Specifications
Specifications
Rated Power Supply: AC 100-240V 50/60Hz
Rated Input: 1.00-0.50A (100-240V)
Color System: PAL-type color system.
Operating Temperature: 41°F-104°F (5°C to 40°C).
Relative Humidity: Max.80(%)
Altitude: Max.3000(m)
Dimensions: 425(Width) x 380(Depth) x 113(Height)(mm).
Weight: 7.1kg
Recording System Digital recording system with JPEG compression method.
Sampling 13.5MHz
Data Compression JPEG
Compression Unit Field
Audio Recording System PCM
Resolution 684 x 288
Recording Device 30GB HDD
Video Input: 9 Input BNC-Connector: 1.0 V(p-p), 75 ohms.
Monitor Output: S-Connector: Y-Signal: 1.0 V(p-p), 75 ohms.
C-Signal: 0.286 V(p-p), 75 ohms.
BNC-Connector: 1.0 V(p-p), 75 ohms.
Throughout Output: 9 Output BNC-Connector: 1.0 V(p-p), 75 ohms.
Audio Input: -8 dBs, 50 kohms.
Audio Output: -8 dBs, 1 kohms.
Microphone Input: -67 dBs, 600 ohms.
Timer Program: 8programs-Daily start and stop time for one week x3set.
Memory Backup: Lasts for more than 1 month.
CONNECTORS
POWER ON Input: Terminal for power ON. LOW: POWER OFF / HIGH: POWER ON
POWER OFF Input: Terminal for power OFF. LOW: POWER OFF
ALARM IN(1-9) Input: Terminal for starting alarm recording.
CLOCK ADJ Input: Terminal for adjusting clock.
REC Input: Terminal for starting.
GND: Terminal for ground.
ALARM OUT Output: Terminal for output while alarm recording is under way.
MODE OUT Output: Terminal for indication of recording selected mode.
DC 5V OUT Output: Terminal for DC 5V OUT.
CALL OUT/CALL OUT GND: Terminal for external warning device.
Rating:
ALARM OUT / Active: “Low” Level. Max. Drive current 7mA DC.
MODE OUT Non active: Open. Max. Voltage +24V DC.
ALARM IN / CLOCK ADJ / Active: When terminals are short-circuited or “Low” Level voltage is applied.
REC Non active: Open.
CALL OUT / Active: ON. Max. Drive current 7mA DC.
CALL OUT GND Non active: Open. Max. Voltage +24V DC.
RS-232C RS-232C (D-SUB 9pin) terminal for connection with personal computer.
SCSI SCSI2 (Half pitch 50pin) terminal.
Accessories
AC power cord (for U.K / for the Continent) 2
Ferrite core 2
Cable tie 2
Accessory software 1
Cable (for the extra install hard disk drive) 2
Screw (for the extra install hard disk drive) 18
Stopper (for the extra install hard disk drive) 1
Weight and dimensions shown are approximate.
Design and specifications are subject to change without notice.
<Interface circuit inside the unit>
5V
5V
10k
22k
Input
terminal
0.047µF
GND
POWER ON/POWER OFF/
ALARM IN/REC/CLOCK ADJ
Input terminal
• Input Circuit
<Interface circuit inside the unit>
Output terminal
GND terminal
ALARM OUT/MODE OUT Output terminal
• Output Circuit
<Interface circuit inside the unit>
CALL OUT terminal
CALL OUT GND terminal
CALL OUT output terminal
• Output Circuit
Page view 75
1 2 ... 71 72 73 74 75 76 77

Comments to this Manuals

No comments