23
PERFORMANCE DATA HEAT operation at Rated frequency
MUZ-HC25VA
CAPACITY: 3.2 kW INPUT: 880 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10 -5 0 5 10 15 20
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 2.02 572 2.43 686 2.85 774 3.26 836 3.68 889 4.06 915 4.48 933
21 1.92 616 2.30 730 2.72 810 3.10 871 3.52 915 3.90 942 4.30 977
26 1.73 660 2.14 774 2.53 854 2.94 915 3.36 959 3.74 986 4.16 1012
MUZ-HC35VA MUZ-HC35VAB
CAPACITY: 3.6 kW INPUT: 995 W
INDOOR
DB (°C)
OUTDOOR WB (°C)
-10 -5 0 5 10 15 20
Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT Q INPUT
15 2.27 647 2.74 776 3.20 876 3.67 945 4.14 1005 4.57 1035 5.04 1055
21 2.16 697 2.59 826 3.06 915 3.49 985 3.96 1035 4.39 1065 4.84 1104
26 1.94 746 2.41 876 2.84 965 3.31 1035 3.78 1085 4.21 1114 4.68 1144
NOTE Q : Total capacity (kW) INPUT : Total power input (W) DB: Dry-bulb temperature WB: Wet-bulb temperature