8 OPERATION FLOW-CHART
Models : PC-GJA
1. Main operation
1
Start
POWER SUPPLY
Live
ON/OFF
button ON
TIMER MODE
button ON
During
operation
AUTO STOP lamp ON AUTO START lamp ON
Auto start timer
1 12Hr up/ press
12 1Hr down/ press
Abnormal
operation mode
MODE SELECT
button
EMERGENCY
ALL STOP
STOP
STOP
Self-diagnostic function
Indicate & Memory
Protection device
Self hold
Protection device
Self hold reset
COOL OPERATION
DRY OPERATION
POWER lamp ON
NO
NO
NO
NO
NO
NO
NO
DRY
COOL
YES
YES
YES YES
YES
YES
YES
<w1>
<w3>
<w2>
<w5>
<w4>
Auto stop timer
1 12Hr up/ press
12 1Hr down/ press
Set time -
Elapsed time=0
Set time -
Elapsed time=0
w1 Refer to page 26 for timer mode details.
w2 The unit starts operation by pressing the ON / OFF switch when unit is OFF.
w3 The factors which cause "abnormal operation mode" are as follows.
Outdoor unit abnormal operation.
Fault of room temperature thermistor (RT1).
Fault of indoor coil thermistor (RT2).
Indoor coil frost protection mode.
Drain water overflow prevention mode.
Refer to page 28 for abnormal operation mode details.
w4 The compressor will not start for 3 minutes after the stop.