139
6.6-9.2
65-90
31-32.5
0.85-0.85
180-195
390
108
4.1-6.1
40-60
27-29
0.4-0.4
80-95
180
50
1.0
10
19
32
Under 3.0 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-65RX
5-E
LGH-65RX5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
1.7-1.8
350-380
650
181
11.2-12.2
110-120
77.0
68.5
66.0
34-34.5
1.5-1.5
308-322
650
181
6.1-8.2
60-80
77.0
68.5
66.0
32-33
1.2-1.2
248-265
520
144
4.1-5.1
40-50
80.0
70.5
68.5
28.5-31.5
0.6-0.6
120-140
265
74
0.8
8
86.0
78.0
77.0
22
Extra High High Low Extra Low
1.7-1.8
350-385
650
181
11.2-12.2
110-120
34.5-35
1.5-1.5
310-335
650
181
6.1-8.2
60-80
32.5-33.5
1.2-1.2
250-265
520
144
4.1-5.1
40-50
28.5-30.5
0.6-0.6
120-140
265
74
0.8
8
22-22.5
40
Under 4.4 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-80RX
5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
1.75-1.75
380-415
800
222
14.8-15.3
145-150
79.0
71.0
70.0
33.5-34.5
1.6-1.6
345-370
800
222
10.7-12.2
105-120
79.0
71.0
70.0
32-33
1.45-1.45
315-340
700
194
8.2-9.7
80-95
80.5
72.5
71.5
30-31
0.60-0.65
125-145
355
99
2
20
87.5
79.5
79.5
22
Extra High High Low Extra Low
1.75-1.75
380-415
800
222
14.8-15.3
145-150
34.5-35.5
1.6-1.6
345-370
800
222
10.7-12.2
105-120
33-34
1.45-1.45
315-340
700
194
8.2-9.7
80-95
31-32
0.60-0.65
120-145
355
99
2
20
22
53
Under 3.8 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 16 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
LGH-80RX5-E
Page76
LOSSNAY
Model line up
Specification
LGH-15RX5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
0.44-0.46
96-110
150
42
10.2-10.7
100-105
82.0
75.0
73.0
27.5-28
0.37-0.38
80-90
150
42
6.6-7.1
65-70
82.0
75.0
73.0
26.5-27
0.25-0.25
53-59
110
31
3.6-4.1
35-40
84.0
77.5
76.5
22-23.5
0.14-0.15
30-35
70
19
1.4
14
85.5
81.0
81.0
18
Extra High High Low Extra Low
0.45-0.46
97-110
150
42
10.2-10.7
100-105
28.5-29
0.37-0.38
81-91
150
42
6.6-7.1
65-70
27-28
0.25-0.26
54-61
110
31
3.6-4.1
35-40
23-24
0.14-0.15
30-35
70
19
1.4
14
18-19
20
Under 0.8 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 6 dB greater than the indicated value. (at High Fan speed)
50Hz / Single phase 220-240V
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-25RX
5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
0.52-0.55
113-129
250
69
8.2-8.7
80-85
79.0
69.5
68.0
26-27
0.47-0.48
102-114
250
69
5.1-6.1
50-60
79.0
69.5
68.0
25-26
0.26-0.27
56-62
155
43
2-2.5
20-25
81.5
74.0
72.5
20-21.5
0.17-0.18
36-42
105
29
0.9
9
83.5
77.5
76.0
18-19
Extra High High Low Extra Low
0.53-0.55
115-131
250
69
8.2-8.7
80-85
26.5-27.5
0.47-0.48
103-115
250
69
5.1-6.1
50-60
25.5-26.5
0.26-0.27
56-63
155
43
2-2.5
20-25
20.5-22
0.17-0.18
36-42
105
29
0.9
9
18-19
20
Under 0.9 A Less
*The Air outlets noise (45 angle,1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
LGH-35RX
5-E
LGH-35RX5-E
LOSSNAY ventilation By-pass ventilation
Extra High High Low Extra Low
0.92-0.92
195-212
350
97
15.8-16.3
155-160
80.0
71.5
71.0
32-32
0.74-0.74
160-169
350
97
7.6-8.2
75-80
80.0
71.5
71.0
28.5-29.5
0.5-0.51
105-116
210
58
2.5-3.1
25-30
85.0
76.5
75.5
21.5-23
0.28-0.3
58-69
115
32
0.9
9
88.0
81.5
81.0
18
Extra High High Low Extra Low
0.93-0.94
197-217
350
97
15.8-16.3
155-160
32.5-32.5
0.77-0.77
164-173
350
97
7.6-8.2
75-80
29.5-30.5
0.51-0.52
105-116
210
58
2.5-3.1
25-30
21.5-24
0.28-0.3
58-69
115
32
0.9
9
18
29
Under 2.4 A Less
*The Air outlets noise (45 angle, 1.5 meters in front of the unit) is about 10 dB greater than the indicated value. (at High Fan speed)
Frequency / Power source
50Hz / Single phase 220-240V
LGH-25RX5-E
LGH-15RX5-E
Frequency / Power source
Ventilation mode
Fan speed
Current
(
A
)
Power consumption
(
W
)
Air volume
Model
External static pressure
Temperature exchange efficiency
(
%
)
Enthalpy exchange efficiency
(
%
)
Noise
(
dB
)
(
Measured at 1.5m under the center
of panel in an anechoeic chamber)
Weight
(
kg
)
Starting current
(
m
3
/h
)
(
L/s
)
(
mmH
2O
)
(
Pa
)
Heating
Cooling
Page75
Indoor unit
Page view 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 68 69

Comments to this Manuals