Note:
1 Nominal cooling conditions
Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
2 Nominal heating conditions
Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation.
PURY-P YSHM-A(-BS)
OUTDOOR UNIT
R2 Series
Specifications
Set name
Power source
Cooling capacity
(Nominal)
Temp.
range of
cooling
Heating capacity
(Nominal)
Temp.
range
of heating
Indoor unit
connectable
Sound pressure level
(measured in anechoic room)
Diameter of
refrigerant pipe
Model
External finish
External dimension H W D
Net weight
Heat exchanger
Compressor
FAN
Protection
Refrigerant
Pipe between
unit distributor
Optional parts
Power input
Current input
COP (kW/kW)
Indoor
Outdoor
Power input
Current input
COP (kW/kW)
Indoor temp.
Outdoor temp.
Total capacity
Model/Quantity
High pressure
Low pressure
Type
Starting method
Motor output
Air flow rate
Type Quantity
Motor output
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Type Original charge
High pressure
Low pressure
kW
BTU/h
kW
A
W.B.
D.B.
kW
BTU/h
kW
A
D.B.
W.B.
dB<A>
mm(in.)
mm(in.)
mm
in.
kg(lbs)
kW
m
3
/min
L/s
cfm
kW
mm(in.)
mm(in.)
1
1
2
2
PURY-P750YSHM-A(-BS) PURY-P800YSHM-A(-BS)
PURY-P400YHM-A(-BS)PURY-P350YHM-A(-BS)
1,710(1,650 without legs) 1,220 760
67-3/8(65 without legs) 48-1/16 29-15/16
265 (584)
10.5
225
3,750
7,945
Propeller fan 1
0.92
R410A 11.8kg (26 lbs)
PURY-P400YHM-A(-BS)
1,710(1,650 without legs) 1,220 760
67-3/8(65 without legs) 48-1/16 29-15/16
265 (584)
10.5
225
3,750
7,945
Propeller fan 1
0.92
R410A 11.8kg (26 lbs)
PURY-P400YHM-A(-BS)
Pre-coated galvanized steel sheets (+ powder coating for-BS type) <MUNSELL 5Y 8/1>
85.0
290,000
27.86
47.0-44.6-43.0
3.05
95.0
324,100
26.36
44.4-42.2-40.7
3.60
63.5
ø28.58 (ø1-1/8) Brazed
ø34.93 (ø1-3/8) Brazed
90.0
307,100
29.75
50.2-47.7-45.9
3.02
100.0
341,200
27.64
46.6-44.3-42.7
3.61
64
ø28.58 (ø1-1/8) Brazed
ø34.93 (ø1-3/8) Brazed
15 ~ 24˚C (59 ~ 75˚F)
- 5 ~ 43˚C (23 ~ 109˚F)
3-phase 4-wire 380-400-415V 50/60Hz
15 ~ 27˚C (59 ~ 81˚F)
-20 ~ 15.5˚C (-4 ~ 60˚F)
50 ~ 150% of outdoor unit capacity
P15 ~ P250 / 2 ~ 50 (Connectable branch pipe number is max. 48.)
Salt-resistant cross fin & copper tube
Inverter scroll hermetic compressor
Inverter
1,710(1,650 without legs) 1,220 760
67-3/8(65 without legs) 48-1/16 29-15/16
265 (584)
10.3
225
3,750
7,945
Propeller fan 1
0.92
R410A 11.8kg (26 lbs)
ø19.05 (ø3/4) Brazed
ø28.58 (ø1-1/8) Brazed
1,710(1,650 without legs) 1,220 760
67-3/8(65 without legs) 48-1/16 29-15/16
265 (584)
10.5
225
3,750
7,945
Propeller fan 1
0.92
R410A 11.8kg (26 lbs)
ø22.2 (ø7/8) Brazed
ø28.58 (ø1-1/8) Brazed
High pressure sensor, High pressure switch 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
Outdoor Twinning kit : CMY-R200VBK
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J
Main BC controller : CMB-P1016V-HA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
3
3
ø22.2 (ø7/8) Brazed
ø28.58 (ø1-1/8) Brazed
Page122
Outdoor Unit
PURY-P YSHM-A(-BS)
OUTDOOR UNIT
R2 Series
Specifications
Set name
Power source
Cooling capacity
(Nominal)
Temp.
range of
cooling
Heating capacity
(Nominal)
Temp.
range
of heating
Indoor unit
connectable
Sound pressure level
(measured in anechoic room)
Diameter of
refrigerant pipe
Model
External finish
External dimension H W D
Net weight
Heat exchanger
Compressor
FAN
Protection
Refrigerant
Pipe between
unit distributor
Optional parts
Power input
Current input
COP (kW/kW)
Indoor
Outdoor
Power input
Current input
COP (kW/kW)
Indoor temp.
