Operation by the start command from the operation panel
(PU operation mode)
4
DRIVE THE MOTOR
60Hz for the RH, 30Hz for the RM, 10Hz for the RL are not output when they are
turned on ... Why?
Check for the setting of Pr. 4, Pr. 5, and Pr. 6 once again.
Check for the setting of Pr. 1 "maximum frequency" and Pr. 2 "minimum
frequency" once again. (Refer to page 47.)
Check that Pr. 60 "RL terminal function selection" = "0", Pr. 61 "RM terminal
function selection" = "2", Pr. 62 "RH terminal function selection" and Pr. 59
"remote function selection" = "0". (all are factory setting)
[RUN] lamp is not lit ... Why?
Check that wiring is correct. Check the wiring once again.
Check for the Pr. 79 setting once again. (Pr. 79 must be set to "4".)
(Refer to page 47)
Change the frequency of the terminal RL, RM, and RH. ...How?
Refer to page 47 to change the running frequency at each terminal in Pr. 4
"multi-speed setting (high speed)", Pr. 5 "multi-speed setting (middle speed)",
and Pr. 6 "multi-speed setting (low speed)".
Turn on the low speed switch (RL).
The output frequency
increases to 10Hz according
to Pr. 7 "acceleration time".
Turn off the low speed switch (RL).
The output frequency
decreases to 0Hz according
to Pr. 8 "deceleration time".
Low speed
Low speed
9.
10.
11.
Turn off the start switch .
RUN turns off.
RUN
PU
EXT
PU
EXT
RUN
PU
EXT
STOP
RESET
RUN
Flickering
STOP
RESET
7.
Press twice to choose the
monitor/frequency monitor.
Mode/monitor check
MODE
Press the start switch .
RUN flickers.
When the frequency command is
not given, it flickers.
MODE
8.
RUN
RUN
RUN
PU
EXT
RUN
PU
EXT
Flickering