6 DATA
6-1. REFILLING REFRIGERANT CHARGE (R410A : kg)
6-2. COMPRESSOR TECHNICAL DATA
Piping length (one way)
10m
20m
30m
40m
50m
Initial
charged
2.1
2.1
3.1
3.1
4.6
4.6
4.6
2.3
2.3
3.3
3.3
4.8
4.8
4.8
2.5
2.5
3.5
3.5
5.0
5.0
5.0
2.7
2.7
4.1
4.1
5.6
5.6
5.6
2.9
2.9
4.7
4.7
6.2
6.2
6.2
60m
6.8
6.8
6.8
75m
7.4
7.4
7.4
2.5
2.5
3.5
3.5
5.0
5.0
5.0
Service Ref.
PUHZ-RP35VHA2(1)
PUHZ-RP35VHA3
PUHZ-RP50VHA2
(1)
PUHZ-RP50VHA3
PUHZ-RP60VHA2
(1)
PUHZ-RP60VHA3
PUHZ-RP71VHA2
(1)
PUHZ-RP71VHA3
PUHZ-RP100VHA2
(1)
PUHZ-RP100VHA
3
PUHZ-RP100YHA2
(1)
PUHZ-RP100YHA
3
PUHZ-RP125VHA2
PUHZ-RP125VHA2
1
PUHZ-RP125YHA2
PUHZ-RP125YHA2
1
PUHZ-RP140VHA2
PUHZ-RP140VHA2
1
PUHZ-RP140YHA2
PUHZ-RP140YHA2
1
U-V
U-W
W-V
Serice Ref.
Compressor model
Winding
Resistance
( " )
ANV33FDDMT
(at 20°C)
0.266
0.266
0.266
SNB130FLBH
0.300 ~ 0.340
0.300 ~ 0.340
0.300 ~ 0.340
PUHZ-RP100VHA2
ANV33FDBMT
1.064
1.064
1.064
ANB33FDFMTANB33FCKMT
0.302
0.302
0.302
0.188
0.188
0.188
PUHZ-RP100YHA2
PUHZ-RP35/50VHA2
PUHZ-RP35/50VHA2
1
TNB220FMBH
0.865 ~ 0.895
0.865 ~ 0.895
0.865 ~ 0.895
PUHZ-RP60/71VHA2
PUHZ-RP60/71VHA2
1
PUHZ-RP125/140YHA2
PUHZ-RP125/140VHA2
U-V
U-W
W-V
Serice Ref.
Compressor model
Winding
Resistance
( " )
ANV33FDJMT
(at 20°C)
0.266
0.266
0.266
PUHZ-RP100VHA21
ANV33FDGMT
1.064
1.064
1.064
ANB33FDLMTANB33FCNMT
0.302
0.302
0.302
0.302
0.302
0.302
PUHZ-RP100YHA21
PUHZ-RP125/140YHA21
PUHZ-RP100YHA3
PUHZ-RP125/140VHA2
1
PUHZ-RP100VHA3
U-V
U-W
W-V
Serice Ref.
Compressor model
Winding
Resistance
( " )
SNB130FGCH
(at 20°C)
0.64
0.64
0.64
PUHZ-RP35/50VHA3
SNB172FDGM1
0.72
0.72
0.72
PUHZ-RP60/71VHA3
Longer pipe than 30m, additional charge is
required.