Mitsubishi PU-5TJSA Service Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
17
WIRING DIAGRAM
6
SWC
SWA
OP
STD
1
2
3
CNP
D.U.M
31
X1
X1
CN120
LD9
LD6
SW4
LD24
SW8
LD23
LD22
LD21
LD20
LD19
LD18
LD17
LD16
LD15
LD14
LD13
LD12
LD11
LD10
LD5
LD4
LD3
LD1
LD7
SW7
SW6
SW5
SW3
LD8
SW2
SW1
12
fig:*3
Remote control transmissing wire 12VDC with 12 core connector
112
MV
66
CN2
TIMER
CN70
WIRELESS
SW1
SW1
Service Ref.
Service Ref. 3GJA
12.5GJA12GJA1
ON
OFF
ON
OFF
1234567812345678 12345678
ON
OFF
ON
OFF
SW2
12345
TWIN-1
CN2A
TWIN-2
CN2B
OFF
ON
SW3
123
L
N
INDOOR UNIT
TB2
REMOTE CONTROLLER
OUTDOOR UNIT
12
BLK
BLK
RT2
ORN
POWER SUPPLY
(1 PHASE)
AC220-240V 50Hz
AC220V 60Hz
R.B
2
TO OUTDOOR UNIT
CONNECTING WIRES
DC12V
1
TB4
YLW
RT1
12345678
14.7VAC
11.8VAC
13
TRANS
CNT
YLW
WHT
220V
230V
240V
RED
T
YLW
ORN
VANE
6
CN6V
1
5
12
GRN/YLW
X4
MF
CN120
TO.RC OUTDOOR
CN30
123
L.TEST
CN28
CN20
PIPE
CN21
12
CN51
MULTIPLE
1234
DRAIN
CN50
INTAKE
SW1
123 645
JR
X4
135
C
WHT
BLK
RED
I.B
FAN1
ZNR
F2 F1
432113
POWER TRANS
CND CN4T
BRN
BRN
RED
RED
BLU
RED
4GJSA1
ON
OFF
12345678
5GJSA1
ON
OFF
12345678
6GJSA1
ON
OFF
12345678
[Emergemcy operation procedure]
(2) Turn on outdoor unit side circuit breaker, then indoor unit side circuit breaker in this order.
(3) During emergency operation, indoor fan runs at high speed but automatic vane remains stop.
(4) If vane closed, open the vane by hand slowly.
(5) Thermostat will not function.
(6) Emergency cooling should be limited to 10 hours maximum (The Indoor unit heat exchanger may freeze).
(7) If the ,microcomputer doctor detects the abnomality of the drain-up machine during cool mode. do not execute emergency operation (It causes drain overflow).
3. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
4. Symbols used in wiring diagram above are. : Connector , : Terminal block
5. Emergency operation
If remote controller or microcomputer fails but there is no other trouble,. emergency operation is possible by setting dip switch (SW3<I.B>) on the indoor controller board.
[Check items]
(1)Compressor and fan.
(2)Check the abnomality using self diagnostic function. When the result of self diagnosis indicates protective device such as freeze protection, emergency operation is not possible
unless the cause is removed.
(3)Emergency operation will be continuous operation mode due to power ON/OFF (ON/OFF with remote controller is not possible).
[Emergency operation procedure]
(1)Set the dip switch(SW3<I.B>) on the indoor controller board to
1 2 onand 3 off for cooling.
NOTES :
1. Since the indoor fan motor (MF) is connected with 220V power, using 230, 240V power will require a setting change of the dip switch (SW1<I.B>) on the indoor controller board
as shown in fig :
w
1.
2. Since the indoor transformer (T) is connected with 220V power, if 230, 240V power used. Change the wiring connection showing fig : W2.
