Mitsubishi PUHZ-RP60VHA Service Manual Page 146

  • Download
  • Add to my manuals
  • Print
  • Page
    / 178
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 145
146
OPERATING PROCEDURE
PHOTOS
Photo 10
5. Removing the thermistor <Outdoor 2-phase pipe> (TH6)
(1) Remove the service panel. (See figure 1.)
(2) Remove the top panel. (See figure 1.)
(3) Disconnect the connector TH7/6 (red), on the
controller circuit board in the electrical parts box.
(4) Loosen the 2 wire clamps on top of the electrical parts box.
(5) Pull out the thermistor <Outdoor 2-phase pipe> (TH6)
from the sensor holder.
Note: In case of replacing thermistor <Outdoor 2-phase
pipe> (TH6), replace it together with thermistor
<Outdoor> (TH7) since they are combined together.
Refer to No.6 below to remove thermistor <Outdoor>.
6. Removing the thermistor <Outdoor> (TH7)
(1) Remove the service panel. (See figure 1.)
(2) Remove the top panel. (See figure 1.)
(3) Disconnect the connector TH7/6(red) on the controller
circuit board in the electrical parts box.
(4) Loosen the 2 wire clamps on top of the electrical parts box.
(See photo 10.)
(5) Pull out the thermistor <Outdoor> (TH7) from the sensor
holder.
Note: In case of replacing thermistor <Outdoor> (TH7),
replace it together with thermistor <Outdoor 2-
phase pipe> (TH6), since they are combined together.
Refer to No.5 above to remove thermistor <Outdoor
2-phase pipe>.
Photo 12
Clamp
Thermistor
<Outdoor 2-phase pipe>(TH6)
7. Removing the thermistor <Outdoor pipe> (TH3) (TH33)
and thermistor <Discharge> (TH4)
(1) Remove the service panel. (See figure 1.)
(2) Disconnect the connectors, TH3 (white) and TH4 (white),
TH33 (yellow) on the controller circuit board in the
electrical parts box.
(3) Loosen the clamp for the lead wire in the rear of the
electrical parts box. (See photo 4.)
(4) Pull out the thermistor <Outdoor pipe> (TH3), (TH33) and
thermistor <Discharge> (TH4) from the sensor holder.
(TH33 : See Photo 14.)
Electrical parts box
Photo 11
Lead wire of thermistor <Outdoor> (TH7)
Sensor holder
Thermistor
<Discharge>
(TH4)
Thermistor <Outdoor pipe> (TH3)
Compressor (MC)
Lead wire of thermistor <Outdoor> (TH7)
Sensor holder
PUHZ-RP100/125/140YHA21 PUHZ-RP100YHA3
PUHZ-RP100/125/140YHA2
OC374C--5.qxp 08.2.22 8:13 AM Page 146
Page view 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 177 178