39
-20 -10 0 10 20 30 40
0
10
20
30
40
50
60
70
80
90
100
Temperature (°C)
Defrost thermistor (RT61)
Temperature (°C)
Discharge temperature thermistor (RT62)
0 102030405060708090100110120
0
100
200
300
400
500
600
700
0 1020304050607080
0
20
40
60
80
100
120
140
160
180
200
Temperature (°C)
Fin temperature thermistor (RT64)
Resistance (kΩ)
Resistance (kΩ)
Resistance (kΩ)
1. Inverter P.C. board
MUZ-HC25VA MUZ-HC35VA MUZ-HC35VAB
11-6. TEST POINT DIAGRAM AND VOLTAGE
Back side of unit
Output to drive
outdoor fan motor
(CN771)
Fin temperature
thermistor/RT64
(CN642)
Discharge temperature
thermistor/RT62
(CN641)
Defrost thermistor/RT61
(CN641)
230V AC
DB61
Jumper wire for change
in defrost setting (JS)
Front side of unit
DB61
280 V ~ 370 V
DC
Smoothing capacitor
(C62)
Smoothing capacitor
(C61)
Output to
drive
compressor
(LDW,
LDV,
LDU)
LED monitor
lamp
R.V.coil
(CN721)
(+)
(-)
Fuse
(F701)
Fuse
(F801)
Jumper wire for pre-heat
control setting (JK)
Varistor
(NR61)
Varistor
(NR63)
Varistor
(NR62)
LEV
(CN724)