Outdoor temp.
Total capacity
Model/Quantity
High pressure
Low pressure
Type
Starting method
Motor output
Air flow rate
Type Quantity
Motor output
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Type Original charge
High pressure
Low pressure
kW
BTU/h
kW
A
W.B.
D.B.
kW
BTU/h
kW
A
D.B.
W.B.
dB<A>
mm(in.)
mm(in.)
mm
in.
kg(lbs)
kW
m
3
/min
L/s
cfm
kW
mm(in.)
mm(in.)
1
1
2
2
PURY-P650YSHM-A(-BS) PURY-P700YSHM-A(-BS)
PURY-P350YHM-A(-BS)PURY-P300YHM-A(-BS)
1,710(1,650 without legs) 920 760
67-3/8(65 without legs) 36-1/4 29-15/16
240 (529)
8.2
185
3,083
6,532
Propeller fan 1
0.92
R410A 10.5kg (24 lbs)
ø19.05 (ø3/4) Brazed
ø22.2 (ø7/8) Brazed
PURY-P300YHM-A(-BS)
1,710(1,650 without legs) 1,220 760
67-3/8(65 without legs) 48-1/16 29-15/16
265 (584)
10.5
225
3,750
7,945
Propeller fan 1
0.92
R410A 11.8kg (26 lbs)
ø22.2 (ø7/8) Brazed
ø28.58 (ø1-1/8) Brazed
PURY-P400YHM-A(-BS)
Pre-coated galvanized steel sheets (+ powder coating for-BS type) <MUNSELL 5Y 8/1>
73.0
249,100
22.80
38.4-36.5-35.2
3.20
81.5
278,100
22.55
38.0-36.1-34.8
3.61
62.5
ø28.58 (ø1-1/8) Brazed
ø28.58 (ø1-1/8) Brazed
80.0
273,000
24.72
41.7-39.6-38.2
3.23
88.0
300,300
24.30
41.0-38.9-37.5
3.62
63
ø28.58 (ø1-1/8) Brazed
ø34.93 (ø1-3/8) Brazed
15 ~ 24˚C (59 ~ 75˚F)
- 5 ~ 43˚C (23 ~ 109˚F)
3-phase 4-wire 380-400-415V 50/60Hz
15 ~ 27˚C (59 ~ 81˚F)
-20 ~ 15.5˚C (-4 ~ 60˚F)
50 ~ 150% of outdoor unit capacity
P15 ~ P250 / 2 ~ 50 (Connectable branch pipe number is max. 48.)
Salt-resistant cross fin & copper tube
Inverter scroll hermetic compressor
Inverter
1,710(1,650 without legs) 920 760
67-3/8(65 without legs) 36-1/4 29-15/16
240 (529)
8.2
185
3,083
6,532
Propeller fan 1
0.92
R410A 10.5kg (24 lbs)
ø19.05 (ø3/4) Brazed
ø22.2 (ø7/8) Brazed
1,710(1,650 without legs) 1,220 760
67-3/8(65 without legs) 48-1/16 29-15/16
265 (584)
10.3
225
3,750
7,945
Propeller fan 1
0.92
R410A 11.8kg (26 lbs)
ø19.05 (ø3/4) Brazed
ø28.58 (ø1-1/8) Brazed
High pressure sensor, High pressure switch 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
Outdoor Twinning kit : CMY-R100VBK
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J
Main BC controller : CMB-P108, 1010, 1013, 1016V-GA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
Outdoor Twinning kit : CMY-R200VBK
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J
Main BC controller : CMB-P1016V-HA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
Note:
1 Nominal cooling conditions
Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
2 Nominal heating conditions
Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation.
3
3
Page121