Mitsubishi City Multi PMFY-P.VBM-E Specifications Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 69
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
Specifications
Note:
PLFY-P32VBM-E PLFY-P40VBM-E PLFY-P50VBM-E PLFY-P63VBM-E
3.6
12,300
4.0
13,600
0.03
0.02
0.22
0.14
4.5
15,400
5.0
17,100
5.6
19,100
6.3
21,500
7.1
24,200
8.0
27,300
0.05
0.04
0.36
0.29
Power source
Cooling capacity
Heating capacity
Power
consumption
Current
External finish
(Munsell No.)
Dimension
H W D
Net weight
Heat exchanger
Fan
Motor
Air filter
Refrigerant
pipe diameter
Field drain pipe diameter
Sound pressure level
(Lo-Mid1-Mid2-Hi) 2 3
Type Quantity
Airflow rate
(Lo-Mid1-Mid2-Hi)
External static pressure
Type
Output
Gas
(Flare)
Liquid
(Flare)
0.04
0.03
0.29
0.22
22 (49)
Turbo fan 1
11-12-13-14 12-13-14-16
ø12.7 (ø1/2)
14-15-16-18
DC motor
ø6.35 (ø1/4)
ø9.52 (ø3/8)
O.D. 32 (1-1/4)
27-28-29-31 27-28-30-31 28-29-30-32
ø12.7 (ø1/2) / ø15.88 (ø5/8)
(Compatible)
ø6.35 (ø1/4) / ø9.52 (ø3/8)
(Compatible)
258 840 840 (10-3/16 33-8/1 33-8/1)
35 950 950 (1-3/8 37-7/16 37-7/16)
208 570 570 (8-1/4 22-1/2 22-1/2)
20 650 650 (13/16 25-5/8 25-5/8)
kW
BTU/h
kW
BTU/h
kW
kW
A
A
mm(in.)
mm(in.)
kg(lbs.)
kg(lbs.)
m
3
/min
L/s
cfm
Pa
kW
mm(in.)
mm(in.)
mm(in.)
dB(A)
1
1
1
1
2
PLFY-P80VBM-E PLFY-P100VBM-E PLFY-P125VBM-E
9.0
30,700
10.0
34,100
0.07
0.06
0.51
0.43
11.2
38,200
12.5
42,700
0.15
0.14
1.00
0.94
14.0
47,800
16.0
54,600
0.16
0.15
1.07
1.00
White (6.4Y 8.9/0.4)
Galvanized steel sheet
23 (51)
6 (13)
Cross fin (Aluminum plate fin and copper tube)
16-18-20-22
ø15.88(ø5/8)
0
0.050
0.120
PP Honeycomb
30-32-35-37
27 (60)
21-24-27-29
22-25-28-30
183-200-217-233
388-424-459-494
200-217-233-267
424-459-494-565
233-250-267-300
494-530-565-636
267-300-333-367
565-636-706-777
350-400-450-483
742-848-953-1024
367-417-467-500
777-883-989-1059
34-37-39-41 35-38-41-43
ø15.88 (ø
5/8) / ø19.05 (ø3/4)
(Compatible)
298 840 840 (11-3/4 33-1/8 33-1/8)
1-phase 220-240V 50Hz / 1-phase 200V 60Hz
Cooling
Heating
Cooling
Heating
Unit
Panel
Unit
Panel
Unit
Panel
Unit
Panel
Cooling
Heating
Cooling
Heating
1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27˚C(81˚F)DB/19˚C(66˚F)WB,Outdoor 35˚C(95˚F)DB
Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(45˚F)DB/6˚C(43˚F)WB
2 Airflow rate/Sound pressure level are in (low-middle-high) or (low-middle1-middle2-high).
3 It is measured in anechoic room at power source 230V.
PLFY-P20VCM-E PLFY-P25VCM-E PLFY-P32VCM-E PLFY-P40VCM-E
0.05
0.05
0.23
0.23
0.05
1-phase 220-240V 50Hz
Galvanized steel sheet with gray heat insulation
White (6.4Y 8.9/0.4)
15.5 (35)
3 (7)
17 (38)
3 (7)
0 (direct blow)
PP Honeycomb (long life type)
1-phase induction motor
Cross fin (Aluminum plate fin and copper tube)
Turbo fan
1
0.05
0.23
0.23
0.06
0.06
0.28
0.28
0.06
ø12.7 (ø1/2)
ø6.35 (ø1/4)
0.06
0.28
2.2
2.5
2.8
3,2
3.6
4.0
4.5
7,500
9,600
12,300 15,400
5.0
8,500 10,900
13,600 17,100
0.28
8-9-10 8-9-10
8-9-11
8-9-11
133-150-167
133-150-167
133-150-183
133-150-183
283-318-353 283-318-353 283-318-388 283-318-388
Power source
kW
Cooling capacity
1
1
1
1
kW
BTU/h
BTU/h
kW
kW
A
A
mm(in.)
mm(in.)
kg(lbs.)
kg(lbs.)
