PAR-FL32MA PAR-FA32MA PAR-SA9FA
(4-way Cassette signal receiver)
Wireless remote controller PAR-FL32MA / PAR-FA32MA
Example of system configuration
Correspondence table
• No need to configure addresses for group
operation.
• Lit LED keeps you informed of operation -
blinking even gives you the error code via
the number of blinks.
• Can be used with the MA remote controller.
*When used in group configurations, wiring
between indoor units is required.
*Combining ME remote controller and/or
LOSSNAY remote controller in a group is not
possible.
• LCD temperature setting and display in 1˚C
/1˚F increments.
• Dimensions:58(W) x 159(H) x 19(D) mm
:2.28(W) x 6.26(H) x 0.75(D) in.
Signal
receiving
unit
Non-polarized
2-wire
Non-
polarized
2-wire
Wireless
remote
controller
Signal
receiving
unit
Wireless
remote
controller
PMFY-P VBM
PLFY-P VCM/ VLMD
PCFY-P VKM
PKFY-P VHM/VKM
PFFY-P VKM
PEFY-P VMR-E-L/R/ VMH
PFFY-P VLEM/VKM/VLRM/VLRMM
PEFY-P VMS1(L)
PEFY-VMA(L)
PLFY-P VBM-E
PKFY-P VBM-E
PAR-FA32MA PAR-FA32MA PAR-SA9FA
PAR-FL32MA
receiver transmitter
PAR-FA32MA
PAR-SA9FA-E
Built-in
Signal
receiving
unit
PAR-SA9FA
Wireless
remote
controller
Page24
Remote Controller
PAC-YT51CRB
Simple remote controller PAC-YT51CRB (MA)
Wired ME remote controller PAR-F27MEA
Example of system configuration
• This remote control requires non-polar wiring to only one
indoor unit.
• Group operation over multiple outdoor units is possible.
Grouping can be changed without re-wiring, which makes
dividing rooms for tenants easier.
• Timer operation
*Daily timer operation of one ON/OFF setting everyday
*Auto-off timer : 0:30, 1:00, 1:30, 2:00...4:00
*The setting is kept in nonvolatile memory.
• Function lock
All functions or all functions except ON / OFF can be selected.
• Set temperature range limit
• Interlock setting and operation of LOSSNAY
Dimensions:130(W) x 120(H) x 19(D) mm
:5-1/8(W) x 4-23/32(H) x 3/4(D) in.
• LCD temperature setting and display in 2˚F increments.
• Control: START/STOP, room temperature, fan speed, and
operation mode
The only wiring required is cross-over wiring based on
two-wire signal lines.
• Room temperature sensors are built-in.
• LCD temperature setting and display in 1˚C /1˚F incre-
ments.
• Set temperature range limit
• Can operate all types of indoor units
*Since this controller has limited functions, it should always be
used in conjunction with standard controller or centralized
controller.
Dimensions:70(W) x 120(H) x 41(D) mm
:2-3/4(W) x 4-23/32(H) x 1-5/8(D) in.
Individual
Remote Controller
ME R/C ME R/C
Simple
MA R/C
Simple
MA R/C
Example of system configuration
Centralized
controller
24VDC
Power supply unit
(PAC-SC51KUA)
Page23