Mitsubishi FR-S500 Instruction Manual Page 69

  • Download
  • Add to my manuals
  • Print
  • Page
    / 191
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 68
60
Parameter Name
Factory
Setting
<EC version>
Setting
Range
Remarks
3
Base frequency 60Hz
<50Hz>
0 to 120Hz

19
Base frequency
voltage
- - -
<888>
0 to 500V,
888, - - -*1
888: 95% of power supply voltage*2
- - -: Same as power supply
voltage*3
Setting is enabled when Pr. 30 = "1".
47
Second V/F (base
frequency)
- - -
0 to
120Hz, - - -
- - -: Function invalid
Setting is enabled when Pr. 30 = "1".
*1 0 to 800V, 888, - - - for FR-S540-0.4K to 3.7K.
*2 1.9 times greater than the power supply voltage for the FR-S510W-0.1K to 0.75K.
*3 Twice greater than the power supply voltage for the FR-S510W-0.1K to 0.75K.
<Setting>
In Pr. 3 and Pr. 47, set the base frequency (motor's rated frequency).
Use the RT signal to switch between these two different base frequencies.
(Turn on the RT signal to make Pr. 47 valid.) (*)
When running the standard motor, generally set the "base frequency" to the rated
frequency of the motor. When running the motor using commercial power supply-
inverter switch-over operation, set the base frequency to the same value as the
power supply frequency.
When the frequency given on the motor's rating plate is only "50Hz", always set the
"base frequency" to "50Hz". Leaving the base frequency unchanged from "60Hz"
may make the voltage too low and the torque insufficient, resulting in an overload
trip. Special care must be taken when "1" is set in Pr. 14 "load pattern selection".
Set the base voltage (e.g. rated voltage of motor) in Pr. 19.
CAUTION
1. Set 60Hz in Pr. 3 "base frequency" when using a Mitsubishi constant-torque motor.
2. When automatic torque boost is selected, Pr. 47 is invalid. When automatic
torque boost is selected, setting "- - -" or "888" in Pr. 19 uses the rated output
voltage.
REMARKS
* The RT signal serves as the second function selection signal and makes the
other second functions valid.
Related parameters
When rated motor frequency is "50Hz"
Pr. 14 "load pattern selection" (refer to page 66)
RT signal (second function "Pr. 47") setting
Pr. 60 to Pr. 63 (input terminal function
selection) (refer to page 88)
Motor setting
Pr. 71 "applied motor" (refer to page 93)
Automatic torque boost selection
Pr. 98 "automatic torque boost selection (motor capacity)"
(refer to page 109)
Page view 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 190 191

Comments to this Manuals

No comments