L/s
cfm
m
3
/min
Pa
kW
mm(in.)
mm(in.)
mm(in.)
dB(A)
Heating capacity
Power
consumption
Current
External finish
(Munsell No.)
Dimension
Unit
Panel
Unit
Panel
Net weight
Heat exchanger
Fan
Type Quantity
External static
pressure
Motor
Output
Type
Air filter
Refrigerant
pipe diameter
Gas(Flare)
Liquid(Flare)
Field drain pipe diameter
Sound pressure level
(Lo-Mid-Hi) 2 3
Airflow rate
2
(Lo-Mid-Hi)
0.011 0.015 0.02 0.02
28-31-35 28-31-37 29-33-38 30-34-39
O.D. 32 (1-1/4)
H W D
11.5m
360˚
Page42
Specifications
PLFY-P VBM-E
PLFY-P VCM-E
INDOOR UNIT
Ceiling cassette type
4-way airflow
The new 4-way cassette VBM offers 72 different airflow patterns, making
it ideal for applications with ceilings up to 4.2 m (13-13/16ft) in height.
Compact body to match with 2 feets
(600mm) x 2 feets (600mm) ceiling
design (VCM)
570mm
570mm
570mm
570mm
570mm
570mm
PLFY-P VBM PLFY-P VCM
Auto-fan-speed mode enables speedy and
comfortable heating during heating startup.
The Auto-fan-speed mode is added to the
usual four steps “Low, Mid1, Mid2, High.”
The Auto-fan-speed mode enables speedy
and comfortable air conditioning because the
air flow speeds up when starting, and air flow
slows down when the air conditioning
becomes stable. (PLFY-P VBM-E ONLY)
Low
High AutoMid2Mid1
* When using a wireless remote controller, initial settings are
required.
* Optional parts air outlet shutter plate (PLFY-P VBM-E
ONLY) is required for 2 or 3 way outlet selection.
*Default
*The ceiling may be smudged at a spot where the supplied
airflow is seriously disturbed.
Discharge air reaches wider area and the fan
speed is decreased by 20% thanks to the new
wide shape air outlet.
Cooling softly with Wide Air Flow
Conventional model
New model
72 patterns of airflow to accommodate
any room layout are available.
First in the industry
The number of outlet can be set to 4, 3, or 2. Flexible airflow is
available by fixing the up-down airflow direction of the outlet
with a wired remote controller (or manually).
72 airflow patterns
4-, 3-, or 2- way outlet selection*
Setting the air direction for each
outlet with wired remote controller
Down blow
Horizontal blow
Remote controller setting
Fixed
*On the commercial air
conditioners (According to the
survey by Mitsubishi Electric)
Auto-fan-speed mode of
4-way Cassette with “i-
see sensor” heats the
floor well and decreases
the temperature
difference at the top and
bottom in a room.
Preset temperature is
tended to be higher
than we need,
because heated air
rises to the ceiling.
Feeling temperature
at 20
˚C
(Bottom17
˚C
)
Feeling temperature
at 20
˚C
(Bottom 20
˚C
)
37˚C
25˚C
13˚C
37˚C
25˚C
13˚C
New 4-way Cassette PLFY-VBM controls the
temperature difference at the top and bottom in
a room by checking the floor temperature with“i-
see sensor”. Comfortable air conditioning can
be realized smoothly with “sensible temperature
control.” (Option PAC-SA1ME-E, PLFY-VBM-E
ONLY)
“i-see sensor” can be used with
ceiling cassette type 4-way airflow
unit. (Option PAC-SA1ME-E, PLFY-
VBM-E ONLY)
Prevents overcooling/overheating, and
improves comfort/energy-efficiency
Without i-see sensor: preset temperature at 23˚C
With i-see sensor+Auto fan speed: preset temperature at 20˚C
In heating
In heating
Automatic Air Speed Adjustment
Draft-less Air Distribution
Wide Air Flow
(PLFY-P VBM-E ONLY)
Controls the four fan speed modes automatically
The horizontal blow mode* newly employed
supplies airflow horizontally not bringing
cooled/warmed air directly to occupants thus
preventing discomfort sensation due to
excessive cooling or direct exposing of
occupants to the air blow.
(PLFY-P VBM-E ONLY)
Suction temperature sensor
The area that the ceiling
cassette without
“i-see sensor” can monitor.
2.7m
Suction temperature sensor
11.5m
11.5m
The area that the ceiling
cassette with
“i-see sensor” can monitor.
360˚360˚
Draft-less air distribution
can be performed
by horizontal blow.
Page41
Indoor unit
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 68 69

Comments to this Manuals

No comments