240V
230V
240 YELLOW
230 ORANGE
220 RED
SYMBOL
C
CN120<I.B>
CN2<I.B>
CN2A<I.B>
CN2B<I.B>
CNP<I.B>
CN28<I.B>
CN50<I.B>
CN51<I.B>
CN120<R.B>
F1,2<I.B>
CN70<I.B>
I.B
NAME
FAN MOTOR CAPACITOR
REMOTE CONTROLLER TRANS-
MISSION WIRE CONNECTOR
TIMER ADAPTOR CONNECTOR
TRANSMISSION WIRE No.1
CONNECTOR
TRANSMISSION WIRE No.2
CONNECTOR
DRAIN-UP MACHINE CONNECTOR
TIME SHORTENING CONNECTOR
DRAIN SENSOR CONNECTOR
MULTIPLE CONNECTOR
REMOTE CONTROLLER TRANS-
MISSION WIRE CONNECTOR
FUSE (6.3A 250V)
WIRELESS REMOTE CONT-
ROLLER CONNECTOR
INDOOR CONTROLLER BOARD
SYMBOL
LD1<R.B>
LD3<R.B>
LD4<R.B>
LD5<R.B>
LD6<R.B>
LD7<R.B>
LD8<R.B>
LD9<R.B>
LD10<R.B>
LD11<R.B>
LD12<R.B>
LD13-24<R.B>
MF
MV
SWA<I.B>
JR<I.B>
NAME
RUN INDICATOR LED
COOLING INDICATOR LED
FAN MODE INDICATOR LED
FAN HIGH INDICATOR LED
LOUVER RUN INDICATOR LED
INDICATOR MODE TEMPERATURE LED
INDICATOR MODE TIMER LED
DRY INDICATOR LED
FAN LOW INDICATOR LED
OFF TIMER INDICATOR LED
ON TIMER INDICATOR LED
TEMPERATURE / TIMER RE-
MAINING TIME INDICATOR LED
FAN MOTOR
VANE MOTOR
HIGH CELING TYPE SWITCH
FUNCTION SELECTOR
JUMPER RESISTORS
SYMBOL
SWC<I.B>
SW1<I.B>
SW2<I.B>
SW3<I.B>
SW1<R.B>
SW2<R.B>
SW3<R.B>
SW4<R.B>
SW5<R.B>
SW6<R.B>
SW7<R.B>
SW8<R.B>
R.B
T
TB2
NAME
OPTION SWITCH
FUNCTION SWITCH
UNIT SWITCH
EMERGENCY OPERATION SWITCH
ON / OFF SWITCH
OPERATION MODE SWITCH
FAN HIGH/LOW SWITCH
LOUVER ON / OFF SWITCH
INDICATOR SWITCH
TEMPERATURE / TIMER
SETTING UP SWITCH
TEMPERATURE / TIMER
SETTING DOWN SWITCH
TIMER CONTINUOUS ON / OFF SWITCH
REMOTE CONTROLLER BOARD
TRANSFOMER
POWER SUPPLY TERMINAL BLOCK
SYMBOL
TB4
RT1
RT2
X1<I.B>
X4<I.B>
ZNR
DP
DS
W/B
CNB(W.B)
LED1(W.B)
SW2(W.B)
RU(W.B)
NAME
INDOOR / OUTDOOR CONNECT-
ING WIRE TERMINAL BLOCK
ROOM TEMPERATURE THERMISTOR
(0 /15k ,25 /5.4k DETECT)
INDOOR COIL THERMISTOR
(0 /15k ,25 /5.4k DETECT)
DRAIN-UP MACHINE RELAY
FAN MOTOR RELAY
VARISTOR
OPTION DRAIN-UP MACHINE
OPTION DRAIN SENSOR
OPTION WIRELESS REMOTE
CONTROLLER BOARD
INDOOR BOARD CONNECTOR
RUN INDICATOR LED
COOL OPERATION SWITCH
BEAM RECIEVE UNIT
fig : w1
Indoor fan motor (MF) for 230, 240V.
fig : w2
When power supply is
12345678
SW1
ON
OFF
12345678
ON
OFF
PC-2GJA1 / PC-2.5GJA1 / PC-3GJA1 / PC-4GJSA1 / PC-5GJSA1 / PC-6GJSA1