Mitsubishi PUHZ-RP60VHA Service Manual Page 79

  • Download
  • Add to my manuals
  • Print
  • Page
    / 178
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 78
79
Outdoor noise filter circuit board
PUHZ-RP35VHA21 PUHZ-RP35VHA3
PUHZ-RP50VHA21 PUHZ-RP50VHA3
LO, NO
Voltage of
220-240V AC is
output.
(Connect to the ACL)
CN52C
52C relay signal
(Connect to the
outdoor controller
circuit board
(CN52C))
CN5
Primary current
(Connect to the
outdoor power
circuit board
(CN5))
CNAC1, CNAC2
220-240V AC
(Connect to the
outdoor controller
circuit board
(CNAC))
EI
Connect to the earth
LI, NI
Voltage of 220-240V AC is input.
(Connect to the terminal block(TB1))
E3
Connect to the earth
E2
Connect to the earth
OC374C--3.qxp 08.2.22 8:15 AM Page 79