Mitsubishi PU-5TJSA Service Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
Thermal
switch
Indoor heat
exchanger
Distributor
with strainer
Flared
connection
Flexible tube
Compressor
: flow of refrigerant
Flared
connection
High
pressure
switch
(With insulator) option
Refrigerant pipe
9.52 (3/8F)
OUTDOOR UNIT
(With insulator) option
Refrigerant pipe
19.05 (3/4F)
Ball
valve
Check plug
Outdoor heat
exchanger
Charge
plug
Accumulator
INDOOR UNIT
Capillary tube
PU-5Y·TJSA (O.D. 4.0 oI.D. 2.4 –R400)
PU-6Y·TJSA (O.D. 4.0 oI.D. 2.4 –R200)
Capillary tube
PU-5Y·TJSA
(O.D. 4.0 oI.D. 2.4 –R840)o2pcs
PU-6YJSA
(O.D. 4.0 oI.D. 2.4 –R1200)o2pcs
PU-6TJSA
(O.D. 4.0 oI.D. 2.4 –R740)o2pcs
Strainer
Ball valve
(with service port)
DPR
PC-5GJSA1, 6GJSA1 / PU-5YJSA, PU-5TJSA
PU-6YJSA, PU-6TJSA
Page view 18