CHAPTER 3 INSTALLATION
3.2 Designing Conditions of Operation Box
10
3.2.2 Operation Box Heat Radiation Countermeasures
Please refer to following method for heat radiation countermeasures method.
<Hypothetical conditions>
(1) Average temperature in cabinet : 55°C
(2) Cabinet peripheral temperature : Ta 0°C~45°C
(3) Internal temperature rise value : T = T Ta (max) = 10°C
<Supplement>
(1) Refer to "3.1 General Specification" for
the heat generated by each unit.
(2) Enclosed cabinet (thin steel plate)
cooling capacity (W1) calculation
equation
W1 = U × A × T
U : 6W/m
2
× °C
... with internal circulation fan
4W/m
2
× °C
... without internal circulation fan
A : Effective heat radiation area (m
2
)
T : Internal temperature rise value
(10°C)
(Area where heat can be radiated from
cabinet)
<Caution>
When calculating the effective heat
radiation area, do not include the parts
that contact other objects.
(3) Points of caution for heat radiation
countermeasures when designing
mounting state
Consider convection in cabinet
(eliminate heat spots)
Collect hot air at suction port in heat
exchanger panel.
(4) Evaluation standards for internal
temperature rise distribution data
T (average value) 10°C
Tmax (maximum value) 15°C
R (inconsistency Tmax Tmin) 6°C
(Evaluate existence of heat spots)
Refer to "Section 3.1 General Specifications" for the heating value of each unit.
With the operation box, heat could accumulate at the top of the control unit, so install a circulation fan.
Install a circulation fan in the panel when the following conditions are not satisfied.
Evaluation standards for internal temperature rise distribution data
T (average value) 10°C
Tmax (maximum value) 15°C
Procedures for heat design and verification
Example of heat radiation countermeasures
Calculate total heat generation of each
mounted unit (W)
Comparison of W and W1
WW1
Collection of internal temperature rise
distribution data
Mounting design
Improvements
Completion
Selection of heat exchanger
Evaluation
W>W1
T10°C
T>10°C
Calculate cabinet’s cooling capacity
(W1)